• Title/Summary/Keyword: Pit Gauge

Search Result 6, Processing Time 0.027 seconds

Characteristics Analysis of the Winter Precipitation by the Installation Environment for the Weighing Precipitation Gauge in Gochang (고창 지점의 강수량계 설치 환경에 따른 겨울철 강수량 관측 특성 분석)

  • Kim, Byeong Taek;Hwang, Sung Eun;Lee, Young Tae;Shin, Seung Sook;Kim, and Ki Hoon
    • Journal of the Korean earth science society
    • /
    • v.42 no.5
    • /
    • pp.514-523
    • /
    • 2021
  • Using the precipitation data observed at the Gochang Standard Weather Observatory (GSWO) during the winter seasons from 2014 to 2016, we analyzed the precipitation characteristics of the winter observation environment. For this study, we used four different types of precipitation gauges, i.e., No Shield (NS), Single Alter (SA), Double Fence Intercomparison Reference (DFIR), and Pit Gauge (PG). We analyzed the data from each to find differences in the accumulated precipitation, characteristics of the precipitation type, and the catch efficiency according to the wind speed based on the DFIR. We then classified these into three precipitation types, i.e., rain, mixed precipitation, and snow, according to temperature data from Gochang's Automated Synoptic Observing System (ASOS). We considered the DFIR to be the standard precipitation gauge for our analysis and the cumulative winter precipitation recorded by each other gauge compared to the DFIR data in the following order (from the most to least similar): SA, NS, and PG. As such, we find that the SA gauge is the most accurate when compared to the standard precipitation gauge used (DFIR), and the PG system is inappropriate for winter observations.

Calibration of Gauge Rainfall Considering Wind Effect (바람의 영향을 고려한 지상강우의 보정방법 연구)

  • Shin, Hyunseok;Noh, Huiseong;Kim, Yonsoo;Ly, Sidoeun;Kim, Duckhwan;Kim, Hungsoo
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.19-32
    • /
    • 2014
  • The purpose of this paper is to obtain reliable rainfall data for runoff simulation and other hydrological analysis by the calibration of gauge rainfall. The calibrated gauge rainfall could be close to the actual value with rainfall on the ground. In order to analyze the wind effect of ground rain gauge, we selected the rain gauge sites with and without a windshield and standard rain gauge data from Chupungryeong weather station installed by standard of WMO. Simple linear regression model and artificial neural networks were used for the calibration of rainfalls, and we verified the reliability of the calibrated rainfalls through the runoff analysis using $Vflo^{TM}$. Rainfall calibrated by linear regression is higher amount of rainfall in 5%~18% than actual rainfall, and the wind remarkably affects the rainfall amount in the range of wind speed of 1.6~3.3m/s. It is hard to apply the linear regression model over 5.5m/s wind speed, because there is an insufficient wind speed data over 5.5m/s and there are also some outliers. On the other hand, rainfall calibrated by neural networks is estimated lower rainfall amount in 10~20% than actual rainfall. The results of the statistical evaluations are that neural networks model is more suitable for relatively big standard deviation and average rainfall. However, the linear regression model shows more suitable for extreme values. For getting more reliable rainfall data, we may need to select the suitable model for rainfall calibration. We expect the reliable hydrologic analysis could be performed by applying the calibration method suggested in this research.

A STUDY ON MEASUREMENT OF MINIMAL DISTANCE BETWEEN PULP CHAMBER AND CORONAL SURFACE (치수강(齒髓腔)과 치관외면(齒冠外面)과의 최단거리(最短距離)에 관(關)한 실측연구(實測硏究))

  • Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.1-4
    • /
    • 1989
  • To determine the thickness of coronal hard structure the minimal distance between pupal surface and outer surface of crown was measured by means of Bowley gauge on extracted first molars. Upper(28 teeth) and lower(24 teeth) were carefully collected from 30-39 years of age and male. The teeth were split mesio-distally through central pit. On the split surface various part which are deeply related in cavity preparation were measured (schematic drawing). The results were as follows: A : Distance from mesio-cervical enamel to pulp chamber surface. upper $2.63{\pm}0.19$(mm) Lower $2.18{\pm}0.27$(um) B : Distance from mesial chamber ceiling to mesial surface upper $2.75{\pm}0.34$ Lower $2.62{\pm}0.31$ C : Distance from mesial chamber ceiling to occlusal surface upper $3.82{\pm}0.51$ Lower $3.49{\pm}0.50$ D : Distance from distal chamber ceiling to occlusal surface upper $4.28{\pm}0.69$ Lower $3.90{\pm}0.52$ E : Distance from distal chamber ceiling to distal surface upper $2.79{\pm}0.45$ Lower $2.41{\pm}0.40$ F : Distance from disto cervical enamel to pulp chamber surface upper $2.49{\pm}0.24$ Lower $2.39{\pm}0.25$.

  • PDF

The Prediction of Self-life on Functional Beverage (기능성 음료의 유통기간 예측)

  • Lee Gee-Dong;Kim Jung-Ok;Kim Min-Sun;Lee Kang-Pyo
    • Food Science and Preservation
    • /
    • v.13 no.2
    • /
    • pp.154-160
    • /
    • 2006
  • Shelf-life of functional beverage for the purpose of body fat reduction during storage was estimated at different temperatures. To estimate quality change of functional beverage, vacuum gauge, sugar concentration pit acidify, Hunter's color value, browning color intensity, total cell count and sensory evaluation were measured periodically. Vacuum gauge, sugar concentration pH and acidity were little changed and total cell count was not detected. By using the correlation coefficient between sensory evaluation and physicochemical properties, b-value was chosen for quality index of functional beverage. $Q_{10}-values$ for shelf-life were in the range of $2.13{\sim}2.59$. When sensory evaluation was 2.5 at $50^{\circ}C$, storage period was 6.83 weeks. And shelf-life calculated by $Q_{10}-values$ were 73.89, 34.21 and 13.21 weeks in $20^{\circ}C,\;30^{\circ}C\;and\;40^{\circ}C$, respectively.

A STUDY ON MORPHOLOGY AND SIZE OF CLINICAL CROWN OF PERMANENT MANDIBULAR MOLAR IN KOREAN ADULT (한국 성인의 하악대구치 임상치관의 형태와 크기에 관한 연구)

  • Oh, Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.242-255
    • /
    • 1999
  • The purpose of this study was to estimate the morphology and the size of permanent mandibular molar in Korean Adult. The 100 dental college students with a normal dentition and without any dental prosthesis and severe caries were selected for this study The subjects were taken impression to make study model. On the study model, the 5 dentists measured those sizes and estimated morphological structures with a calipers, a Boley gauge and a protractor. The results were as follows; 1. The clinical crown height, width, thickness and the other anatomical structures had symmetrical relationship between the left and right mandibular molar. 2. In the clinical crown height aspect, the buccal crown heights always were higher than the lingual crown height. The heights of the each surface, the buccal or lingual surface, were gradually decreased from the 1st molar to the 2nd molar and the difference on the buccal surface was higher than that on the lingual surface. 3. In the clinical crown width aspect, the mesiodistal measurement of the mandibular 1st molar was higher than that of the mandibular 2st molar. 4. In the clinical crown thickness aspect, the mesial buccolingual measurement was highest on the mandibular 1st molar and the distal buccolingual distance was lowest on the mandibular 2nd molar. This distal thickness of the mandibular molar always was higher than that of the mesial half. 5. The well-developed mesiobuccal groove of the 1st molar was observed more often than that of the 2nd molar. The buccal pit was also observed more frequently at the 1st molar, but the frequency(35%) was not high. 6. The occlusal type according to the number of cusp was almost 5-cusp(98%) in the 1st molar and was also 5-cusp(63%) in the 2nd molar. The frequency of the 6th cusp was 31% in the 1st molar and was 22% in the 2nd molar. The frequency of the 7th cusp was below 2of in the both teeth. 7. In the buccolingual intercuspal distance aspect of the mesial and distal half, the intercuspal distance of distal half was higher than that of the mesial half on the 1st and 2nd molar, but the difference on the 1st molar was higher than that on the 2nd molar. 8. The difference between the widths of the buccal and lingual half was 1.5mm in the 1st molar and 0.8mm in the 2nd molar. Therefore the lingual convergency of the occlusal surface was more higher in the 1st molar. 9. On the mandibular 1st and 2nd molar, the distobuccal external angle was more acute than the mesiobuccal external angle. But the mesiobuccal internal angle was more acute than the distobuccal internal angle. 10. When the mandibular molar was a 5-cusp type, the development of the distal cusp on the 1st molar was better than that on the 2nd molar. The difference between the cusps was around 0.4mm.

  • PDF

A Study on Morphology and Size of Clinical Crown of Permanent Maxillary Molar in Korean Adult (한국 성인의 상악 대구치 임상치관의 형태와 크기에 관한 연구)

  • Cha, Kwon-Sil;Oh, Sang-Chun;Dong, Jin-Keum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.79-92
    • /
    • 2000
  • The purpose of this study was to estimate the morphology and the size of permanent maxillary molar in Korean Adult. The 100 dental college students with a normal dentition and without any dental prosthesis and severe caries were selected for this study. The subjects were taken impression to make study model. On the study model, authour three times measured those sizes and estimated morphological structures with a calipers, a Boley gauge and a protractor. The results were as follows; 1. In the maxilary first molar's clinical crown height, mesiolingual cusp height was 6.34mm, mesiobuccal cusp height was 6.05mm, distobuccal cusp height was 5.20mm. And in the maxillary second molar's clinical crown height, mesiobuccal cusp height was 5.85mm, mesiolingual cusp height was 5.71mm, distobuccal cusp height was 5.51mm, distolingual cusp height was 3.53mm. This result considered that the maxillary first molar inclined to distobuccal, and the maxillary second molar more upright than the maxillary first molar. 2. In the width of clinical crown, the maxillary first molar was 10.43mm, the maxillary second molar was 10.20mm, and the difference between the first molar's width and the second molar's width was 0.23mm. 3. The crown thickness was measured divided into mesial buccolingual half and distal buccolingual half. The mesial buccolingual half was 11.14mm, and distal buccolingual half was 10.35mm in the maxillary first molar, and in the maxilary second molar, mesial buccolingual half was 11.25mm, and distal buccolingual half was 9.72mm. This result considered that height of convergency located in mesial half of crown. 4. In the buccal groove length, total length and ratio, the maxillary first molar was 52.5%, the maxillary second molar was 50%. And the development of buccal groove in the maxillary first molar was 59% in case of the well developed buccal groove and 41% in case of the weak developed one. And frequency of buccal pit of the maxillary first molar was 12.5%. Whereas, the frequency of buccal of the well developed buccal groove in the maxillary second molar was 37% and that of the weak developed one was 63%. And frequency of buccal pit of the maxillary second molar was not seen. 5. The 3 cusp type tooth cannot be found in the maxillary first molar and the frequency of 3 cusp type tooth in the maxillary second molar was as small as 6% 6. In the case of 4 cusp type tooth, the size of distal lingual cusp molar was difference between in the maxillary first molar and in the maxillary second molar by about 1mm. 7. The intercuspal distance was similar in the maxillary first premolar and second molar. And intercuspal distanc of mesial half of the maxillary first molar and the maxillary second molar was silmillar, too. 8. The an measurement of occlusal surface in 4 cusp type tooth showed that the angle of occlusal surface between the distobuccal and mesiolingual was an obtuse angle, and the angle of occlusal surface between mesiobuccal and distolingual was an acute angle in the both cases of maxillary first and second molar. 9. The measurements of the development of Carabelli cusp showed that the frequency of the well developed one was 7% and that of the weak developed one was 56% in the maxillary first molar. And there cannot be found the well developed one and can be found 2.5% only in the case of the weak developed one in the maxillary second molar. 10. The well developed oblique ridge in the maxillary first molar showed the 100% frequency and that in the maxillary second molar showed the 85.5% frequency. The frequency of mesiomarginal ridge tubercle in the maxillary first molar was 82% and that in the maxillary second molar was 30.5%. And the frequency of distal accessory tubercle in the maxillary first molar can be seen about 19% and that in the maxillary second molar can be seen about 12%.

  • PDF