• 제목/요약/키워드: Power quality

검색결과 959건 처리시간 0.163초

가정용태양광 발전설비의 전력품질 측정에 관한 연구 (Study on the Measuring of Power Quality for the Residental PV System)

  • 안재민;한운기;정진수;김선구;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2176_2177
    • /
    • 2009
  • This paper describe the power quality measuring result of the inter-connected residental PV system. The power quality measuring for inter-connected residental PV system are important to verify their performance and effect of power distribution system with inter-connected residental PV system. Also, these power quality measuring and analysis are essential to improve electrical safety. In order to evaluate influence of power distribution system with inter-connected residental PV system, we measure and analyze power quality index such as power, voltage, current, harmonic, THD, flicker index, power factor and frequency using DEWE5000.

  • PDF

보호계전기를 이용한 전기 품질 감시 기법 연구 (Power Quality Monitoring Algorithm Using the Protective Relay)

  • 최인선;이강석;최면송;임성일;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권11호
    • /
    • pp.581-588
    • /
    • 2004
  • Power qualify monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. This paper was studied on using data of the protective relay by Power Quality Monitor. This paper was proposed the wave storage condition and monitoring clauses of the protective relay as a power quality monitoring device. The protective relay will have problem to save data for PQM analysis because the protective relay memory is limited. Therefore this paper was proposed new a data compression of data got from the protective relay. This method is wave compression comparison algorithm using the DFT. The compression rate is higher than any other established method. This method can be real time storage. This algorithm is verified using the comparison among other compression rate and proved by Real Time Digital Simulator (RTDS).

Power Quality Disturbances Identification Method Based on Novel Hybrid Kernel Function

  • Zhao, Liquan;Gai, Meijiao
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.422-432
    • /
    • 2019
  • A hybrid kernel function of support vector machine is proposed to improve the classification performance of power quality disturbances. The kernel function mathematical model of support vector machine directly affects the classification performance. Different types of kernel functions have different generalization ability and learning ability. The single kernel function cannot have better ability both in learning and generalization. To overcome this problem, we propose a hybrid kernel function that is composed of two single kernel functions to improve both the ability in generation and learning. In simulations, we respectively used the single and multiple power quality disturbances to test classification performance of support vector machine algorithm with the proposed hybrid kernel function. Compared with other support vector machine algorithms, the improved support vector machine algorithm has better performance for the classification of power quality signals with single and multiple disturbances.

Coordinated Control Strategies with and without Circulating Current in Unified Power Quality

  • Feng, Xing-tian;Zhang, Zhi-hua
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1348-1357
    • /
    • 2015
  • Under traditional unified power quality conditioner (UPQC) control, a UPQC series converter (SC) is mainly used to handle grid-side power quality problems while its parallel converter (PC) is mainly used to handle load-side power quality problems. The SC and PC are relatively independent. The SC is usually in standby mode and it only runs when the grid voltage abruptly changes. In this paper, novel UPQC coordinated control strategies are proposed which use the SC to share the reactive power compensation function of the PC especially without grid-side power quality problems. However, in some cases, there will be a circulating current between the SC and the PC, which will probably influence the compensation fashion, the compensation capacity, or the normal work of the UPQC. Through an active power circulation analysis, strategies with and without a circulating current are presented which fuses the reactive power allocation strategy of the SC and the PC, the composite control strategy of the SC and the compensation strategy of the DC storage unit. Both of the strategies effectively solve the SC long term idle problem, limit the influence of the circulating current, optimize all of the UPQC units and reduce the production cost. An analysis, along with simulation andexperimental results, is presented to verify the feasibility and effectiveness of the proposed control strategies.

전기추진선박의 전력품질 개선을 위한 리튬-이온 배터리 에너지저장시스템 적용 (Lithium-ion Battery Energy Storage System for Power Quality Improvement in Electrical Propulsion Ships)

  • 구현근;서혜림;김장목
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.351-355
    • /
    • 2015
  • This paper explained the application of a lithium-ion battery energy storage system to electric propulsion ships. The power distribution in electric propulsion ships has low power quality because of the variation in the power consumption of the propulsion motor. For proper operation of the ship, the power quality needs to be improved, and the battery energy storage system is used to solve power-quality problems. The simulation models of electric propulsion ship and battery energy storage systems are constructed on MATLAB/Simulink to verify the improvement in power quality. The proposed system is applied in various scenarios of the propulsion motor state. The power quality achieved by using the battery energy storage system in both voltage and frequency satisfies the standards set by IEC-60092/101.

150kVA급 전기품질 보상기기 제어 알고리즘 설계 (The Design of control algorithm for 150kVA power quality compensator)

  • 전진흥;김지원;전영환;김호용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1070-1072
    • /
    • 2001
  • In recent years, customers and power supplies are interested in power quality. Demands of customers are change from standard quality of distribution power system to various high quality of distribution power system. so, it is necessary to apply power quality compensator, in our project, we develop the power quality compensator of 150kVA which compensates power factor and voltage sag, interruption. it is very frequently occurred power qualify problems[1,2]. As a series and shunt compensator, power quality compensator consists of two inverters with common do link capacitor bank. It compensates the current quality in the shunt part and the voltage qualify in the series part. In this paper we present the design and control algorithm of power quality compensator. As a control algorithm is implemented by digital controller, we consider sample-and-hold of signals. In this simulation, we use EMTDC/PSCAD V3.0 software which can simulate instantaneous voltage and current.

  • PDF

Modelling a Stand-Alone Inverter and Comparing the Power Quality of the National Grid with Off-Grid System

  • Algaddafi, Ali;Brown, Neil;Rupert, Gammon;Al-Shahrani, Jubran
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권1호
    • /
    • pp.35-42
    • /
    • 2016
  • Developments in power electronics have enabled the widespread application of Pulse Width Modulation (PWM) inverters, notably for connecting renewable systems to the grid. This study demonstrates that a high-quality power can be achieved using a stand-alone inverter, whereby the comparison between the power quality of the stand-alone inverter with battery storage (off-grid) and the power quality of the utility network is presented. Multi-loop control techniques for a single phase stand-alone inverter are used. A capacitor current control is used to give active damping and enhance the transient and steady state inverter performance. A capacitor current control is cheaper than the inductor current control, where a small current sensing resistor is used. The output voltage control is used to improve the system performance and also control the output voltage. The inner control loop uses a proportional gain current controller and the outer loop is implemented using internal model control proportional-integral-derivative to ensure stability. The optimal controls are achieved by using the Sisotool tool in MATLAB/Simulink. The outcome of the control scheme of the numerical model of the stand-alone inverter has a smooth and good dynamic performance, but also a strong robustness to load variations. The numerical model of the stand-alone inverter and its power quality are presented, and the power quality is shown to meet the IEEE 519-2014. Furthermore, the power quality of the off-grid system is measured experimentally and compared with the grid power, showing power quality of off-grid system to be better than that of the utility network.

Digital Signal Processor를 이용한 실시간 전력 요소와 왜율 측정 시스템 설계 (System Design for Real-Time Measuring of Power Quality and Harmonics Distortion using Digital Signal Processor)

  • 김근준;강봉순
    • 한국정보통신학회논문지
    • /
    • 제20권7호
    • /
    • pp.1283-1289
    • /
    • 2016
  • 전력은 현대 사회를 구성하는데 있어 필수적인 자원이다. 최근, 전력에 대한 수요가 급격하게 증가하였으며 전력 수요 증가는 전력 품질의 저하를 야기하였다. 현대 사회에서 전력 품질은 일반 가정과 산업 전반에 걸쳐 큰 문제를 일으킬 수 있는 중요한 요소가 되었다. 전력 품질 문제를 예방하기 위해서는 전력 품질에 대한 계측과 초기 대응이 중요하다. 본 논문에서는 실시간으로 전력 품질을 계측하고 고조파를 분석하여 모니터링 할 수 있는 시스템 제안한다. 마이크로칩의 dsPIC33FJ256GP710A칩을 이용한 DM240001보드를 이용하여 최대 3상 3선에 해당하는 배선 방식의 전력 품질을 계측하는 시스템을 설계하였고, 계측 알고리즘의 최적화로 전력 품질의 순간적인 변화를 측정할 수 있도록 하였다. 또한, 최대 31차에 해당하는 고조파들에 대하여 전압과 전류의 왜율과 수요 전류 왜율에 대해서도 측정 가능하도록 설계하였다.

공장 전기 설치를 위한 휴대용 전력품질 모니터링 시스템 (Hand-Held Power Quality Monitoring System for Factory Electrical Installation)

  • 최상열
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.113-118
    • /
    • 2015
  • 본 연구에서는 휴대용 계측기기를 이용한 공장 수용가 전력품질 분석시스템을 제시한다. 기존의 전력품질 분석시스템은 주로 대규모 공장 수용가에서 상시 연결 되어, 공장 전력 데이터를 연속적으로 취득, 저장한 후 분석까지 수행하고 있다. 그러나 이러한 시스템의 문제점은 데이터 취득을 위해 설치된 미터에서 수집된 Raw 데이터를 이용하여 공장 수용가의 전체적인 전력 품질을 감시 할 수는 있으나, 비선형 부하의 조합으로 인한 전력품질 저하 발생 시에는 그러한 상황에 대한 구체적인 원인을 파악하는 것은 불가능하다. 따라서 본 연구에서는 공장의 전력품질 저하가 발생되는 경우 의심되는 여러 부하의 전압, 전류를 직접 측정하여 그 원인이 되는 지점을 쉽게 찾아내고 그에 상응하는 조치가 가능하도록, 휴대용 계측기기 기반 공장 수용가 전력품질 분석시스템을 제시함으로써 보다 안정적인 공장 전력 부하 운영이 가능하도록 한다.

교류철도급전계통에 전력품질보상장치 적용에 관한 연구 (A Study on the Application of UPQC in AC Railway System)

  • 최준호
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.220-229
    • /
    • 2004
  • 전기 철도계통은 기존 전력계통과 달리 단상, 대용량 부하로 필연적으로 전압강하, 전압불평형 및 고조파 왜곡 등의 전력품질의 문제가 발생한다. 최근 철도계통의 전력품질문제는 철도차량 및 시스템의 제어 및 안전 때문에 중요한 화두가 되고 있다. 이는 또한 기존 전력계통의 전력품질에도 영향을 미친다 본 논문에서는 전기철도 급전시스템에 발생하는 전력품질문제의 보상에 관한 연구를 수행하고자 한다. 이를 위해 국내 교류전기철도 표준 급전방식인 AT(Auto Transformer)급전시스템, 철도급전변압기인 스콧트 변압기(Scott Transformer), AT변압기, 철도선로 및 철도 차량부하를 모델링 하였다. 과도응답은 전자기과도해석 프로그램인 PSCAD/EMTDC를 사용하여 해석 하였다. 또한 전력품질을 보상하기위한 방안으로 급전선-전차선에 설치되는 전력품질보상기(Unified Power Quality Conditioner : UPQC)를 제안하였고 이의 성능 및 유효성을 시뮬레이션을 통하여 확인하였다.