• Title/Summary/Keyword: Percutaneous electrical stimulation

Search Result 6, Processing Time 0.018 seconds

Wound Contraction Effects of Percutaneous Electrical Stimulation on Excision Wound Models (백서의 적출창상에 대한 피하전기자극이 창상수축에 미치는 효과)

  • Gong, Gwang-Sik;Kim, Su-Hyon;Oh, Seok;Kim, Yong-Nam;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.45-51
    • /
    • 2011
  • Purpose: This study investigated the effect of needle electrode stimulation at various frequencies on change in wound healing in excision wound rats Methods: Twenty-four Sprague-Dawley adult male rats were assigned to one of four groups: control (n=6), acupuncture group (n=6), low rate (2 Hz) percutaneous electrical stimulation group, high rate (100 Hz) percutaneous electrical stimulation group (n=6). We analyzed morphological effects by measuring the area of the excision wound, the contraction rate, and chromatic red. A digital camera and an image analysis program were used to measure and analyze the wound area,which was also used for the contraction rate. Chromatic red was obtained by calculating red, green, and blue (RGB) values of the wound area. Results: The electro acupuncture stimulation groupsshowed significant healing effects compared to the control and acupuncture groups. Conclusion: The results of this study showed that various frequencies of percutaneous electrical stimulation have a therapeutic effect on wound healing.

A portable multichannel FES system for control of paralyzed extremities (마비된 말단근육의 제어를 위한 휴대용 다중 채널의 기능적 전기자극(FES) 장치)

  • 류영재;박봉기;김영민;임영철;김하경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.90-94
    • /
    • 1992
  • A portable multichannel functional electrical stimulation(FES) system for the fine control of the paralyzed extremities in spinal cord injury patients is described. This system is composed of a stimulation data creating system, a serial communication device, a 16-bit microprocessor, D/A converter of 32 channels and a display device. Stimulation patterns are created from analytical results of integrated EMGs during motion in normal subjects and are stored in the stimulation data creating system as data files. And then the stimulation patterns are sent to the memory in the portable multichannel FES system through serial communication interfacing device. Sophisticated fine control of paralyzed extrimities was realized by transmitting multichannel stimulation patterns to percutaneous intramuscular electrodes, which stimulate the motor function of paralyzed muscle simultaneously. Advantages of this system are as follws: 1) It is possible to modify stimulation patterns in accordance with the patient's situation. 2) This system is small and light.

Effect of Percutaneous Electrical Nerve Stimulation on the Spinal Neuron Excitability in STZ-induced Diabetic Rats. (피하신경전기자극이 STZ-유도 당뇨 쥐의 척수신경원 흥분성에 미치는 효과)

  • Kim, Yang-Ho;Jeong, Jin-Gyu;Kim, Tae-Youl
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.2
    • /
    • pp.13-23
    • /
    • 2004
  • This study aimed at examining the effects of percutaneous electrical nerve stimulation(PENS) applied to different parts of the streptozotocin(STZ) induced diabetic rats on the change of glucose level and spinal neuron excitability. A total of twenty-eight SD rats, divided into four groups, were used as experiment animal. Experiment group I, the normal control group, was composed of normal rats without diabetes induction. Experiment group was composed II of the rats without any treatment after experimental diabetes induction. Experiment group III was composed of the rats with 2 Hz and $200\;{\mu}s$ of PENS to the acupuncture points related with diabetes for 20 minutes after diabetes induction. Experiment group IV was composed of the rats with 2 Hz and $200\;{\mu}s$ of PENS to the parts unrelated with diabetes for 20 minutes after diabetes induction. The results can be summarized as follow: As for glucose level, the group I showed no change within normal range, and the group III showed significant increase, compared with other groups (p<0.05). As for the change of H latency, M and H amplitude, the group III showed significant differences in decrease of latency and amplitude (p<0.05). As for Hmax/Mmax ratio, the normal and other groups showed no significant differences in decrease of amplitude. It can be concluded from the above results that PENS to the acupuncture points of the STZ-induced diabetic rats was effective for spinal neurone excitability, in particular, for those of the group with PENS to the acupuncture points. This study was conducted in the period of acute diabetes induction, and therefore, further study should be conducted in the period of chronic diabetes to research both acute and chronic diabetes.

Implantable Functional Electrical Stimulation with Inductive Power and Data Transmission System (유도전력전송방식의 이식형 기능적 전기자극)

  • Lee, Joon-Ha
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.97-106
    • /
    • 2007
  • Functional electrical stimulation (FES) has developed over the last 35 years to become a scientifically, technologically and clinically recognized field of interest in clinical medicine. FES has been applied to locomotion, grasping, ventilation, incontinence, and decubitus healing. However, all of these achievements illustrate the initial applications of FES; its true potential has not yet been realized. Recently, FES systems, which are miniaturized stimulation devices, have been utilized in the clinical setting. However, because the stimulating electrodes of the current FES devices are percutaneous electrodes, which are susceptible to wire breakage, and skin infection an implantable FES stimulating electrode has been introduced in the U.S. and Japan. In the present study, an external power supply method using radio frequency (RF) coupling and data transmission was developed for the control of the implantable FES device. In addition, we review the current understanding of FES devices and their application in clinical medicine.

Effects of Interferential Current Stimulation on the Peripheral Blood Velocity in Healthy Subjects (간섭전류자극이 말초 혈류속도에 미치는 영향)

  • Park Jang-Sung;Lee Jae-Hyoung
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.2
    • /
    • pp.37-42
    • /
    • 1999
  • The purpose of this study was to determine whether percutaneous interferential current stimulation on thoracic sympathetic ganglia with amplitude modulated frequency (AMF) $90\~100$ bps and subthreshold of muscle contraction for 10 minutes on peripheral blood flow velocity in healthy subjects. Thirty-seven healthy volunteers were assigned randomly into an experimental group (n=25) and a control group (n=12). the experimental group received interferential current stimulation with subthreshold of the muscle contraction of current at AMF $90\~100$ bps on $1st\~5th$ thoracic sympathetic ganglial region for 10 minutes. The control group received same handling and electode placement, but no current was applied. Using a Doppler blood flow meter, the radial arterial blood flow velocities and the pulse raters were determined for two-way analysis of variance for repeated measures on time and group. There were no significant difference between the two groups with respect to the changes in arterial blood flow velocity and pulse rate over the four measurement times. Interferential current stimulation did not change in mean blood flow velocity and pulse rate. We conclude that interferential current stimulation on the thoracic sympathetic ganglia, as used in this study, did not dilate peripheral artery. This results suggests that interferential current stimulation dose not alter the activtiy of sympathetic nerve.

Research Trend of Oriental Nursing in Korea (한방간호 연구동향 분석)

  • Lee, Hyang-Yeon;Cho, Kyoul-Ja;Kang, Hyun-Sook;Shin, Hye-Sook
    • Journal of East-West Nursing Research
    • /
    • v.8 no.1
    • /
    • pp.27-40
    • /
    • 2003
  • Purpose: The Purpose of this study was to analyze the trends of research related with oriental nursing. Method: 124 articles about oriental nursing from 1990 to July 2003 were analyzed according to the articles' characteristics, sources by publication period, research design, nursing intervention effect of experimental study and concept, and content of literature review. Result: 1. The number of studies related with oriental nursing has progressively increased by year from 1990, and that of articles was the highest during the period between 1995 to 1999. 2. The majority of research design were survey and correlational studies, and most of them were published in the before 2000. But experimental design were used in the after 2000. 3. Nursing intervention used in the experimental design were Dan Jeon Breathing, Qigong, Yoga, Guided Imagery, Aroma therapy, San-Yin-Jiao(SP-6) Pressure, Percutaneous Electrical Nerve Stimulation, Massage(Meridian Point, hand, foot, etc.) Chuna- Bed Exercise Program. Diet for Sasang Constitution etc. 4. The key concept of literature review articles is ki(energy), oriental nursing, health promotion, oriental medicine management of illness etc. Conclusion: The summary of the above results shows a tendency that the study has increased by year. Especially, experimental study proved affirmative effect. Besides in the literature review, inquiry of theories and practical perspective, which is necessary for the establishment of oriental nursing was introduced. However, for the establishment of oriental nursing, more experimental and qualitative studies are to be required.