• Title/Summary/Keyword: Pipe pitch

Search Result 49, Processing Time 0.027 seconds

Finite Element Analysis on the Stress and Displacement Characteristics of Oil Pipe (오일 파이프의 응력 및 변형거동특성에 관한 유한요소해석)

  • Kim, Chung-Kyun;Cho, Seung-Hyun
    • Tribology and Lubricants
    • /
    • v.25 no.6
    • /
    • pp.374-380
    • /
    • 2009
  • This paper presents the stress and displacement characteristics of oil pipe using the finite element analysis. Displacement in axial direction and von Mises stress of a pipe were analyzed with three design factors, which are the pipe thickness, the corrugation pitch and the corrugation height, under uniform oil pressure. The FE computed results are presented between a conventional round pipe and a rectangular pipe, which is manufactured in this study. The computed FE results show that maximum displacement in axial direction and von Mises stress of pipe are increased linearly as the oil pressure increases. Also, they are increased linearly as the corrugation pitch, corrugation height and pipe thickness increases. von Mises stress of a rectangular pipe at the edge increases sharply compared with that of a conventional round pipe. Therefore, the strength of rectangular pipe is superior to that of a conventional round pipe.

Design of Tube/Pipe Straightener for Aluminum 7001 Pipes with CAD and CAE Methods (CAD/CAE를 이용한 알루미늄 7001 소재 파이프의 교정을 위한 롤러교정기의 설계)

  • Lee, H.W.;Huh, H.;Heo, J.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.25-28
    • /
    • 2002
  • This paper is concerned with the design of roller profiles in tube/pipe straightener with both methods of Computer Aided Design and Computer Aided Engineering. Design analysis is carried out from two point of view. The one is the research in the minimization of tube pitch which was very important factor in levelling process. In order to minimize tube pitch, profiles of the roller were calculated so that the contact region between roller and tube was maximized. The other is determination of an optimum amount of intermesh for the proper progress without a jam in levelling process. Generally the jamming trouble was casued by excessive amount of intermesh in levelling process. The optimum amount of intermesh was determined through the finite element analysis.

  • PDF

Modeling of Blades to Enhance Self-Power Generation in Pipe Flow (자가발전효율 향상을 위한 유수관내 블레이드 형상의 모델링 및 해석)

  • Yeo, In-Hwan;Kim, Do-Yoon;Paik, Jong-Hoo;Lee, Young-Jin;Shin, Min-Chul;Park, Jae-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.3
    • /
    • pp.277-285
    • /
    • 2010
  • We examined the optimal shape of blades and efficiency of a self-power generator when the self-power generator using flow of the water in pipe as the power source was installed. Selected factors were the shape of blades, the number of blades, pitch angle, and the existence of separator. GAMBIT2.4 was used as a modeling program, FLUENT6.3, which is computational fluid dynamics simulation program, was used as an analytical model. In the case of a viscous model, k-epsilon standard model was chosen. As a result, when the number of blades was increased, the efficiency and maximum moment were enhanced slightly. The pitch of blades went up, and maximum moment was also increased. The optimal pitch of blade was 62.5 degree and the efficiency was increased by 30%. The efficiency was also increased when a separator was installed.

The Effects of Operating and Design Conditions on the Performance of Radiant Heating Panel (복사 난방 패널의 공급유량 및 설계변수가 성능에 미치는 영향)

  • Lee, Tae Won;Kim, Ho Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.276-285
    • /
    • 1991
  • The transient heat transfer characteristics in the radiant heating panel were predicted by numerical analysis. Thermal behaviors of panel, such as temperature distributions in panel and convective and radiative heat fluxes in panel surface with respect to time were obtained. Heating hours per day, rate of energy supplied and maximum temperature differences at panel surface were also compared for several important parameters. The performance and thermal comfort of heating panel were studied and compared for various operating and design conditions such as pipe pitch, pipe location, pipe diameter and flow rate of hot water for the purpose of producing useful data, which can be used for the test and decision of efficient operating condition of the conventional heating systems or the optimal design of the new panel heating systems.

  • PDF

Unsteady Heat Transfer Analysis of Radiant Heating Panel (복사 난방 패널의 과도 열전달 해석)

  • Lee, T.W.;Kim, H.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.191-203
    • /
    • 1992
  • To analyze the unsteady heat transfer phenomena in radiant heating panel, a mathematical model was considered. Numerical analysis for solving the governing equations was conducted by using the finite difference method with boundary-fitted meshes. Transient temperature distributions and thermal responses in heating panel were obtained for various design parameters such as pipe pitches, pipe diameters and pipe depths. Experimental results were also obtained to verify the results of calculation.

  • PDF

The Improvement of the Heat Exchanger Performance by Shape Modifieation(II) (형상변화 에 의한 열교환기 의 열전달 성능 향상 (II))

  • 노승탁;이택식;강신형;이은현;송명호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.2
    • /
    • pp.202-212
    • /
    • 1985
  • Numerical and experimental studies are presented for turbulent flows and heat transfer in annular channel with circumferential fins on the inner tube in a double pipe heat exchanger. Flow and heat transfer characteristics are periodically fully developed, and complex flow patterns are shown. Numerical calculations are executed by using modified TEACH-2E computer program based on the standard k-.epsilon. turbulence model. Mean velocity, turbulent kinetic energy, and Reynolds stress distributions are measured with the hot wire anemometer. Static pressures on the outer wall of the pipe are measured for three pitch-height ratios and several Reynolds numbers. Numerical predictions generally show reasonable results in comparison with experimental results. When the pitch-height ratio is about 5.0 and other geometric parameters are fixed in this paper, maximum heat transfer is achieved. Reattaching flow patterns appeared in this region. As the pitch between fins is increased beyond 5.0, mean Nusselt numbers are decreased and the pressure drop through one pitch almost remains.

Analysis of Turbulent Heat Transfer in a Concentric Annular Pipe with Artificial Roughness (人工조도 가 있는 二重同心圓管 의 亂流 熱傳達 解析)

  • 홍진관;이기만;최영돈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.3
    • /
    • pp.301-312
    • /
    • 1983
  • Experimental results for the variation of the flow characteristics and heat transfer coefficients in the entrance region of concentric annular pipe with artificial roughness are compared with the theoretical results by numerical analysis. In the experiments, velocity profiles, pressure gradients and heat transfer coefficients were measured with variation of the Reynolds number for the constant ratio of pitch to height at the hydrodynamic entry region. Wall temperature of inner heated pipe with constant heat flux was measured at thermal entry region after the hydrodynamically fully developed region of flow. Experimental data agree well with numerical predictions. Both results show that turbulent flow of annular pipe with artificial roughness is fully developed thermally much faster than that of smooth pipe. Nusselt number of annular pipe with roughness is much higher than that of smooth pipe. However the ratios of Nusselt number of annular pipe with artificial roughness to that of smooth pipe does not vary with Reynolds number.

A Study on the Drag Reduction Effect and Heat Transfer Enhancement of Non ionized Surfactant and Water Mixture in a Circular Pipe Flow (비이온계 계면활성제 첨가수에 대한 관내 유동저항 감소 및 열전달 촉진에 관한 연구)

  • Kim, Myoung-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.552-557
    • /
    • 2007
  • This paper has dealt with the effect of non ionized surfactant and water mixture on drag reduction and heat transfer enhancement in a circular pipe flow with experimentally. The test section was consisted of stainless steel pipe with inside diameter of 16mm. The wire coil was used to increase heat transfer in a pipe and the on ionized surfactant(Oleyl Dihydroxyethyl Amino Oxide, ODEAO) was used to reduce the drag force of water mixture with surfactant. The main parameters of this experiment were diameter and pitch of wire coil and the ratio of test section length and horizontal wire coil length. In this experiment, the acquired results were 1) Drag reduction effect existed in this ODEAO-water mixture, 2) Friction factor and heat transfer were increased with insertion the heat transfer enhancement coil, 3) With increasing of pitch ratio, heat transfer was decreased, and 4) Heat transfer was decreased by the decreasing of inserting coil diameter.

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.

Roll/Pitch Attitude Control of an Underwater Robot using Ballast Tanks (밸러스트 탱크를 이용한 수중로봇의 Roll/Pitch의 자세제어)

  • Choi, Sunghee;Do, Jinhyung;Lee, Jangmyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.8
    • /
    • pp.688-693
    • /
    • 2013
  • This paper proposes a new method on attitude control of an underwater robot by using five ABTs (Attitude Ballast Tank). A pipe is connected to the bottom of the ABTs and transfers water by a pump, while another pipe is connected to the top of the ABT to transfer air. The buoyancy center of the underwater robot can be changed by means of the water transfer. This way, the attitude of the underwater robot can be maintained and/or controlled as desired. The changes of the center of gravity and the buoyancy central are estimated by a Lagrangian function which is similar to that for an inverted pendulum. The controller in this paper is designed by modeling of the underwater robot and selecting suitable gains of a PD controller which has fast response characteristics. This paper shows the possibility of the attitude control of an underwater robot by changing the center of gravity and the buoyancy center of the robot. Moreover, experimental results verify that the controller is effective in maintaining Roll/Pitch of the underwater robot with very low power consumption.