• Title/Summary/Keyword: Plate-type Polymer

Search Result 78, Processing Time 0.032 seconds

Effect of Polymer Additives on Drag Reduction for a Plate Type Heat Exchanger in OTEC Applications (고분자 첨가제에 의한 OTEC용 판형 열교환기의 마찰저항감소 효과 연구)

  • Kim, N.S.;Yoon, S.M.;Seo, T.B.;Kim, C.B.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.37-44
    • /
    • 1999
  • Experimental investigation has been carried out to determine drag reducing effects of polymer additives for a plate type heat exchanger(evaporator or condenser) in OTEC power plant applications, where the pressure drop in the heat exchangers takes up $70{\sim}80%$ of the total pumping power in the existing system. The rate of drag reduction was investigated with various polymer concentrations and mass flow rates. Experiments were undertaken for a test section in Alfa-Laval plate heat exchanger utilizing Poly Ethylene Oxide(Mw $5{\times}10^6$) as polymer additives. Concentrations of polymer additives were 5, 10, 20, 30, 40, 50, 100, 200, 400 wppm at $25^{\circ}C$ and mass flow rates were 0.6kg/s, 0.7kg/s, 0.8kg/s and 0.9kg/s in normal operating ranges for a 15kW Alfa-Laval plate heat exchanger. The maximum effects of drag reductions were found at approximately 0.7kg/s of mass flow rate. The results show that there exists the optimum mass flow rate for the plate heat exchanger to obtain maximum drag reductions. Drag reduction of 20% means considerable savings in pumping power for a large size of OTEC plant.

  • PDF

Evaluation of Mechanical Characteristic of Plate-Type Polymer in Thermal-Nanoindentation Process for Hyperfine Pit Structure Fabrication (극미세 점 구조체 제작을 위한 열간나노압입공정에서 평판형 폴리머소재의 기계적 특성 평가)

  • Lee, E.K.;Lee, S.M.;Kang, C.G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.10a
    • /
    • pp.108-111
    • /
    • 2007
  • It's important to measure quantitative properties about thermal-nano variation conduct of polymer for producing high quality components using NIL process. NanoScale indents can be used ad cells for molecular electronics and drug deliver, slots for integration into nanodevices, and defects for tailoring the structure and properties. In this study, it's to evaluate mechanical characteristic of polymer such as PMMA and PC at high temperature for manufacture of nano/micro size of polymer using indenter at high temperature. At high temperature mechanical properties of polymer have extreme variation. Because heating the polymer, it becomes softer than room temperature. In this case it is especially important to study for mechanical properties of polymer at high temperature.

  • PDF

THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES (하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구)

  • Ku, Je-Hoon;Kim, Il-Kyu;Chang, Jae-Won;Yang, Jung-Eun;Sasikala, Balaraman;Wang, Boon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.

Simulation of a Polymer-Water Adsorption Refrigerator using Plate-Type Adsorption Heat Exchangers (판형 흡착열교환기를 사용한 폴리머-물 흡착식 냉동기의 성능예측)

  • Kim, Dong-Seon;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.94-102
    • /
    • 2015
  • A hydroscopic polymer is used as the adsorbent in an adsorption refrigeration system. A pair of plate-type heat exchangers, thinly coated with the polymer, is simulated using a two-dimensional transient model to predict performance of the system. It is predicted that the system would yield 0.57 kW SCP and 0.47 COP at $80^{\circ}C$ heating and $30^{\circ}C$ cooling temperatures. In comparison with a conventional silica gel-water system, the COP is comparable but SCP is about three times larger. The slow mass diffusion rate of the polymer should be improved for better performance.

Environmental Exposure Performance of a Panel-Type Glass-Fiber-Reinforced Polymer Composite Clamping Plate for an Improved Moveable Weir (개량형 가동보에 적용하기 위한 패널형 유리섬유보강 폴리머 복합재료 클램핑 플레이트의 환경노출 성능)

  • Yoo, Seong-Yeoul;Jeon, Jong-Chan;Shin, Hyung-Jin;Park, Chan-Gi
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.5
    • /
    • pp.73-81
    • /
    • 2017
  • The improved movable weir supplements the advantages and disadvantages of the rubber weir and the conduction gate. It consists of a stainless steel gate, air bags, and a steel clamping plate. The stainless steel gate is the main body of the weir, and the inflatable rubber sheet serves to support the steel gate. The steel clamping plate is typically in direct continuous contact with water, but this leads to corrosion issues that can reduce the life of the entire movable weir. In this study, a panel-type glass-fiber-reinforced polymer (GFRP) clamping plate was designed and fabricated. The test results showed that the flexural load of the panel-type GFRP composite clamping plate was over twice that of the wings type GFRP clamping plate. The lowest moisture absorption value was obtained upon exposure to tap water, and exposure to other solutions showed similar values. Additionally, flexural load testing after exposure to an accelerated environment found the lowest residual loads of 80.51 % and 78.50 % at 50 and 100 days, respectively, for exposure to a $CaCl_2$ solution, while exposure to other environments showed residual failure loads of over 80 % at both 50 and 100 days.

A study on Linear Pattern Fabrication of Plate-type Polymer by Using Thermal Nano Imprint Lithography Process (열간나노임프린트공정을 이용한 평판형 폴리머 소재의 선형 패턴 제작에 관한 연구)

  • Joung, Y.N.;Lee, C.S.;Youn, S.W.;Kang, C.G.
    • Transactions of Materials Processing
    • /
    • v.18 no.8
    • /
    • pp.616-624
    • /
    • 2009
  • In this work we demonstrate the hot-embossing process under different forming conditions such as forming temperature, load, and holding time in pressing, in order to determine the suitable conditions required for linear patterning on polymer plates (PC). Results showed that the replicated pattern depth increased in proportion to an increase in the forming temperature, load, and time. The reduction of the workpiece thickness increased according to the holding time in the pressing process. In the process of time, the reduction ratio of the workpiece thickness decreased due to the surface area increment of the workpiece, while the pressure on the workpiece declined. In order to reduce the bulging ratio we introduced a temperature difference between the upper and the lower punch.

Properties and coating technology of metallic bipolar plate for polymer electrolyte fuel cells (고분자전해질 연료전지용 금속분리판의 특성 및 코팅 기술)

  • Moon, Sungmo;Lee, Suyeon;Kwon, Duyoung
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.3
    • /
    • pp.133-142
    • /
    • 2022
  • This paper reviews bipolar plate materials and coatings for polymer electrolyte fuel cell. First, six roles and 10 requirements of the bipolar plate are described in detail. Secondly, type of materials for the bipolar plate and their advantages and disadvantages are mentioned. Thirdly, different metallic materials are introduced in terms of electrical and thermal conductivities, corrosion resistance, weight, strength and cost. Finally, various types of coating materials and methods were briefly reviewed.

Fabrication and Performance Evaluation of Diaphragm-type Actuators using Biocompatible polymer (생체적합형 고분자를 이용한 박막형 이동기의 제작 및 특성평가)

  • Jung, Young-Dae;Jeong, Hae-Do
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1254-1258
    • /
    • 2007
  • Electro-active polymer (EAP), one of the smart materials, is a new alternative offering ultra-precise movements and bio-compatibility. We present the results of the design, fabrication, and performance evaluation of a fabricated diaphragm-type polymer actuator using segmented polyurethane(SPU). This paper illustrates the relationship between the elastic modulus and maximum deflection as a key property of the Maxwell stress effect and also presents the relationship between the dielectric constant and maximum deflection as a key property of the electrostriction effect, especially in polymer actuators using SPU. A diaphragm-type actuator was used to induce an equation of the vertically distributed load by using a fully clamped circular plate as the boundary condition. To verify the equation, the results were compared to the data measured from load cell. In the near future, a low-cost check valves and bio-robot can be applied by its actuators.

  • PDF

A study on Linear Pattern Fabrication of Plate-type PC (PC소재의 선형 패턴 제작에 관한 연구)

  • Joung, Y.N.;Lee, E.K.;Kang, C.G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.277-280
    • /
    • 2008
  • Recently, a demand of nano/micro patterned polymer for display or biochip has been rising. Then many studies have been carried out. Nano/micro-embossing is a deformation process where the workpiece materials is heated to permit easier material flow and then forced over a planar patterned tool. In this work, the hot-emboss process is performed with different forming conditions; forming temperature, load, press hold time, to get the proper condition for linear pattern fabrication on plated-type polymers (PC). Replicated pattern depth increases in proportion to the forming temperature, load and time. Reduction of the workpiece thickness increases according to press hold time. In process of time, reduction ratio of workpiece thickness decreases because of surface area increment of the workpiece and pressure decline on it.

  • PDF