• Title/Summary/Keyword: Point electrode method

Search Result 137, Processing Time 0.046 seconds

A proposal of the electrochemical polishing method using the point electrode tools (점 전극을 이용한 전해연마법의 제안)

  • 이승훈
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.48-53
    • /
    • 1998
  • In this paper, the new electrochemical machining method is proposed for the micro unit fabrication by using the point electrode tools. The precision shape control capacity is improved by using the point electrode method. It was observed that an electric discharge phenomenon occurs during the electrochemical machining process by using the spraying and torrent type electrolyte supply method.

  • PDF

A study on the mechanism of the Electrochemical micromachining using point electrode method (점 전극을 이용한 미세전해가공 기구의 고찰)

  • 이승훈;박규열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.906-909
    • /
    • 2000
  • To improve dimension accuracy and make very small parts are one of the major purpose on the electrochemical micromachining. This paper introduce a small machine tool by using the point electrode. That has a data acquisition system for gathering applied electric condition between the gap. Point electrode on this system was made by this method as well. It was found that variable phenomena occurred through the acquired V-I curve on the process.

  • PDF

Electrochemical polishing method using the point electrode tools(2nd) (점 전극을 이용한 전해연마 가공특성)

  • 이승훈;박규열;양순용
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.251-255
    • /
    • 1999
  • In last paper, it was suggested electrochemical polishing method using the point electrode tools. It was aimed that Machining rate in ECM using the point electrode method should be ultimately small and also high dimension accuracy and surface integrity should be fine. In this paper, the machining characteristics were investigated by using the several types of electrolyte.

  • PDF

A Study on the micro-electrochemical phenomenon using point electrode method (점 전극을 이용한 마이크로 전해현상의 고찰)

  • 김봉규;박규열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.1093-1096
    • /
    • 2001
  • Eletrochemical phenomenon are employed in the manufacturing of micro-electrochemical machining(micro-ECM). The application of controlled electrochemical metal removal in the fabrication of microstructures and microcomponents is refer to as micro-electrochemical machining. In this paper, we introduce a new method named $\ulcorner$point-electrode electro chemical machining method$\lrcorner$ was proposed to establish micro fabrication technology by use of electrochemical machining. And we find effect of the electrochemical phenomenon in several conditions.

  • PDF

A Study on the Mechanism of Micro-ECM by Use of Point Electrode Method (점 전극을 이용한 마이크로 전해가공 기구에 관한 연구)

  • Kim, Bong-Gyu;Jeon, Jong-Up;Park, Kyu-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.8
    • /
    • pp.77-83
    • /
    • 2002
  • This research aimed at from the establishment of theory on micro electrochemical machining mechanism to the implementation of a practical fabrication system of micro parts. In detail, the mechanism of micro-ECM was investigated with potentiodynamic method and the optimal condition for micro-ECM was selected by voltage-current-time curve with potentiostatic method. From the experimental result, the micro part which has extremely fine surface could be fabricated by use of micro-ECM with point electrode method.

Micro Electrochemical Machining using Anodic Polarization Curve (양극분극곡선을 미용한 미세 전해가공)

  • 최영수;강성일;전종업;박규열
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.999-1002
    • /
    • 2002
  • In this research, the mechanism of micro-ECM was investigated with potentiodynamic method and the optimal condition for micro-ECM was selected by voltage-current-time curve with potentiostatic method. From the experimental result. it was confirmed that anodic voltage curve could be used very effectively for determining the optimal condition of micro-ECM, and the micro part which has extremely fine surface could be fabricated by use of micro-ECM with point electrode method.

  • PDF

The three-dimensional measurement and analysis for 828nm light emitted from plasma display panel by scanned point detecting method(SPDM) (Scanned point detecting method(SPDM)에 의한 플라즈마 디스플레이 패널의 828nm 광에 대한 3차원 측정과 해석)

  • 최훈영;정재완;이승걸;이석현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.284-287
    • /
    • 2000
  • We analyzed the 3-dimensional discharge characteristic in plasma display panel(PDP) cell using the 3-dimensional emission distribution of 828nm light measured by scanned point detecting method(SPDM). The emitted light distributions on the ITO electrode show the stronger light intensity near to the electrode gap than outside. Also, 828nm light is widely detected outside of the bus electrode. We consider that measurement using new SPDM is effective to analyze the discharge physics and propose the new panel structures.

  • PDF

Study on the Development of Meridian Impedance Measurement System (경락 임피던스 측정 시스템 개발에 관한 연구)

  • Lee, Woo-Cheol;Yin, Chang-Shik;Min, Kyoung-Kee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.422-429
    • /
    • 2009
  • Meridian which used as the basic theory of acupuncture treatment, is an important functional connection system of acupuncture point in oriental medicine. Yangdorak and EAV have lack of precision because of using 2-electrode method, occurring high non-uniformed current density and electrode contact status on electrode placement spot. Therefore we implemented a meridian impedance measurement system for measuring meridian impedance using 4-electrode method. In order to confirm the precision of developed system, we made an constant current characteristic experiment using standard resistor. As a results of clinical study with 18 subjects, the meridian impedance showed that reproductivity and repeatability of HT7 acupuncture point are $0.515[k{\Omega}]{\pm}0.000$(mean${\pm}$standard deviation) and $0.515[k{\Omega}]{\pm}0.002$, respectively. And reproductivity and repeatability of PC7 are $0.521[k{\Omega}]{\pm}0.000$ and $0.521[{\Omega}]{\pm}0.001$ respectively. The proposed system was stable and reliable. Therefore this study proved AC impedance method to valid in measuring meridian impedance, and also verified precision and repeatability of the proposed meridian impedance measurement system. The proposed system will serve as more effective method of measuring meridian phenomena as a bioelectric signal in clinical practice.

Measurement and Analysis of Risk Voltages in a Grounding System (접지계에서 위험전압의 측정과 분석)

  • Jin, Chang-Hwan;Park, Dae-Won;Seo, Jae-Seok;Kil, Gyung-Suk;Gil, Hyeong-Jun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3099-3103
    • /
    • 2011
  • In measurement of risk voltages; the step and touch voltage, the distance between the current electrode and the ground electrode recedes up to several hundred meters as the scale of grounding system increases. This paper dealt with the measurement method of risk voltage in a restricted space. The risk voltage was analyzed depending on the distance and the direction of the current electrode from the ground electrode in a $10[m]{\times}10[m]$ mesh grounding system. The average value of risk voltages measured at a point 20 [m] away from the current electrode was deviated below 5 [%] from that measured at 100 [m] point. Consequently, the evaluation of risk voltage of a large-scale grounding system buried in a spatially restricted place is available if the current electrode is installed in symmetry to the ground electrode.

  • PDF

A Model Study for Electrical Resistivity Method Using Three-Point Electrode Array (Three-Point 전극(電極) 배열법(配列法)을 이용(利用)한 전기(電氣) 비저항탐사(比抵抗探査) 모형연구(模型硏究))

  • Min, Kyung Duck;Kim, Chong Mi
    • Economic and Environmental Geology
    • /
    • v.14 no.3
    • /
    • pp.111-122
    • /
    • 1981
  • This study is a model analysis for an effective application of the geophysical prospecting to the investigation of geological structures or useful resources, and the purpose of it is to research a property of the electrical resistivity prospecting, especially by using a Three-Point electrode array method. In using the Three-Point electrode array method, it is theoretically assumed to choose the infinite for a distance between the two current electrodes, however it is impossible in applying to the practical field prospecting. Therefore this study was conducted for determination and presentation of a minimum appropriate distance between the two current electrodes by making a study on prospecting effect in the variation of distance between both the electrodes. In case that the ratios of the distance between the two current electrodes to that between the two potential electrodes are respectively chosen for 40, 400, 5,000, the experimental data of this study showed that the minimum appropriate distance between the two current electrodes is forty times as much as that between two potential electrodes. In order to make clear a problem about prospecting depth which is essential to the data processing, it had been chosen equally to the distance between two potential electrodes. As a result of it, it was shown that the anomaly is appeared along the position of an assumed ore body. Consequently it was found out that the prospecting depth of the Three-Point electrode array method is the same as the distance between the two potential electrodes. From the model experiment on the sheeting ore body(or linear structure) of horizontal, dipping of $30^{\circ}$, $60^{\circ}$ and vertical on the basis of above experimental condition, it was found out that the position and dip of assumed ore body could be inferred from the aspects of the equiresistivity curve. In consequence of performing out the simultaneous Normal and Reversal electrode movement, it was shown that the electrode movement of the Reversal forms the anomaly more clearly than that of Normal when the sheeting ore body is situated obliquely, therefore it could be ascertained that the electrode movement have to be performed simultaneously in the manner of Normal and Reversal. It was also exhibited that the aspect of the equiresistivity curve forms symmetrically when an assumed ore body (or linear structure) is situated horizontally or vertically, that is, symmetrically, and moreover that the aspect of the equiresistivity curve forms unsymmetrically when an assumed ore body (or linear structure) is situated obliquely. On the basis of these experimental analysis it is thought that it can be inferred from the aspect of equiresistivity curve whether an assumed ore body is obliquely situated or not.

  • PDF