• Title/Summary/Keyword: Peak estimation

Search Result 671, Processing Time 0.031 seconds

Peak Load Estimation of Pole-Transformer in Summer Season Considering the Cooling Load of Customer (수용가 냉방부하를 고려한 하절기 주상변압기 최대부하 추정)

  • Yun, Sang-Yun;Kim, Jae-Chul;Kim, Gi-Hyun;Im, Jin-Soon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.20-27
    • /
    • 2001
  • In this paper, we propose a method for estimating the peak load of pole-transformer in summer season considering the degree of cooling load possession in customer. The cooling load of customer is selected as the most reliable parameter of peak load in summer season. The proposed estimation method is restricted to the aspect of load management for pole-transformer. The main concept of proposed method is that the error of peak load estimation using load regression equation reduces with considering the degree of cooling load possession in customer. We propose an index for estimation of cooling load possession in each customer. The proposed index is defined as cooling load possession in customer (CLPC) and obtained from the increment of monthly electric energy. The membership function for deciding the uncertainty of cooling load possession in customer is used. The database of pole-transformer in Korea Electric Power Corporation (KEPCO) is used for case studies. Through the case studies, we verify that the proposed method reduces the error of peak load estimation than the conventional method in domestic.

  • PDF

Adjustment of Load Regression Coefficients and Demand-Factor for the Peak Load Estimation of Pole-Type Transformers (주상 변압기 최대부하 추정을 위한 부하상관계수 및 수용율 조정)

  • Yun, Sang-Yun;Kim, Jae-Chul;Park, Kyung-Ho;Moon, Jong-Fil;Lee, Jin;Park, Chang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.87-96
    • /
    • 2004
  • This paper summarizes the research results of the load management for pole transformers done in 1997-1998 and 2000-2002. The purpose of the research is to enhance the accuracy of peak load estimation in pole transformers. We concentrated our effort on the acquisition of massive actual load data for modifying the load regression coefficients, which related to the peak load estimation of lamp-use customers, and adjusting the demand-factor coefficients, which used for the peak load prediction of motor-use customers. To enhance the load regression equations, the 264 load data acquisition devices are equipped to the sample pole transformers. For the modification of demand factor coefficients, the peak load currents are measured in each customer and pole transformer for 13 KEPCO (Korea Electric Power Corporation) distribution branch offices. Case studies for 50 sample pole transformers show that the proposed coefficients could reduce estimating error of the peak load for pole transformers, compared with the conventional one.

Study of Peak Load Demand Estimation Methodology by Pearson Correlation Analysis with Macro-economic Indices and Power Generation Considering Power Supply Interruption

  • Song, Jiyoung;Lee, Jaegul;Kim, Taekyun;Yoon, Yongbeum
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1427-1434
    • /
    • 2017
  • Since the late 2000s, there has been growing preparation in South Korea for a sudden reunification of South and North Korea. Particularly in the power industry field, thorough preparations for the construction of a power infrastructure after reunification are necessary. The first step is to estimate the peak load demand. In this paper, we suggest a new peak demand estimation methodology by integrating existing correlation analysis methods between economic indicators and power generation quantities with a power supply interruption model in consideration of power consumption patterns. Through this, the potential peak demand and actual peak demand of the Nation, which experiences power supply interruption can be estimated. For case studies on North Korea after reunification, the potential peak demand in 2015 was estimated at 5,189 MW, while the actual peak demand within the same year was recorded as 2,461 MW. The estimated potential peak demand can be utilized as an important factor when planning the construction of power system facilities in preparation for reunification.

A High Speed Pitch Extraction Method Based on Peak Detection and AMDF (Peak 검출과 AMDF에 의한 고속도 음성주기 추출방법)

  • 성원용;은종관
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.4
    • /
    • pp.38-44
    • /
    • 1980
  • We present a high speed pitch estimation algorithm that is based on peak detection and average magnitude difference function (AMDF). A few pitch candidates are first estimated from the low-pass filtered (800 Hz) speech by a peak detection algorithm. AMDF values of the pitch candidatestare then calculated, and the pitch candidate that yields the minimum AMDF value is chosen as the desired pitch period. The new method requires far less computation time than other pitch estimation algorithms, while it yields fairly accurate results.

  • PDF

Development of Stream Width and Bed-slope Estimation Equations for Preparing Data for Distributed Storm Runoff Model (분포형 강우-유출모형의 하도자료 구축을 위한 하폭 및 하상경사 산정공식 개발)

  • Jung, In-Kyun;Park, Jong-Yoon;Joh, Hyung-Kyung;Lee, Ji-Wan;Kim, Seong-Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.4
    • /
    • pp.1-10
    • /
    • 2010
  • In this study, two estimation equations for preparing stream data for distributed storm runoff model were developed by analyzing the nonlinear relation between upstream flow-length and stream width, and between upstream flow-length and stream bed-slope. The equations for stream cell were tested in Chungjudam watershed (6,661 $km^2$) using KIMSTORM. Six storm events occurring between 2003 and 2008 were selected for the model calibration and verification before the test of equations. The average values of the Nash-Sutcliffe model efficiency (ME), the volume conservation index (VCI), the relative error of peak runoff rate (EQp), and the difference of time to peak runoff (DTp) were 0.929, 1.035, 0.037, and -0.406 hr for the calibrated four storm events and 0.956, 0.939, 0.055, and 0.729 hr for the two verified storm events respectively. The estimation equations were tested to the storm events, and compared the flood hydrograph. The test result showed that the estimation equation of stream width reduced the peak runoff and delaying the time to peak runoff, and the estimation equation of stream bed-slope showed the opposite results.

Heart Beat Interval Estimation Algorithm for Low Sampling Frequency Electrocardiogram Signal (낮은 샘플링 주파수를 가지는 심전도 신호를 이용한 심박 간격 추정 알고리즘)

  • Choi, Byunghun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.898-902
    • /
    • 2018
  • A novel heart beat interval estimation algorithm is presented based on parabola approximation method. This paper presented a two-step processing scheme; a first stage is finding R-peak in the Electrocardiogram (ECG) by Shannon energy envelope estimator and a secondary stage is computing the interpolated peak location by parabola approximation. Experimental results show that the proposed algorithm performs better than with the previous method using low sampled ECG signals.

Estimation of CTD and Peak-to-Peak CDV Allocation to Nodes in Domestic Region (국내영역에서 셀전달지연 추정 및 peak-to-peak CDV 노드별 할당)

  • Park, Chun-Kwan;Han, Jong-Seok
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.2
    • /
    • pp.6-12
    • /
    • 2001
  • When CBR source traffics are loaded to ATM switch and broadband network termination, CTD values of ATM switch and broadband network termination are measured and then the values of CTD in the domestic region arc estimated. The estimation values of CTD satisfy the objective of CTD in the domestic region allocated by allocation rules of 1.356. The peak-to-peak CDV allocation method based On Chernoff accumulation method is proposed and applied to the nodes of national portion. From the result of numerical analysis, the proposed method is more accurate than the equal allocation method for peak -to-peak CDV in case that the CDVs at each node and the number of ATM nodes on the path increase.

  • PDF

A Comparative Study on the Methods Estimating Wave Directional Spectrum (파향스펙트럼 추정법의 비교 연구)

  • 오병철;심재설
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.2 no.3
    • /
    • pp.119-127
    • /
    • 1990
  • Wave directional spectrum estimation methods for irregular waves were considered in this study. Until now, the Longuet-Higgins Method (LHM) initiated by Longuet-Higgins et al. (1963) has been widely used, but resolutions of the estimation were found to be low. Kobune's Maximum Entropy Method (MEM) for the estimation of wave directional spectrum, bas-ed on the entropy Principle showed higher resolutions comparing with the LHM . If the wave directional spectrum is of Delta functions, the MEM is exact in its estimation. It was also found that for a unimodal spectrum, if the Mitsuyasu's spreading coefficient is above 5, the estimation resolutions were high. In bimodal spectrum, as the angle difference between the two peaks increased, the resolution improved. The energy seems to transfer to the smoother peak in the smoothing of peak's peakedness. LHM has a tendency to estimate bimodal spectrum as a unimodal spectrum ; thus, except for its computational speed, the resolution of LHM falls far below that of MEM.

  • PDF

Harmonic Peak Picking-based MVF Estimation for Improvement of HMM-based Speech Synthesis System Using TBE Model (TBE 모델을 사용하는 HMM 기반 음성합성기 성능 향상을 위한 하모닉 선택에 기반한 MVF 예측 방법)

  • Park, Jihoon;Hahn, Minsoo
    • Phonetics and Speech Sciences
    • /
    • v.4 no.4
    • /
    • pp.79-86
    • /
    • 2012
  • In the two-band excitation (TBE) model, maximum voiced frequency (MVF) is the most important feature of the excitation parameter because the synthetic speech quality depends on MVF. Thus, this paper proposes an enhanced MVF estimation scheme based on the peak picking method. In the proposed scheme, the local peak and the peak lobe are picked from the spectrum of a linear predictive residual signal. The normalized distance between neighboring peak lobes is calculated and utilized as a feature to estimate MVF. Experimental results of both objective and subjective tests show that the proposed scheme improves synthetic speech quality compared with that of the conventional one.

Adaptive Multi-target Estimation Algorithm in an IR-UWB Radar Environment (IR-UWB 레이더 환경에서 적응형 다중 목표물 추정 알고리즘)

  • Yeo, Bong-Gu;Lee, Byung-Jin;Kim, Sueng-Woo;Youm, Mun-Jin;Kim, Kyung-Seok
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.4
    • /
    • pp.81-88
    • /
    • 2016
  • In this paper, we propose an adaptive multi-target estimation algorithm using the characteristics of signals in the IR-UWB(Impulse-Radio Ultra Wideband) radar system, which is attracting attention because it has good transparency, robustness to the indoor environment, and high precision positioning of tens of centimeters. We proposed an algorithm that estimates multiple peaks with the characteristic that the signal reflected by the target has a peak. To verify the performance of these algorithms, multiple targets were placed in front of the radar and the existing technique and the multi - target estimation algorithm were compared. The location of the targets is estimated in real time with one transmitting antenna and one receiving antenna. The number of estimates can be increased compared with the existing peak signal derivation method, and multiple targets can be derived. The conventional technique estimates only one target, which results in a mean square error of 1 while a multi - target estimation algorithm yields a result of about 0.05. The proposed method is expected to be able to apply multiple targets to the estimation and application in one IR-UWB module environment.