• Title/Summary/Keyword: Pin gauge

Search Result 13, Processing Time 0.064 seconds

A Study on the Modeling of Screw Thread Limit Gauge using Automatic Design Program (자동설계 프로그램을 이용한 나사용 한계게이지 모델링에 관한 연구)

  • 김태호;김민주;이승수;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.595-599
    • /
    • 2002
  • In this study, we try to develop the 3D automatic design program of screw thread limit gauge. When users, who have some mechanical information, input some date, they can do 3D-modeling easily like expert. This is one of the merit in automatic design program and the automatic design program can compare screw thread limit gauge made in this study with processed the bolt and nut model. This demonstrates the effective value of automatic design model. Screw thread limit gauge of sort divide into ring gauge of measuring bolt and pin gauge of measuring nut. The new created automatic design program follows the KS.

  • PDF

Development of the Pin Type Load-cell Using Strain Gauge (Strain Gauge를 이용한 핀형 로드셀 개발)

  • Lee, Dong-Wook;Park, Min-Hyuk;Lee, Gye-Gaong;Kim, In-Hwan;Lee, Seok-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.4
    • /
    • pp.75-82
    • /
    • 2014
  • A pin-type load-cell which uses shear-type strain gauges was developed to measure the tension of a wire in a winch. A finite element analysis was performed to determine the locations of the strain gauges. All of the shear-type strain gauges were attached onto parts that undergo regularly shear stress distributions. A Wheatstone bridge circuit was used to connect each of the gauges and to measure the strains. Linearity within the 5% error range was noted when testing the pin-type load-cell.

A Study on the Design of Limit Gauge using Automatic Design Program (자동설계 프로그램을 적용한 한계게이지 설계에 관한 연구)

  • 김태호;이승수;김민주;전언찬
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.12-15
    • /
    • 2002
  • In this study, we will try to develop the 3D automatic design program of limit gauge. When users, who Have some mechanical information input some date, they can do 3D-modeling easily like expert. This is one of the merit in automatic design program and the automatic design program can compare the limit gauge made in this study with processed the bolt and nut model. This demonstrates the effective value of automatic design model. Limits gauge of sort divide into ring gauge of measuring bolt and pin gauge of measuring nut. The new automatic design program follows the KS

  • PDF

A Study on the Modeling of Limit Gauge far Measuring Axis and Hole using Automatic Design Program (자동설계 프로그램을 이용한 축 및 홀 측정용 한계게이지 모델링에 관한 연구)

  • 김성욱;이승수;김민주;김순경;전언찬
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.604-607
    • /
    • 2002
  • In this study, we will try to develop the 3D automatic design program of limit gauge. When users, who have some mechanical information, input some date, they can do 3D-modeling easily like expert. This is one of the merit in automatic design program and the automatic design program can compare the limit gauge made in this study with processed the bolt and nut model. This demonstrates the effective value of automatic design model. Limits gauge of sort divide into ring gauge of measuring bolt and pin gauge of measuring nut. The new automatic design program follows the KS.

  • PDF

A modified device for intraoral radiography to assess the distal osseous defects of mandibular second molar after impacted third molar surgery

  • Ana, Faria-Inocencio;Mercedes, Gallas-Torreira
    • Imaging Science in Dentistry
    • /
    • v.41 no.3
    • /
    • pp.115-121
    • /
    • 2011
  • Purpose : This article is to describe a modified device for intraoral radiography which was developed to obtain reproducible radiographic images for assessment of distal osseous defects of the mandibular second molar (2 Mm) after impacted third molar (3 Mm) surgery. Materials and Methods : A commercial available alignment system for posterior region was modified by adding a reference gauge pin (millimetric) and threading a hollow acrylic cylinder at the ring of the radiographic positioner to attach the X-ray collimator. The design included customized resin acrylic stent for the occlusal surface of the 2Mm in maximum intercuspal position, individualizing the biteblock positioner. Periapical radiographs were taken before and after surgical extraction of 3 Mm, employing the radiographic technique of parallelism described by Kugelberg (1986) with this modified film holder and inserting the gauge pin on the deepest bone probing depth point. Results : This technique permitted to obtain standardized periapical radiographs with a moderate to high resolution, repeatability, and accuracy. There was no difference between the measurements on the pre- and post-operative radiographs. This technique allowed better maintenance of the same geometric position compared with conventional one. The insertion of the gauge pin provided the same reference point and localized the deepest osseous defect on the two-dimensional radiographs. Conclusion : This technique allowed better reproducibility in posterior radiographic records (distal surface of 2 Mm) and more accurate measurements of radiographic bone level by the use of a millimetric pin.

A Study on the Rail Materials Technology for Subway Based on its Sliding Wear Behavior (지하철 레일의 미끄럼 마모거동을 고려한 재료설계에 대한 고찰)

  • Lee, Han-Young
    • Tribology and Lubricants
    • /
    • v.30 no.6
    • /
    • pp.364-369
    • /
    • 2014
  • To assess the wear behavior of rails against subway rail car wheels, we investigate the sliding wear behavior of pins derived from two types of rails (normal rails and heat-treated rails) against a disc derived from a subway rail car wheel, using a pin-on-disc-type tribometer. We base the sliding wear test conditions on the sliding conditions for wheel flange-rail gauge corner contact. We demonstrate the remarkable transition in the wear behavior of the pins derived from the rails, from severe wear to mild wear, as a function of the sliding distance. The wear rate of the heat-treated rail material in the running-in wear region is much lower than that of the normal rail material. Furthermore, the wear rates of the pins in the running-in wear region decrease with increasing hardness and with decreasing sliding speed. However, there is little difference between the heat-treated rail pin and the normal rail pin in the wear rate in the steady-state wear region. Stricter controls on the decarburized layer beneath the surface of rails are required to reduce the wear rate in the running-in wear region.

Sharp Edge Tool Alignment for Micro Pattern Machining (마이크로 패터닝 가공을 위한 공구 정렬에 관한 연구)

  • Park, Soon-Sub;Won, Jong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.8 no.3
    • /
    • pp.1-6
    • /
    • 2009
  • This paper presents a geometrical error compensation of tool alignment for sharp edge bite on B axis controlled machine. In precision micro patterning, bite alignment is crucial parameter for machined surface. To decrease bite alignment error, plus tilted bite from B axis center is touched to reference work piece(pin gauge) and checked the deviation from original position. Same process is repeated for maximum touch deviation value. From this touched position value, wheel alignment error in X axis and Z axis can be calculated on B axis center. Experimental results show that this compensation method is efficient to correct sharp edge bite alignment.

  • PDF

Frictional Characteristics of Silicon Graphite Lubricated with Water at High Pressure and High Temperature (고온 고압에서 물로 윤활되는 실리콘그라파이트 재질의 마찰 특성에 관한 연구)

  • Lee, Jae-Seon;Kim, Eun-Hyun;Park, Jin-Seok;Kim, Jong-In
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.151-156
    • /
    • 2001
  • Experimental frictional and wear characteristics of silicon graphite materials is studied in this paper. Those specimens are lubricated with high temperature and highly pressurized water to simulate the same operating condition for the journal bearing and the thrust bearing on the main coolant pump bearing in the newly developing nuclear reactor named SMART(System-integrated Modular Advanced ReacTor). Operating condition of the bearings is realized by the tribometer and the autoclave. Friction coefficient and wear loss are analyzed to choose the best silicon graphite material. Pin on plate test specimens are used and coned disk springs are used to control the applied force on the specimens. Wear loss ana wear width are measured by a precision balance and a micrometer. The friction force is measured by the strain gauge which can be used under high temperature and high pressure. Three kinds of silicon graphite materials are examined and compared with each other, and each material shows similar but different results on frictional and wear characteristics.

  • PDF

Development of Caliper System for Geometry PIG (지오메트리 피그용 캘리퍼 시스템 개발)

  • Yoo, H.R.;Kim, D.K.;Cho, S.H.;Park, S.H.;Park, S.S.;Park, D.J.;Koo, S.J.;Rho, Y.W.;Park, G.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.228-234
    • /
    • 2001
  • NTMS(Non-contact Tilted-angle Measuring System) is developed by using the principle that the magnetic field of an anisotropic magnet's inner space is uniform and it's possible to measure the strength of the magnetic field using a linear hall effect sensor. In order to implement the caliper system of the geometry PIG(Pipeline Inspection Gauge) which has high accuracy and proper output voltage of the hall sensor without additional driving module or a signal amplifier, it is necessary to consider the size of the magnet, the inner space and back-yoke and the position of pin-hole in the magnet. So the optimal design method of the caliper system is proposed through analysis of NTMS's magnetic field adopting a FEM(Finite Element Method). The experimental results show that the developed caliper system can be used for the geometry pig with good performances.

  • PDF

Effect of Electrode Placement on Procaine Iontophoresis (전극배치가 Procaine 이온도입에 미치는 영향)

  • Lee, Jae-Hyoung;Song, In-Young;Kook, Jee-Youn
    • Journal of Korean Physical Therapy Science
    • /
    • v.4 no.2
    • /
    • pp.399-403
    • /
    • 1997
  • The purpose of this study was to determine the efficacy of electrode placement on procaine iontophoresis. Thirty-three healthy students with an age range of 19 to 34 years, were participated in this study. The subjects were randomly assigned into 3 groups. Each subjects received iontophoresis on the proximal 1/3 of volar surface of dominant forearm with soft cotton pad($3.5{\times}3.5cm$) soaked in 2 ml of 4% procaine hydrochloride (pH 5.1) at 4 mA for 10 minutes(total current 40 mA min) of anodal DC. In transversal electrode placement(TEP) group, dispersive electrode was placed on the proximal 1/3 of dorsal surface of the forearm. In longitudinal electrode placement (LEP) group and control group, dispersive electrode were placed on the distal 1/3 of volar surface of the forearm. After procaine iontophoresis, duration of anesthesia were evaluated at five minutes intervals on five random locations in the iontophoretically area using a 21-gauge sterile hypodermic needle pressed with 1 mm invagination until return the sharp pin-pricking pain sensation. The data were ana lysed with one-way ANOVA to determine signific~nt differences between groups. The results showed significantly differences in the local anesthetic duration between the 3 groups(p<0.001). The anesthetic durations of TEP group and LEP group were significantly longer when compared with control group(p<0.05). Anesthetic durations of TEP group and LEP group were not significantly difference, but anesthetic duration of LEP group tends to longer than TEP group. In view of these results, clinicians should consider the electrode placement method when performing the iontophoresis.

  • PDF