• 제목/요약/키워드: Passive Filter

검색결과 359건 처리시간 0.025초

전력품질 개선을 위한 수동필터 모니터 시스템에 관한 연구 (A Study on the Monitoring System of Passive Filter to Improve Power Quality)

  • 유재근;이상익;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.89-91
    • /
    • 2007
  • In this paper, we developed DSP based control system to automatically open and close passive filter, which is used to reduce harmonics, according to operating condition of loads. Passive filter control system automatically open and close each branch of filter according to working conditions of loads by sending signals to open and close installation of passive filter after measuring and monitoring voltage, current, harmonics, reactive power, power factor and so on. We verified it's performance by connecting control system with passive filter in the power line using the 100[HP] d.c. motor drive, opening and closing passive filter according to operation condition of motor, and measuring harmonics and reactive power, etc.

  • PDF

3상 정류기부하에 대한 수동 고조파필터의 해석 및 설계 (Analysis and Design of a Passive Harmonic Filter for a Three-Phase Rectifier)

  • 조영식;차한주
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.316-322
    • /
    • 2009
  • This paper presents an analytical design method of a passive harmonic filter for a three-phase diode rectifier and uses a new transfer function approach in the analysis and design. The transfer function approach derives an analytical formulation of an utility system including passive filters with a basis of Laplace transform and provides a graphical formulation so that a visualized insight into an interaction between individual filter and system response can be attainted. Harmonic impedance, voltage division and current division transfer function are used as a design tool, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. A simple five-step design procedure is introduced in the filter design, which consists of system analysis, selection of PCC(Point of Common Coupling), filter specification calculation, appropriate filter design for system and filter implementation. Philosophy governing the design procedure is based on a numerical/graphical iterative solution, trial and error with visualization feed-back based on "algebra on the graph". Finally, performance of the designed passive harmonic filter is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th harmonics are decreased within IEEE-519 distortion limits, respectively.

단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구 (A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters)

  • 조영식;차한주
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

고조파 저감을 위한 수동필터의 제어시스템에 관한 연구 (A Study on the Control System of Passive Filter to Reduce Harmonics)

  • 전정채;유재근;이상익
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.124-130
    • /
    • 2004
  • 본 논문에서는 고조파 저감을 위해 사용하는 수동필터를 부하의 운전조건에 따라 자동으로 개$.$폐할 수 있는 DSP 기반의 제어시스템을 개발하였다. 수동필터 제어시스템은 부하에서 발생하는 전압, 전류, 고조파, 무효전력, 역률 등을 측정 및 감시하여 수동필터 개ㆍ폐 장치에 신호를 보내어 부하의 운전조건에 따라 필터의 각 분로를 자동으로 개$.$폐하게 된다. 이러한 제어시스템을 100마력 직류전동기 구동장치를 사용하는 계통에 수동필터와 함께 설치하고 전동기 운전조건에 따라 수동필터를 개$.$폐시키며 고조파 및 무효전력 등을 측정함으로써 성능을 입증하였다.

능, 수동센서를 이용한 수중환경에서의 표적추적필터 구조 연구 (A Study on Target Tracking Filter Architecture in Underwater Environment using Active and Passive Sensors)

  • 임영택;서태일
    • 한국군사과학기술학회지
    • /
    • 제18권5호
    • /
    • pp.517-524
    • /
    • 2015
  • In this paper, we propose a new target tracking filter architecture using active and passive sensors in underwater environment. A passive sensor for target tracking needs a bearing measurement of target. And target tracking filter for using passive sensor has the observability problem. On the other hand, an active sensor does not have the problem associated with system observability problem because an active sensor uses bearing and range measurement. In this paper, the tracking filter algorithm that could be used in the active and passive sensor system is proposed to analyze maneuvering target and to improve target tracking performance. The proposed tracking filter algorithm is tested by a series of computer simulation runs and the results are analyzed and compared with existing algorithm.

직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구 (A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter)

  • 오재훈;고수현;한윤석;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

Analysis and Design of LCL Filter with Passive Damping Circuits for Three-phase Grid-connected Inverters

  • Ahn, Hyo Min;Oh, Chang-Yeol;Sung, Won-Yong;Ahn, Jung-Hoon;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.217-224
    • /
    • 2017
  • The analysis and design process of the LCL filter with passive damping circuits for three-phase grid-connected inverter are presented based on the generalized model of LCL filter. Several types of the passive damping circuits in previous studies could be compared and analyzed by using the generalized model considering various design criteria of passive damping circuits. According to the analysis in this paper, a reasonable configuration of passive damping circuits for three-phase grid-connected inverters is proposed. The validity of the proposed design process is verified by informative simulation and experimental results.

LED 구동장치용 능동 EMI 필터의 실현 (A Study on the Active EMI Filter for LED Driver)

  • 이동호;최민환;박종연
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.62-68
    • /
    • 2015
  • Recently, LED is being used as various applications such as home lightings, work lightings and so on. EMI noise generated from LED driver have become a problem according to increase the use of LED. In this paper, Active EMI filter composed active and passive components is discribed as a method of solving a problem of EMI. The proposed filter is applied to the 160W LED load to verify performance experimentally. To compare the performance, We did an experiment using the proposed filter and the passive filter on the same 160W LED load and Driver System. As a result, The proposed Active EMI filter attenuated Conduction EMI noise better than any existing passive filter.

Unscented Kalman Filter를 이용한 원격 RF 센서 시스템 구현 (Implementation of Passive Telemetry RF Sensor System Using Unscented Kalman Filter Algorithm)

  • 김경엽;이준탁
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1861-1868
    • /
    • 2008
  • In this paper, Passive Telemerty RF Sensor System using Unscented Kalman Filter algorithm(UKF) is proposed. General Passive Telemerty RF Sensor System means that it should be "wireless", "implantable" and "batterless". Conventional Passive Telemerty RF Sensor System adopts Integrated Circuit type, but there are defects like complexity of structure and limit of large power consumption in some cases. In order to overcome these kinds of faults, Passive Telemetry RF Sensor System based on inductive coupling principle is proposed in this paper. Because passive components R, L, C have stray parameters in the range of high frequency such as about 200[KHz] used in this paper, Passive Telemetry RF Sensor System considering stray parameters has to be derived for accurate model identification. Proposed Passive Telemetry RF Sensor System is simple because it consists of R, L and C and measures the change of environment like pressure and humidity in the type of capacitive value. This system adopted UKF algorithm for estimation of this capacitive parameter included in nonlinear system like Passive Telemetry RF Sensor System. For the purpose of obtaining learning data pairs for UKF Algorithm, Phase Difference Detector and Amplitude Detector are proposed respectively which make it possible to get amplitude and phase between input and output voltage. Finally, it is verified that capacitive parameter of proposed Passive Telemetry RF Sensor System using UKF algorithm can be estimated in noisy environment efficiently.

고조파 수동필터의 설계 및 적용 (Design and Application of Harmonic Passive Filter)

  • 전정채;김재현;유재근
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5397-5402
    • /
    • 2012
  • 고조파와 관련한 전력품질저하로 발생하는 전기설비사고 및 경제적 손실은 증가하고 있다. 수동필터는 고조파 문제를 해결하는데 경제적이고 효과적이지만 많은 엔지니어들은 그들의 전력시스템과의 직병렬 공진 문제 및 고조파 증폭 문제로 인해 사용하기를 꺼려한다. 본 논문은 수동필터가 잘 설계될 경우 고조파 문제를 해결하는데 매우 유용하다는 것을 보여준다. 고조파 수동필터 설계의 방법과 과정을 서술하였다. 그리고 100HP DC 모터, 압출 기계, 에어 압력기 등과 같은 비선형 부하로 인해 고조파 문제를 갖는 계통에 적용할 수 있는 수동필터를 설계하였다. 제시된 설계 방법과 절차에 대한 검증을 실험을 통해 입증하였다.