• 제목/요약/키워드: Pipe type

검색결과 888건 처리시간 0.029초

원주방향 노치형 감육부를 가진 배관의 손상거동 평가 (Evaluation of Failure Behavior of a Pipe Containing Circumferential Notch-Type Wall Thinning)

  • 김진원;박치용
    • 대한기계학회논문집A
    • /
    • 제27권8호
    • /
    • pp.1295-1302
    • /
    • 2003
  • In order to evaluate a failure behavior of pipe with notch-type wall thinning, the present study performed full-scale pipe tests using the 102mm, Schedule 80 pipe specimen simulated notch- and circular-type thinning defects. The pipe tests were conducted under the conditions of both monotonic and cyclic bending moment at a constant internal pressure of 10 MPa. From the results. of experiment the failure mode, load carrying capacity, deformation ability, and fatigue life of a notch-type wall thinned pipe were investigated, and they were compared with those of a circular-type wall thinned pipe. The failure mode of notched pipe was similar to that of circular-type thinned pipe under the monotonic bending load. Under the cyclic bending load, however, the mode was clearly distinguished with variation in the shape of wall thinning. The load carrying capacity of a pipe containing notch-type wall thinning was about the same or slightly lower than that of a pipe containing circular-type wall thinning when the thinning area was subjected to tensile stress, whereas it was higher than that of a pipe containing circular-type thinning defect when the thinning area was subjected to compressive stress. On the other hand, the deformation ability and fatigue life of a notch-type wall thinned pipe was lower than those of a circular-type wall thinned pipe.

내설성 향상을 위한 지붕형 조립식 파이프하우스의 개발 (Development of a Gable-roofed Prefabricated Pipe-house for Improvement of Snow Endurance)

  • 양인규;남상운
    • 한국농공학회논문집
    • /
    • 제51권3호
    • /
    • pp.71-78
    • /
    • 2009
  • Pipe section of bending part at the arch type pipe-house showed an ellipse with oblateness of 0.076 on the average. Flexural rigidity of bending part decreased by average 6.3% than that of an original round shape section. The deflection of arch type pipe-house measured by model experiments showed much bigger than the result of structural analysis. In case of arch type pipe-house, we supposed that the decrease of flexural rigidity for the bending part of pipes had an effect on deflection of roof under the working load. This effect should be considered in the structural analysis. Bending resistance of gable type pipe-house used a prefabricated connector which developed in this study showed about $1.5{\sim}1.8$ times stronger than that of the existing arch type or gable type processed bending. Therefore, we supposed that the gable-roofed prefabricated pipe-house is safer than arch type or bent gable type in case of heavy snowfall. According to house scales and section properties of steel pipe in use, safe snow depths and rafter intervals were presented for design of gable-roofed prefabricated pipe-house. Their standards were established in the range of the durable models recommended by RDA, and the comparative examinations were conducted by means of structural analysis. It was evaluated that the developed greenhouse model had a high applicability in the field.

스프링형상 와이어소재를 이용한 접합동시 파이프 압출성형공정 개발에 관한 연구 (Development of a Process to Simultaneously Weld and Extrude Pipe Using a Spring Type Wire Material)

  • 구경만;김태현;진인태
    • 소성∙가공
    • /
    • 제24권5호
    • /
    • pp.317-322
    • /
    • 2015
  • A process for the concurrent welding and extruding of pipe was designed for continuous production of fin tubes. Unlike a conventional pipe extrusion, the new process is able to extrude a pipe continuously without limit of length by using spring type wire material. The current paper provides the basic research for welding during the extrusion using a spring type wire material. The object of the current study is to investigate the possibility that the spring type wire material could be extrude into a welded pipe. The appropriate extrusion ratio was selected through investigation of loads using computer simulations. As a result, experiments showed that pipe could be welded and simultaneously extruded with spring type wire material of aluminum. The tensile strength of the welded and extruded aluminum pipe can reach 80% of tensile strength of original aluminum feedstock.

루프형 세관 히트 파이프의 열전달특성에 관한 연구 (A Study on the Heat Transfer Characteristics of Loop Type Capillary Heat Pipe)

  • 윤석훈;최재혁
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.346-353
    • /
    • 2000
  • In this paper, heat transfer characteristics of a loop type capillary heat pipe were experimentally investigated for the effect of several fill charge ratios of working fluid and heat loads. This type of heat pipe consists of a heating section, a cooling section and an adiabatic section. The heat pipe used has a 0.002m internal diameter, a 0.34m length in one turn and consists of 19 turns. Heating and cooling sections each have a length of 70mm. Experiments were performed to measure the temperature distributions and the pressure variation of the heat pipe. Heat transfer performance, effective thermal conductivity, boiling heat transfer and condensation heat transfer coefficients were calculated for various operating conditions of heat pipe and it was found that heat transfer characteristics of this type heat pipe were very excellent. As shown by this experimental study, this type of heat pipe operates by oscillatory flow caused by pressure and temperature oscillations.

발사체 산화제 터널형 배관 성능시험 (Performance Test of an Oxidizer Tunnel-Type Pipe for Launch Vehicle)

  • 길경섭;한상엽;고현석;신동순;조인현
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.273-277
    • /
    • 2009
  • 본 연구에서 적용한 발사체용 산화제 터널형 배관은 액체산소를 터보펌프까지 전달하는 장치로 산화제 탱크 하부에 설치된 연료탱크를 관통하여 설치된다. 터널형 배관은 연료탱크를 우회하여 설치되는 우회 배관에 비해 무게가 절감되나 열전달 표면적이 커져 연료 탱크에 저장된 연료의 온도를 변화 시킬 수 있다. 따라서 본 연구에서는 터널형 배관의 극저온 성능시험을 통하여 배관 특성 및 연료 탱크로의 열전달 현상을 고찰하였으며, 또한 발사체에 적용가능성을 확인하였다.

  • PDF

고속 이동 판재의 자동 외관 검사를 위한 영상처리 (Image Processing Technique for an Automatic Inspection of the Surface Outlook of High Speed Moving Plate.)

  • 부광석;임성현;조현춘
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.219-219
    • /
    • 2000
  • A Plate type pipe is used for heat exchange in radiator of a vehicle. The pipe has several rooms through which water flows and heat is dissipated into outside . In the case that there are small holes, cracks or some scratches on the plate, the radiators lost their functions due to Leakage. This may result in overheating of engine in a car. Thus, we need to perform the entire inspection of the plate type pipe in advance before assembling the radiator. In manufacturing process of the plate type pipe, the productive speed is very high and that may be performed continuously. So, there is no room to perform the outlook inspection by typical image processing techniques. This paper proposes a new method to inspect the outlook surface of the plate type pipe automatically with high speed. Especially, the sequential processing technique of an algorithm which detects defects on the surfaces of the plate type pipe is proposed for line scan camera which captures line image. To evaluate the inspection performance, a series of experiments is performed.

  • PDF

열전소자와 PF Type 진동형 히트파이프를 이용한 냉.난방기에 관한 연구 (The Experimental Study on Cooling-Heating System Using Thermoelectric Module and Parallel Flow Type Oscillating Heat Pipe)

  • 김종수;임용빈;조원호
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.741-747
    • /
    • 2004
  • The purpose of this study was to develop a cooler/heater using a thermoelectric module combined with a parallel flow type oscillating heat pipe with R-142b as a work ing fluid. The experiment was performed for 16 thermoelectric modules (6 A/15 V, size: 40${\times}$40${\times}$4 mm), varying design parameters of the heat pipe (inclination angle, working fluid charging ratio, etc) . Experimental results indicate that the optimum charging ratio and the inclination angle of the parallel flow type oscillating heat pipe were 30% by volume and 30%, respectively. The maximum cooler/heater capacity were 479W (COP : 0.47) and 630W (COP : 0.9), respectively.

R141b를 이용한 루프 세관형 히트파이프의 열전달특성 (Heat Transfer Characteristics of Loop Type Capillary Heat Pipe using R141b as a Working Fluid)

  • 김훈;하승만;김탁용;전경환;최재혁;윤석훈
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.256-257
    • /
    • 2005
  • This paper has been carried out to investigate heat transfer characteristics of loop type capillary heat pipe using R141b as a working fluid. In an experiment heat load are changed from 50W to 250W and the temperature of cooling water is fixed to 20$^{circ}C$ . The heat pipe is composed of 10 turns and outer diameter of heat pipe is 3.2mm. The results show that heat transport rate of this type heat pipe using R141b as a working fluid is good.

  • PDF

자석식 자동 파이프 절단기의 정속제어와 MEMS 형 가속도계를 이용한 미끄럼 측정 (Velocity Control of Magnet-Type Automatic Pipe Cutting Machine and Measurement of Slipping Using MEMS-Type Accelerometer)

  • 김국환;이성환;임성수;이순걸
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.475-478
    • /
    • 2004
  • In this paper, a magnet-type automatic pipe cutting machine that binds itself to the surface of the pipe using magnetic force and executes unmanned cutting process is proposed. During pipe cutting process when the machine moves around the pipe laid vertical to the gravitational field, the gravity acting on the pipe cutting machine widely varies as the position of the machine varies. That is, with same driving force from the driving motor the cutting machine moves faster when it climbs down the surface of the pipe and moves slower when it climbs up to the top of the pipe. To maintain a constant velocity of the pipe cutting machine and improve the cutting quality, the authors adopted a conventional PID controller with a feedforward effort designed based on the encoder measurement of the driving motor. It is, however, impossible for the encoder at the motor to measure the absolute position and consequently the absolute velocity of the cutting machine in the case where the slip between the surface of the pipe and wheel of the cutting machine is not negligible. As an attempt to obtain a better estimation of the absolution angular position/velocity of the machine the authors proposes the use of the MEMS-type accelerometer which can measure static acceleration as well as dynamic acceleration. The estimated angular velocity of the cutting machine using the MEMS-type accelerometer measurement is experimentally obtained and it indicates the significant slipping of the machine during the cutting process.

  • PDF

마찰식 박피마늘 선별기 개발 (Development of A Friction Type Garlic Separator)

  • 박재복;김종태
    • Journal of Biosystems Engineering
    • /
    • 제19권3호
    • /
    • pp.185-193
    • /
    • 1994
  • Both the wet and dry types of garlic peeling machines are being presently used in domestic garlic processing factory, but the dry type is more popular than the wet type because of higher peeling efficiency. The peeling efficiency of these machines is estimated 50 to 80%, depending on the difference in garlic varieties, physical properties and moisture content of garlic samples. If the peeling time is increased in order to improve the peeling efficiency, the damage on the surface of peeled garlic and the consumption of electric power are also increased. This study was carried out to solve these problems in garlic peeling operation and to obtain the optimun design factor for the friction type separator. The results are summarized as follows : 1. The average friction coefficients of peeled and unpeeled garlic samples were 0.91 and 0.51. respectively, for the acrylic plate, and 0.96 and 0.51, respectively, for the stainless plate. 2. For the inclined acrylic pipe with the pipe length 90 cm, the inclined angle $39^{\circ}$ and the pipe diameter 45-55 mm, the falling time of peeled garlic samples was 0.2 sec, faster than unpeeled garlic samples. 3. For the inclined stainless pipe with the pipe length 90 cm, the inclined angle $34^{\circ}$, $39^{\circ}$ and the pipe diameter pipe 35 mm, the falling time of peeled garlic samples was 0.7 sec, slower than that with the pipe diameter 47mm. 4. The stainless pipe with the pipe length 80~90 cm, the inclined angle $39^{\circ}{\sim}40^{\circ}$ and the pipe diameter 40~50 mm was the most suitable as the material of friction pipe. 5. Experimental garlic peeling machine is composed of garlic sample feeding device, friction stainless pipe and hopper. The peeling efficiency was 81 to 96%, and the separating capacity, 600 gr/min.

  • PDF