• Title/Summary/Keyword: Point-to-Point

Search Result 45,912, Processing Time 0.067 seconds

Effect of Light Intensity, Temperature and $CO_2$ Concentration on Photosynthesis in Yacon(Polymnia sonchifolia Poepp.& Endl.) (광도, 온도 및 $CO_2$의 농도가 야콘의 광합성에 미치는 영향)

  • Lee, Kang-Soo;Choi, Sun-Young
    • Korean Journal of Medicinal Crop Science
    • /
    • v.9 no.3
    • /
    • pp.232-237
    • /
    • 2001
  • This study was carried out to know the effect of light intensity, temperature and $CO_2$ concentration on photosynthesis and transpiration in yacon(Polymnia sonchifolia Poepp.& Endl.). Light compensation point was ${58\;{\mu}mol\;m^{-2}\;s^{-1}}$and light saturation point was ${1708\;{\mu}mol\;m^{-2}\;s^{-1}}$. Transpiration rate was increased to about 4 mmol${m^{-2}\;s^{-1}}$ with increasing of light intensity to ${2193\;{\mu}mol\;m^{-2}\;s^{-1}}$. The optimum temperature for photosynthesis was ${24^{\circ}C}$ in air. Photosynthesis was gradually reduced as transpiration rate increased from 4 to 8 mmol ${m^{-2}\;s^{-1}}$ in different air temperature. $CO_2$ compensation point was 63 vpm and $CO_2$ saturation point was 1155 vpm and light saturation point was enhanced with increasing of $CO_2$ concentration from 350 vpm to 1300 vpm.

  • PDF

An Analysis of location of Needle Entry Point and Palpated PSIS in S1 Nerve Root Block

  • Kim, Shin-Hyung;Yoon, Kyung-Bong;Yoon, Duck-Mi;Choi, Seong-Ah;Kim, Eun-Mi
    • The Korean Journal of Pain
    • /
    • v.23 no.4
    • /
    • pp.242-246
    • /
    • 2010
  • Background: The first sacral nerve root block (S1NRB) is a common procedure in pain clinic for patients complaining of low back pain with radiating pain. It can be performed in the office based setting without C-arm. The previously suggested method of locating the needle entry point begins with identifying the posterior superior iliac spine (PSIS). Then a line is drawn between two points, one of which is 1.5 cm medical to the PSIS, and the other of which is 1.5 cm lateral and cephalad to the ipsilateral cornu. After that, one point on the line, which is 1.5 cm cephalad to the level of the PSIS, is considered as the needle entry point. The purpose of this study was to analyze the location of needle entry point and palpated PSIS in S1NRB. Methods: Fifty patients undergoing C-arm guided S1NRB in the prone position were examined. The surface anatomical relationships between the palpated PSIS and the needle entry point were assessed. Results: The analysis revealed that the transverse and vertical distance between the needle entry point and PSIS were $28.7{\pm}8.8mm$ medially and $3.5{\pm}14.0mm$ caudally, respectively. The transverse distance was $27.8{\pm}8.3mm$ medially for male and $29.5{\pm}9.3mm$ medially for female. The vertical distance was $1.0{\pm}14.1mm$ cranially for male and $8.1{\pm}12.7mm$ caudally for female. Conclusions: The needle entry point in S1NRB is located on the same line or in the caudal direction from the PSIS in a considerable number of cases. Therefore previous recommended methods cannot be applied to many cases.

Eddy Current Testing of Weldment by Plus(+) Point Probe (Plus(+) Point Probe를 이용한 용접부 와전류검사)

  • Lee, Hee-Jong;Kim, Yong-Sik;Nam, Mim-Woo;Yoon, Byung-Sik;Kim, Seok-Kon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.6
    • /
    • pp.426-432
    • /
    • 1999
  • A plus-point eddy current test(ECT) probe was developed to examine the defects on the welds of pumps, valves, and pipings which are the major components of the electric power plants, non-destructive evaluation (NDE) techniques for detecting and sizing the flaws were studied adapting this probe. Differential plus-point ECT probe is consists of two "I"-type coils crossed each other and has an advantage having a small influence on the sensitivity by lift-off variation to the conventional types of probe. The specimens with crack-like electro discharge machining(EDM) notches on the weld of type 304 stainless-steel were fabricated in order to evaluate the plus-point ECT probe response to the flaws. NDE techniques to detect and size the flaws and estimate the flaw type were established with this specimens.

  • PDF

A Study on a Lossless Compression Scheme for Cloud Point Data of the Target Construction (목표 구조물에 대한 점군데이터의 무손실 압축 기법에 관한 연구)

  • Bang, Min-Suk;Yun, Kee-Bang;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.5
    • /
    • pp.33-41
    • /
    • 2011
  • In this paper, we propose a lossless compression scheme for cloud point data of the target construction by using doubleness and decreasing useless information of cloud point data. We use Hough transform to find the horizontal angle between construction and terrestrial LIDAR. This angle is used for the rotation of the cloud point data. The cloud point data can be parallel to x-axis, then y-axis doubleness is increased. Therefore, the cloud point data can be more compressed. In addition, we apply two methods to decrease the number of cloud point data for useless information of them. One is decimation of the cloud point data, the other is to extract the range of y-coordinates of target construction, and then extract the cloud point data existing in the range only. The experimental result shows the performance of proposed scheme. To compress the data, we use only the position information without additional information. Therefore, this scheme can increase processing speed of the compression algorithm.

A Study on the New Maximum Power Point Tracking and Current Ripple Reduction of Solar Cell for the Grid-connected PV Inverter (계통연계형 태양광 인버터의 새로운 최대 전력점 추종과 태양전지의 전류리플 감소에 관한 연구)

  • Hwang, Uiseon;Kang, Moonsung;Yang, Oh
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1187-1195
    • /
    • 2013
  • Photovoltaic inverters should always track the maximum power of solar cell arrays in operation. Also, they should be irrespective of the maximum power point voltage of a wide range of solar cells in tracking the maximum power point. If the current ripple of solar cells occurs, the function of maximum power point tracking drops, and normal tracking is difficult when solar radiation or the maximum power point changes. To solve this problem, this paper proposed a new maximum power point tracking algorithm with high efficiency and an algorithm to reduce the current ripple of solar cells. According to the results from the test on 4KW grid-connected PV inverter, the efficiency of maximum power point tracking and inverter output and the total harmonic distortion of inverter output current showed 99.97%, 97.5% and 1.05% respectively. So, the inverter showed excellent performance, and made possible stable maximum power point tracking operation when the solar radiation rapidly changed from 100% to 10% and from 10% to 100% for 0.5 seconds.

The Determination of Curie Point of Bulk Gadolinium (Bulk Gadolinium의 Curie점 결정)

  • Lee, Il-Su;Lee, Ui-Wan;Lee, Sang-Yun
    • Korean Journal of Materials Research
    • /
    • v.3 no.4
    • /
    • pp.422-423
    • /
    • 1993
  • In this short note, we report the result of measurement for the ferro- to paramagnetic phase transition temperature, that is Curie point of bulk gadolinium. This note is written to give the solid validity for the previous measurement of Curie point shift of gadolinium film (1. Rhee, E. Lee and S. Lee, Kor. J. of Mat. Research,3, 3, 1993). The Curie point of bulk gadolinium is determined by measuring the resistance of sample as function of temperatures. At Curie point, we can observe the resistivity anomaly which arises due to the heat capacity difference between below and above Curie point. Finally, the curie point of bulk gadolinium is found to be 19.2${\pm}$0.$3^{\circ}C$.

  • PDF

Assessment and its control of non-point source pollution in Korea: Review (국내 비점오염 현황 및 제어방안: 총설)

  • Kang, Minwoo;Lee, Sangsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.6
    • /
    • pp.457-467
    • /
    • 2019
  • Because non-point source pollution is very closely related to hydrological characteristics, its importance is highly emphasized nowadays along with accelerating climate change. Especially for Korea, the non-point source pollution and its control are entirely depending on runoff, precipitation, drainage, land use or development, based on geographical and topographical reasons of Korea. Many studies reported the physical (e.g., apparatus- and natural-type facilities, etc.) and chemical methods (e.g., organic and inorganic coagulants, etc.) of controling non-point pollutant source pollution, however, those are needed to be reconsidered along with climate change causing the unexpected patterns and amounts of precipitation and strengthen complexity of social community. The objectives of this study are to assess recent situations of non-point source pollution in Korea and its control means and to introduce possible effective ways of non-point source pollution against climate change in near future.

A Study on the Acupuncture Point Resistance Characteristics(II) (경혈 저항특성에 관한 연구(II))

  • Kim, E.S.;Han, S.C.;Choi, T.J.;Kim, J.K.;Hur, Woong;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.69-72
    • /
    • 2001
  • In this paper, we study about a acupuncture point and a non-acupuncture point resistance characteristics for acupuncture research. For this study, we devised resistance variation measurement system. This system is consist of 4-channel skin resistance measuring parts, filters, 12bit A/D convertor, 8051 micro-controller, and personal computer The developed system insert a low current to skin and obtains voltages from standard resistor that is convected to measurement circuit in series. The obtained voltage is converted to 12bit digital signal. Therefore the converted signal is changed to skin resistance by calculation in the personal computer. As the results of experiment, the resistance of acupuncture point and non-acupuncture point are different from each other. The acupuncture point has very fast current flows than the other non- acupuncture point.

  • PDF

Chandra Archival Survey of Galaxy Clusters: X-ray Point Sources in Cool-core and Non-cool-core Clusters

  • Kim, Minsun;Kim, Eunhyeuk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.78.1-78.1
    • /
    • 2012
  • We have studied the physical properties of X-ray point sources in galaxy clusters using ~600 Chandra archival observations. The goal of this study is to investigate the density environmental effects on the physical properties of X-ray point sources by comparing the properties of X-ray point sources in galaxy clusters to those in typical blank fields. In this presentation, we show the nature of X-ray point sources which are expected to be related with galaxy clusters with different core properties. Using ~60 galaxy clusters observed with Chandra, we investigate the physical properties of X-ray point sources in cool-core and non-cool-core clusters. The cool-core clusters are known to have short central cooling time, and are characterized by low central entropy, systematic central temperature drops, and a brightest cluster galaxy at the X-ray peak. While the non-cool-core clusters have longer central cooling time, and are characterized by large central entropies and flat or centrally rising temperature profile. We show that how central core properties of galaxy clusters affect on the physical properties of X-ray point sources.

  • PDF

A Study on Improvement and Effect of Carbon Point Program for Residential Buildings in Daegu (대구광역시 주거 건축물의 이산화탄소 배출 감축을 위한 탄소포인트제의 효과 및 개선방향에 관한 연구)

  • Yeo, Myung-Kil;Jeon, Gyu-Yeob;Hong, Won-Hwa;Cho, Woong-Ho
    • Journal of the Korean housing association
    • /
    • v.23 no.4
    • /
    • pp.11-18
    • /
    • 2012
  • The amount of energy consumption in the buildings is approximately 20% of domestic energy consumption. The Carbon Point Program have been published on reduction of greenhouse gas emission in buildings under the paradigm of 'Low Carbon Green Growth'. This study focuses on the effect of 'Carbon Point Program' for residential buildings in Daegu. The amount of electricity and waterwork consumption and information of households were investigated to analyse the effect of carbon point program. The samples are situated in Deagu and are apartment in Bukgu and Suseonggu. The $CO_2$ emission is analysed by factors of energy resource and household organization between before participating and after participating in Carbon Point Program. The participation type has a difference of voluntary participation in Suseonggu and passive participation in Bukgu. Based on this investigation, average amount of $CO_2$ emission was reduced from voluntary participation households but all of them did not. To promote the effect of Carbon Point Program, this study proposes that needing the plans to raise will and activity of reducing carbon and to help participation which have disadvantage against achieving reduction.