• 제목/요약/키워드: Power Performance

Search Result 17,025, Processing Time 0.051 seconds

Performance Prediction of a Combined Heat and Power Plant Considering the Effect of Various Gas Fuels

  • Joo, Yong-jin;Kim, Mi-yeong;Park, Se-ik;Seo, Dong-kyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.2
    • /
    • pp.133-140
    • /
    • 2017
  • The performance prediction software developed in this paper is a process analysis tool that enables one to foretell the behavior of processes when certain conditions of operation are altered. The immediate objective of this research is to predict the process characteristics of combined heat and power plant under varying operating conditions. A cogeneration virtual power plant that mimics the mechanical performance of the actual plant was constructed and the performance of the power plant was predicted in the following varying atmospheric conditions: temperature, pressure and humidity. This resulted in a positive outcome where the performance of the power plant under changing conditions were correctly predicted as well as the calorific value of low calorific gas fuel such as shale gas and PNG. The performance prediction tool can detect the operation characteristics of the power plant through the performance index analysis and thus propose the operation method taking into consideration the changes in environmental conditions.

Analysis on the Qualitative Performance of a Power Split/Circulation Transmission (동력분기/순환구조 동력전달계의 정성적 성능 해석)

  • Lim, W.S.;Lee, D.J.;Lee, J.M.;Park, Y.I.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.212-223
    • /
    • 1995
  • To improve the efficiency of a power transmission system with slip elements, power split/circulation system is applied. The performance of a power split/circulation system varies widely by the change of the followings; the layout of system, the type and gear ratio of planetary gear, the performance of slip element, etc. Therefore, when one designs such a power transmission system or when one determines the economic/power mode of system, a certain performance prediction method is needed. In this study, the internal power flow pattern of a power split/circulation system is theoretically analyzed on several transmission systems. And an effective performance prediction method(so called performance locus diagram) is presented. By this method, the effects of design factors can be easily understood and the qualitative performances of system can be clearly evaluated.

  • PDF

Effect of Power Control Step Size on the Performance of the SIC Scheme in Power-Controlled DS/CDMA Systems

  • Lee, Chiho;Kim, Kiseon
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1701-1704
    • /
    • 2002
  • In this paper, we investigate the effect of power control step size on the performance of the SIC scheme in DS/CDMA systems. We investigate the average power control iteration and its standard deviation and evaluate the outage performance for several different values of power control step size. Because the SIC scheme requires fine control in the received signal power, the better outage performance is obtained fer the smaller power control step size. However, the smaller power control step size requires larger amount of power control iteration in order to make the power control converge to the steady state. Under the simulated environment, the proper power control step size is about 0.3-0.4dB from both convergence speed of power control algorithm and outage performance points of view.

  • PDF

Development of Power Performance Evaluation System using Modeling Technology (설비 모델링 기술을 이용한 발전성능평가 시스템 구성방안 연구)

  • Lee, Ji-Hoon;Lee, In-tae;Jung, Nam-Joon;Bae, Jung-Seok;An, Young-Mo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.2
    • /
    • pp.81-88
    • /
    • 2018
  • Performance evaluation of a plant to efficiently manage and maintain the performance of the plant is a very important procedure. However, since the conventional performance evaluation method is an Excel-based manual method, the preparation procedure is complicated and the versatility is poor. In this paper, we analyze the problems of the existing performance evaluation system, effectively model the equipment, calculate the missing physical properties, and improve the versatility, efficiency and accuracy of the performance evaluation through the equipment modeler which performs automatic index calculation based on this.

Performance of multi-level QAM transceiver with adaptive power control in fixed wireless channel

  • Lee, Seong-Choon;Lee, Yong-Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.533-536
    • /
    • 2000
  • We consider the design of quadrature amplitude modulation (QAM) transceivers f3r fixed wireless communications. The use of adaptive power control in the transmitter (Tx) can provide BER performance robust to fading and improved BER performance. The BER performance is evaluated by analytical and simulation results when multi-level QAM transceiver employing power control in the Tx is applied to fixed wireless channel with flat fading and frequency selective fading. The effect of power control parameters such as power control range and power control step size is investigated

  • PDF

Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant (원자력발전소 직류전원계통용 축전지 성능시험 분석)

  • Kim, Daesik;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

On Power Splitting under User-Fairness for Correlated Superposition Coding NOMA in 5G System

  • Chung, Kyuhyuk
    • International journal of advanced smart convergence
    • /
    • v.9 no.2
    • /
    • pp.68-75
    • /
    • 2020
  • Non-orthogonal multiple access (NOMA) has gained the significant attention in the fifth generation (5G) mobile communication, which enables the advanced smart convergence of the artificial intelligence (AI), the internet of things (IoT), and many of the state-of-the-art technologies. Recently, correlated superposition coding (SC) has been proposed in NOMA, to achieve the near-perfect successive interference cancellation (SIC) bit-error rate (BER) performance for the stronger channel users, and to mitigate the severe BER performance degradation for the weaker channel users. In the correlated SC NOMA scheme, the stronger channel user BER performance is even better than the perfect SIC BER performance, for some range of the power allocation factor. However, such excessively good BER performance is not good for the user-fairness, i.e., the more power to the weaker channel user and the less power to the stronger channel user, because the excessively good BER performance of the stronger channel user results in the worse BER performance of the weaker channel user. Therefore, in this paper, we propose the power splitting to establish the user-fairness between both users. First, we derive a closed-form expression for the power splitting factor. Then it is shown that in terms of BER performance, the user-fairness is established between the two users. In result, the power splitting scheme could be considered in correlated SC NOMA for the user-fairness.

An Empirical Study of the Effects of a Customer's Power on a Supplier's Customer Integration and Operational Performance Improvement (고객기업의 힘이 공급기업의 고객기업 통합활동과 운영성과 향상에 미치는 영향)

  • Hur, Daesik;Kim, Hyojin;Ahn, Kyungseon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.40 no.3
    • /
    • pp.1-21
    • /
    • 2015
  • Customer firms exercise various sources of power to influence their suppliers' behaviors or decisions. In this study we aim to examine the effects of customers' sources of power on their supplier's performance improvement. This study posits that a customer's expert, referent, and reward power positively influence a supplier's performance directly as well as indirectly through increased supplier-customer integration. On the contrary, the customer's coercive power is expected to worsen the supplier's operational performance because of increasing distrust, dissatisfaction, and conflict with the customer. Data collected from 1,229 firms from Korea, China, Hong Kong, Taiwan, and the U.S. are used to test the hypotheses. Expert power proves to be the most effective source of customer power in improving a supplier's inventory cost, delivery, and flexibility performance. In contrast, coercive power deteriorates significantly all supplier performance variables. Academic and managerial implications are presented and future research directions are also discussed.

Development of Performance Demonstration Programs for Eddy Current Data Analysis

  • Cho, Chan-Hee;Nam, Min-Woo;Yang, Seung-Han;Yang, Dong-Soon;Lee, Hee-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.3
    • /
    • pp.228-232
    • /
    • 2005
  • The Korea Electric Power Research Institute (KEPRI) has developed performance demonstration programs for non-destructive testing personnel who analyze ECT(eddy current testing) data for steam generator tubing since 2001 The purpose of these performance demonstration programs is to ensure a uniform knowledge and skill level of data analysts and contribute to safe operation of nuclear power plants. Many changes have occurred in non-destructive testing of steam generator tubing such as inspection scope, plugging criteria and qualification requirements. According to the Notice 2004-13 revised by the Ministry of Science and Technology (MOST), the analyst for steam generator tubing shall be qualified as the qualified data analyst (QDA), and the site specific performance demonstration (SSPD) program shall be implemented. KEPRI developed these performance demonstration programs and they are being successfully implemented. The analyst's performance is expected to be improved by the implementation of these programs.

A Study on the Relationship between Steam Generator Fouling and the Electric Power (증기발생기 파울링과 전기출력의 상관성 고찰)

  • Cho, Nam Cheoul;Shin, Dong Man;Kim, Yong Sik
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.2
    • /
    • pp.31-37
    • /
    • 2017
  • The heat transfer function or thermal performance is the most important function of the steam generator component in nuclear power plants. The declining of thermal performance, fouling does not affect the electric power of the nuclear power plant within a certain fouling level, but it affects the output when goes beyond the governor valve wide open of the turbine. The VWO steam pressure can be predicted through the thermal performance evaluation of steam generators in the nuclear power plant. In consideration of the fouling characteristics of the steam generator, methods of the thermal performance evaluation and fouling cases are reviewed, and also the critical VWO value is estimated through the actual thermal performance evaluation. It is necessary to apply the VWO theory based on the thermal performance of the steam generators.