• Title/Summary/Keyword: Pole type

Search Result 411, Processing Time 0.022 seconds

Characteristic of Moving Coil type Linear Oscillatory Actuator by Multi-Pole Permancent Magnet Arrangement (영구자석 다극 배치에 의한 가동 코일형 리니어 진도 엑츄에이터의 특성)

  • 김덕현;강규홍;홍정표;김규탁
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.273-281
    • /
    • 2001
  • In order to overcome the demerit and to improve the operation characteristics of Moving Coil type Linear Oscillatory Actuator(MC-LOA) with single-pole permanent magnet, this paper presents two models having the balanced magnetic circuit by multi-pole permanent magnet. They are short coil type with two-pole single-sided and two-ple double-sided permanent magnet. The characteristics between single-pole and multi-pole permanent magnet type MC-LOA are compared. As a result, multi-pole type MC-LOA has more merits than single-pole type about operation characteristics improvement and machine volume. The characteristics analysis is performed by their dynamic analysis composed of kinetic and electric equations and Finite Element Method(FEM). The propriety of multi-pole type MC-LOA model is verified with analysis results.

  • PDF

A Calculation of Unbalanced Current on Neutral Line in Two Step Type Pole (2단장주 중성선 불평형 전류 계산)

  • Park, Keon-Woo;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.484-485
    • /
    • 2006
  • The one step type pole and two step type pole are used in KEPCO's distribution system. The neutral current may occurs in three-phase four-wire distribution system due to unbalanced load. This paper presents neutral current both one step type pole and two step type pole in distribution system.

  • PDF

Influence of Pole Arc and Salient Pole length on Torque of Salient Pole Rotor Type Single Phase SRM (회전자 돌극형 단상 SRM에서 극호와 돌극 길이가 토오크에 미치는 영향)

  • Kim, Jun-Ho;Lee, Eun-Woong;Oh, Young-Woong;Lee, Min-Myung;Yeo, Sang-Kyom
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.107-109
    • /
    • 2001
  • The salient pole rotor type single phase SRM has a salient pole in the rotor in order to use axial direction fluxes and radial direction fluxes simultaneously. A flux linkage between the rotor and the stator are increased because of the salient pole in the rotor. But, the inductance at unaligned position and aligned position is increased together. Therefore, the length of pole are and salient pole should be selected that the inductance increment at aligned position is higher than the inductance increment at unaligned position. On this paper, we will be studied the influence of the pole arc and the salient pole length on the torque of the salient pole rotor type single phase SRM.

  • PDF

Magnetic Pole Structure of Electro-Magnet for Forming Uniform Magnetic Field (평등자계 형성용 전자석 자극 구조에 관한 연구)

  • 김정태;이승면;조현준;김훈년
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.515-518
    • /
    • 2002
  • In this study, the ellipsoidal cap type magnetic pole structure was proposed for the electro-magnet in B-H curve tracer. From the simulation for the electro-magnet without specimen, the area of effective uniform field(99% range for the central field value) was considerably increased in case of the newly proposed ellipsoidal cap type magnetic pole than that of the conventional simple-inclined cap type magnetic pole. Also, through the simulation for the electro-magnet with permanent magnet specimen(NaFe30), the optimal Positions of the magnetic field measurement sensor(Hall sensor) were found out in each case and the errors were decreased in case of the newly proposed ellipsoidal cap type magnetic pole.

  • PDF

Development of The H Type Steel Pole for 154kV Transmission Lines (154kV 송전선로용 H형 Steel Pole 개발)

  • Byun, Gang;Min, Byeong-Wook;Shin, Tai-Woo;Choi, Jin-Sung;Jiang, Moon-Myong;Song, Teak-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.433-435
    • /
    • 2003
  • As the nation's standard of living rises lately, the common interest in the environmental issue is raised and the environmental design of a transmission line is needed. When the environmental design is needed, KEPCO used a steel pole instead of a rectangular tower. A steel pole has many advantages such as simplification of a tower and less damage to the forest according to less demand of site. But the weak withstand weight of a mono type steel pole is a problem. This paper introduces an H type steel pole which improves its withstand weight, reduces a diameter of a pole from 2.6m to 1.3m and decreases joining points according to the increase of unit length of a pole from 6m to 9m.

  • PDF

The Fundamental Design Consideration of Salient Pole Rotor Type Single Phase SRM

  • Oh, Young-Woong;Lee, Eun-Woong;Kim, Jun-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.2
    • /
    • pp.22-27
    • /
    • 2001
  • Salient pole rotor type single phase switched reluctance motor is of simple and rigid structure, short shaft and simple driving circuit. Especially, the output power per unit volume of salient pole rotor structure is comparatively high because the magnetic fluxes of axial and radial direction are simultaneously used. Therefore, this motor will be used at small space and difficult maintenance situations. In this paper, the selecting method of proper pole arc, stator, and rotor dimension of salient pole rotor type single phase SRM is proposed.

Design of Salient Pole Rotor Type Single Phase SRM

  • Oh, Young-Woong;Lee, Eun-Woong;Kim, Jun-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.11B no.2
    • /
    • pp.9-14
    • /
    • 2001
  • Because salient pole rotor type single phase SRM(Switched Reluctance Motor) has a simple structure and can be use both radial and axial direction magnetic flux at the same time, its output power per unit volume is high. Therefore, the shaft length can be minimized when compared with same output motors. However, salient pole rotor is hard to design due to its complex magnetic circuit. In this paper, salient pole rotor type single phase SRM with minimized shaft length is designed and selected the most suitable dimension of rotor, stator, pole arc and salient pole.

A Study on the Effects of Neutral Current by Unbalanced Load in Two Step Type Pole using KEPCO's Distribution System (한전 배전 계통을 이용한 2단장주의 불평형 부하에 따른 중성선 전류의 영향에 관한 연구)

  • Park, K.W.;Seo, H.C.;Kim, C.H.;Jung, C.S.;Yoo, Y.P.;Lim, Y.H.;Lee, W.J.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.465-471
    • /
    • 2007
  • The one step type pole and two step type pole are used in KEPCO's distribution system. The neutral current increases in three-phase four-wire distribution system due to unbalanced load. Usually, power line and communication line are installed at contiguity by effect of topography in Korea. To this end, the damages such as electrostatic induction, electromagnetic induction and harmonic induction generated by induced voltage and current are occured in power line and communication line. This paper calculates the neutral current in KEPCO's distribution system using EMTP by composing various simulated conditions. Also, these results are verified by vector analysis.

A Study on the Detent Torque Reduction of Claw Pole Permanent Magnet Type Motor

  • Jung, Dae-Sung;Lee, Ju;Lee, Sang-Taek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.125-132
    • /
    • 2013
  • This paper has done a three-dimensional FEM analysis of the PM claw pole stepping motor. As magnetization happens in the z-axis, which does not have a constant value, three-dimensional FEM analysis is necessary for characteristic analysis of PM claw pole stepping motors. Because it is a type of permanent magnet motor, the PM claw pole stepping motor naturally has a detent torque. This torque is known to show negative effects on motor performance. To improve motor performance, reducing the detent torque is very important during the motor design. This paper applied DOE for optimization of stator pole design of the motor. Also, we compared motor performance by applying a different type of rotor shape, dividing the permanent magnet. To verify the simulation results, an experiment was done.

Neutral Current Calculation of Pole-Top Overhead Distribution Line (가공 배전선로 장주의 중성선 전류 계산)

  • Seo, Hun-Chul;Kwon, O-Sang;Kim, Chul-Hwan;Jung, Chang-Soo;Yoo, Yeon-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.7
    • /
    • pp.290-296
    • /
    • 2006
  • If the three phases are not balanced, the current in neutral wire is not zero. Then, the induced voltage can be generated in communication line. The KEPCO's rule about unbalanced current for one step type in distribution pole is a twenty percent of phase current. But the unbalanced current for two step type in distribution pole can't decide the rule because there are many different views. This paper presents the calculation and analysis technique of neutral current in distribution poles using equivalent circuit analysis and EMTP simulation.