• Title/Summary/Keyword: Power quality

Search Result 5,263, Processing Time 0.043 seconds

Power Quality Measurement and Analysis of Extra-High Voltage Customer (특고압 수용가의 전력품질 측정 및 분석)

  • Cho, Jae-Hyeong;Lee, Jong-Pil;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.286-290
    • /
    • 2015
  • Power system is composed of a number of power devices and equipment. This factor affects the power quality is also displayed very complicated and varied. The accurate measurement and analysis of the causes of power quality problems is difficult. In preparing for these issues, there are many difficulties. In this study, Power quality of A public establishment of Chungbuk province were measured and analyzed. Measurement results of the fifth harmonic current was very large. Accordingly, the harmonic reduction will be needed. This research will be utilized as fundamental data to improve power quality for power utility and customer.

A web-based power quality monitoring system in the Substation Automation System (변전소 자동화 환경에서 웹 기반 전기품질 감시 시스템)

  • Park D. H.;Lim S. J.;Shin J. H.;Lim S. I.;Lee S. J.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.378-380
    • /
    • 2004
  • Along with the increase of the importance of power quality, many various systems are dedicated in the analysis of power quality nowadays. But there still exists the same problems for realizing such kind of analysis systems well. One is the customization of the power quality measure devices; The other is an economic problem. This paper presents the usefulness and the advantage of the ICD (Intelligent Electronic Device) as the measure device of power quality And this paper detailedly describes the development procedure of web-based power quality monitoring system through ActiveX controls. Now this power quality monitoring system is already applied to the substation automation system.

  • PDF

IEC61850 Process Bus Based Distributed Power Quality Monitoring (IEC61850 프로세서 버스 기반 분산형 전력품질감시)

  • Park, Jong-Chan;Kim, Byung-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.13-18
    • /
    • 2007
  • In this paper, authors deal with an application of power quality monitoring using the Sampled Value which is described in the IEC61850 International Standard for substation communication. Firstly, while Merging Unit is designed as a process level device transmitting sensor data, the practical problems such as time delay compensation and optical fiber communication are issued. Secondly, the Sampled Value message which is proper to a power quality monitoring system is presented. Because the power quality monitoring system requests non time critical service comparing to protection and control applications, the Sampled Value service message structure is introduced to improve efficiency. At last, the power quality monitoring server having various power quality analysis functions is suggested to verify the performance of Merging Unit. With the diverse experiments, it is proved that the process bus distributed solution is flexible and economic for the power quality monitoring.

A Model for Power Quality Control Mechanism for Electric Power Market (전력시장체제하에서의 전력품질제어 매커니즘에 대한 모델링)

  • Lee, Geun-Joon;Yun, Suk-Ho;Heydt, G.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.15-19
    • /
    • 2002
  • To provide a specified power quality under electric market system is becoming an important issue for customers and utility company. However, there is no realistic infra-structure to design a power system for the specified power quality. Present electric market is operating under the economic point of view. The low price could be attractive. but the effect of low price and low power quality for the long time should be considered for the system safety. This paper presents a model which conceptualize the dynamic power quality control mechanism to minimize total cost of a society which is affected electric power quality. This model aims to produce a basic infra-structure to balance cost and quality under the electric market system.

  • PDF

The Design of Control Algorithm for Unified Power Quality Compensator (3상 직병렬보상형 전력품질 보상장치(UPQC)의 제어 알고리즘 설계)

  • Jeon Jin Hong;Kim Tae Jin;Ryoo Hong Je;Kim Hwang Su
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.351-353
    • /
    • 2004
  • In recent years, customers and power supplies are interested in power quality. Demands of customers are change from standard quality of distribution power system to various high quality of distribution power system. so, it is necessary to apply power quality compensator. in our project, we develop the UPQC(Unfied Power Quality Compensator of 45kVA which compensates power factor and voltage sag, interruption. it is very frequently occurred power quality $problems^{[1-3]}$ As a series and shunt compensator, UPQC consists of two inverters with common do link capacitor bank. It compensates the current quality in the shunt part and the voltage quality in the series part. In this paper, we present the design and control algorithm for 4SkVA UPQC system. As a control algorithm is implemented by digital controller, we consider sample-and-hold of signals. In this simulation, we use EMTDC/PSCAD V3.0 software which can simulate instantaneous voltage and current.

  • PDF

Digital-Controlled Single-Phase Unified Power Quality Conditioner for Non-linear and Voltage Sensitive Loads

  • Ryoo Hong-Je;Kim Jong-Soo;Kisck Dragos Ovidiu
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.374-381
    • /
    • 2005
  • The ability to provide quality power has become a significant issue in power systems. The main causes of poor power quality are harmonic currents, poor power factor, supply-voltage variations, etc. A technique of achieving both active current distortion compensation, power factor correction and also mitigating the supply-voltage variation (sag or swell) at the load side is presented in this paper. The operation and rating issues of the proposed Single-phase Unified Power Quality Conditioner are also highlighted. To reduce the total cost while simultaneously increasing the performance, the system is fully digitally controlled using the fixed-point TMS320F240 digital signal processor. The performances of the UPQC, which is composed by shunt and series PWM controlled-converters, have been verified on a laboratory prototype.

Performance Analysis of UPQC(Unified Power Quality Conditioner) with Compensation Capability for Voltage Interruption (순간정전에 대한 보상능력을 갖는 UPQC(Unified Power Quality Conditioner)의 성능해석)

  • 김희중;배병열;한병문;설승기;조보형
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.5
    • /
    • pp.279-286
    • /
    • 2003
  • A new UPQC(unified power quality conditioner), which consists of series inverter, shunt inverter, dc/dc converter, and energy storage, is proposed. The proposing UPQC can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance, and voltage interruption. The control strategy for the proposing UPWQC was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the EMTDC/PSCAD simulation and the experimental work with the hardware prototype. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems or industrial power systems and can be utilized for the custom power device in the future distribution system.

Performance Analysis for the UPQC(Unified Power Quality Conditioner) Interconnected to the Distributed Generation System (분산전원 연계형 UPQC(Unified Power Quality Conditioner)의 성능해석)

  • 김희중;배병열;한병문
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.152-160
    • /
    • 2004
  • A novel UPQC(Unified Power Quality Conditioner), which consists of series inverter, shunt inverter, distributed generation system, is proposed. The proposing system can compensate reactive power, harmonics, voltage sag and swell, voltage interruption etc. through the change of paralleling operation mode and islanding operation mode. The control strategy for the proposing system was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the PSCAD/EMTDC simulation and the experimental work with the hardware prototype. The proposing system has the ultimate capability of improving power quality at the point of installation on power distribution systems or Industrial power systems and can be utilized for the custom power device in th future distribution system.

The Study of Distributed Disturbance Recording System (분산형 사고파형저장 시스템에 대한 연구)

  • Park, Jong-Chan;Lee, Se-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.30-35
    • /
    • 2008
  • In this paper, the application of power Quality monitoring based on Sampled Value(SV) which is introduced in the IEC61850 International Standard for substation communication are discussed. Firstly, while Merging Unit(MU) is designed as a process level device transmitting sensor data, the practical problems such as time delay compensation and optical fiber communication are encountered. Secondly, the Sampled Value message which is proper to a power quality monitoring system is presented. Because the power quality monitoring system requests less time-critical service compared to protection and control applications, the Sampled Value service message structure is introduced to improve efficiency. Lastly, the power quality monitoring server having various power quality analysis functions is suggested to verify the performance of Merging Unit With the diverse experiments, it is proved that the process bus distributed solution is flexible and economic for the power quality monitoring.

Power Flow Control of a Multi-bus/Three-feeder Distribution System Using Generalized Unified Power Quality Conditioner

  • Mohammed, B.S.;Ibrahim, R.;Perumal, N.;Rao, K.S. Rama
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.8-17
    • /
    • 2015
  • This paper analyses the power flow of a three-feeder/multi-bus distribution system by a custom Generalized Power Quality Conditioner (GUPQC). The GUPQC has been realized by three voltage source converters (VSCs) coupled back-to-back through a common DC-link capacitor on the DC-side. One feeder was controlled by the shunt compensator, whereas each of the other two feeders was controlled by the proposed novel series compensator. The GUPQC has the capability to simultaneously compensate voltage and current quality problems of a multi-bus/three-feeder distribution system. Besides that, the power can be transferred from one feeder to other feeders to compensate for poor power quality problems. Extensive simulation studies were carried out by using MATLAB/SIMULINK software to establish the ability of the GUPQC to improve power quality of the distribution systems under distorted supply voltage conditions.