• Title/Summary/Keyword: Power system outage

Search Result 332, Processing Time 0.035 seconds

Economic Analysis of Jeju Island Power System Outage Using Event Study (이벤트 스터디 기법을 이용한 제주 정전의 경제적 파급효과 분석)

  • Kim, Jin-A;Lee, Jae-Hee;Lee, Jong-Uk;Joo, Sung-Kwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.46-50
    • /
    • 2010
  • Power system outages can lead to huge economic losses for various industries. Jeju island power system outage in 2006 also caused significant social and economic impacts in Korea. There have been numerous attempts to evaluate the economic costs of power system outages. Power system outages can also have financial impacts on electric power industry. This paper attempts to analyze the economic impacts of the 2006 Jeju island power system outage on the values of the firms in the power industry using event study. Empirical analysis results are presented to show the economic impacts of the 2006 Jeju island outage on the values of the firms in the power industry.

A Study on the DB Management System for Outage Management of Power System (전력계통설비 정지관리를 위한 DB관리 구축방안에 관한 연구)

  • Kim T. W.;Heo J. Y.;Kim C. W.;Lee S. W.;Kim J. C.;Lee G. Y.;Lee S. J.;Lee C. G.;Cho B. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.110-112
    • /
    • 2004
  • The outage management is very important because the outage causes a severe damage to the power system. Therefore, the utilities employ the outage management system, which is different from each others. This paper suggests the four kind of database systems for outage management. The efficiency of the outage management may be improved by using the suggested database system.

  • PDF

The Reliability Evaluation and Outage Cost Assessment of Composite Power System (복합전력계통의 유효부하지속곡선을 이용한 신뢰도 평가 및 공급지장비 추정)

  • Moon, Seung-Pil;Kim, Hong-Sik;Jang, Soon-Ryong;Choi, Jae-Seok;Kang, Jin-Jung;Cho, Jong-Man
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1033-1035
    • /
    • 1998
  • This paper presents a new analytical method for assessing outage cost of composite power system with considering transmission system uncertainty. Composite power system ELDC(CMELDC) was developed and proposed from reliability evaluation of composite power system in order to analysis the outage cost on HLII. In this study, considering the characteristic of each load point, the CMELDC was used for outage cost assessment and reliability evaluation at each load point. The characteristics and effectiveness of this methodology are illustrated by the case study (IEEE-RTS 24Buses).

  • PDF

A Study on the Outage Management Standards for Power System (전력계통설비의 정지관리 체계화 방안에 대한 연구)

  • Heo J. Y.;Kim C. H.;Kim J. C.;Lee G. Y.;Lee S. J.;Lee C. G.;Cho B. S.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.107-109
    • /
    • 2004
  • It is very important to operate a power system safely. An fault may causes the cascading outages in power system. Use of systematic, precise definitions related to the outages is essential for meaningful exchange of data. Moreover, it is necessary that specific instructions for reporting outages is developed. This paper presents the outage management for a power system. The outage managements of the many utilities are researched, which include the definition, classification, index and report of outage. Finally, the outage management standard is proposed, and the necessity and structure of KERC(Korean Electric Reliability Council) are presented

  • PDF

A Development Of An Outage Scheduling Program (휴전일정검토 프로그램 개발)

  • Lee, Woon-Hee;Zoo, Haeng-Roe
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.30-32
    • /
    • 2006
  • New building, reinforcement, maintenance and test of power equipments are always necessary in a power system. Our power system is getting old and the total power capacity is also getting large, so power equipment outages are getting often. Power euipment outages make less margine for a stable condition of a power system operation. Therefore, through overviews and countermeasures against the outage should be made in order to be in a stable operational conditions during the outage. We have too many outages over 300 per month in our power system. So, we can't have enough time to study our power system and to make countermeasures without a helping program. This program is designed to give various and appropriate informations necessary for an outage scheduling. By applying this program, we can raise the job efficiency high and spare the time spent. So we can afford to do through system studies and make good countermeasures. I think this program can contribute greately to power system stable operation.

  • PDF

Outage Analysis and Optimization for Four-Phase Two-Way Transmission with Energy Harvesting Relay

  • Du, Guanyao;Xiong, Ke;Zhang, Yu;Qiu, Zhengding
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.10
    • /
    • pp.3321-3341
    • /
    • 2014
  • This paper investigates the outage performance and optimization for the four-phase two-way transmission network with an energy harvesting (EH) relay. To enable the simultaneous information processing and energy harvesting at the relay, we firstly propose a power splitting-based two-way relaying protocol (PSTWR). Then, we discuss its outage performance theoretically and derive an explicit expression for the system outage probability. In order to find the optimal system configuration parameters such as the optimal power splitting ratio and the optimal transmit power redistribution factor, we formulate an outage-minimized optimization problem. As the problem is difficult to solve, we design a genetic algorithm (GA) based algorithm for it. Besides, we also investigate the effects of the power splitting ratio, the power redistribution factor at the relay, and the source to relay distance on the system outage performance. Finally, extensive simulation results are provided to demonstrate the accuracy of the analytical results and the effectiveness of the GA-based algorithm. Moreover, it is also shown that, the relay position greatly affects the system performance, where relatively worse outage performance is achieved when the EH relay is placed in the middle of the two sources.

A Restoration Algorithm using Moving the tie Switch in Distribution System in case of Fault Occur in Power system Substation MTR (변전소 내 주변압기 사고 발생 시 배전계통 연계점 이동을 통한 복구 알고리즘)

  • Hong, Jun-Ho;Lee, Seung-Jae;Choi, Myeon-Song;Lim, Il-Hyung;Kim, Tae-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.159_160
    • /
    • 2009
  • In this paper proposes a new algorithm of efficiency outage restoration using a outage load switching to a healthy MTR a fault occurrence at a MTR. In addtion, proposed algorithm includes a outage restoration method which keeps MTR optimal capacity with reorganization of distribution network in case it can not restore outage state loads caused by shortage of healthy MTR remain capacity. In case that proposed sequence still can not complete restoration, this paper suggests a efficiency outage restoration with objective function included priority in outage loads.

  • PDF

Outage Detection and Recovery using Neighbor Base Station in Mobile Communication System (이동통신 시스템에서 이웃 기지국을 이용한 Outage 검출 및 복구 기법)

  • Kim, Jaejeong;Ji, Seunghwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.661-663
    • /
    • 2021
  • Network performance is degraded when the UE is disconnected because the outage occurs at the base station in a mobile communication system. Therefore it is important to detect and recover the outage. In this paper, detecting the outage base station by using the KPI and the network scanning in the neighbor base station, and increasing the transmit power and changing the frequency band to recovery the outage scheme is proposed. The proposed scheme uses not only the KPI of the base station but also the network scanning of the neighbor base stations to detect the outage base station, so that it is possible to detect the outage base station more accurately. In addition, when the outage occurred, the neighbor base station changes the transmit power and frequency band to recover the outage with less signal interference.

  • PDF

Web based Online Outage Cost Assessment and Information System of Electrical Energy (웹기반 온라인 전기에너지 공급지장비 추정 및 정보 시스템의 개발)

  • Lim, Jin-Taek;Choi, Jae-Seok;Jeon, Dong-Hoon;Seo, Chul-Soo;Lee, Jae-Gul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1249-1259
    • /
    • 2012
  • This paper proposes a Web Based Online Outage Cost Assessment and Information System(WOOCAIS) for power system outage cost assessment. The proposed WOOCAIS is a kind of web based survey method for outage cost assessment. While conventional survey methods have done outage cost assessment based on survey paper lists collected by post mail or visiting customers, the proposed WOOCAIS is a web based online survey operation and assessment system. Therefore, it can curtail expenditure for survey and also is more convenient than conventional method. It will be set up for actual outage cost assessment system of KEPCO in South Korea in the near future. The WOOCAIS will be applied in various research and actual planning and operation areas. First of all, the assessed results may be not only applied as one of objective function for generation system and grid expansion but also operational planning problems in power system.

Development of a Numerical Analysis Method for the Outage Cost Assessment at Load Points (부하지점별 공급지장비추정을 위한 수치해석적 방법의 개발)

  • Choi, Jae-Seok;Kim, Hong-Sik;Moon, Seung-Pil;Kang, Jin-Jong;Kim, Ho-Yong;Park, Dong-Wook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.11
    • /
    • pp.549-557
    • /
    • 2000
  • This study proposes a new numerical analysis method for assessing the outage cost of the composite power system with considering transmission system at load points. The proposed method comes from combination of the expected energy not served curve(EENSC) with the marginal outage cost function obtained at load points. Uncertainty of the outages of the generation and transmission systems was also included in this study. This study can be categorized into three processing parts as like as follows. Firstly, EENSC at load points was developed newly from the composite power system effective load duration curve which has been proposed by the authors. Secondly, this study proposes a new technical method for determining the coefficients of the marginal outage cost functions at load points in the composite power system(Generation and Transmission systems). It is a main key point that the mathematical expression for the marginal outage cost function at a load point is formulated and evaluated using relations between the GNP (or GDP) and the electrical energy demand at the load pint. Finally, the outage cost was calculated in this paper by combining the proposed EENSC with the marginal outage cost function evaluated at each load point. It is another important feature that the average costs for future at load points can be forescasted using the proposed approach. The effectiveness of the proposed new approach is demonstrated by the case studies with the IEEE-RTS.

  • PDF