• Title/Summary/Keyword: Pulse Injection Method

Search Result 73, Processing Time 0.022 seconds

Study of Pulse Generation Technique for Serial dual Electrode Detection of Amino Acids and Proteins in Flow Injection Analysis

  • Fung, Ying-Sing;Mo, Song-Ying
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.575-582
    • /
    • 1995
  • A new analytical procedure using a serial dual electrode detector was developed for the analysis of amino acids and proteins. Bromine was generated at the upstream electrode and detected by the downstream electrode. The presence of amino acids and proteins was shown to lower the downstream current but with no apparent effect on the upstream current. This indirect mode of detection can be applied to the determination of amino acids and proteins which are electrochemically inactive or too large to be accessible to the electrode surface for electron exchange. The method is shown capable to determine various amino acids (cystine, tyrosine, lysine, tryptophan, glycine, methionine and arginine) and proteins (cytochrome c, hemoglobin, HAS, a-Amylase, Conalbumin I, Catalase and Myglobin) with linear working range for amino acids between $10^{-6}$ to $10^{-3}M$ and total proteins between $10^{-7}$ to $10^{-3}M$. The method has been applied for the analysis of amino acids and total protein in food using Flow Injection Analysis with results obtained comparable to those using the traditional analytical procedure. Use of pulse generation technique was shown to produce a more stable flow injection analysis peaks for repetitive determination than the use of conventional constant current method which showed increase of the background current after determination over 200 minutes. The pulse method was found to give stable baseline even after 400 minutes. Thus, the method is shown able to provide a suitable analytical procedure for automatic analysis of amino acids and proteins in food by flow injection analysis.

  • PDF

Deposition mechanism of $Bi_4Ti_3O_{12}$ films on Si by MOCVD and property improvement by pulse injection method (MOCVD $Bi_4Ti_3O_{12}$ 박막의 실리콘 위에서의 증착기구 및 유기 금속원료의 펄스주입법에 의한 박막 특성 개선)

  • 이석규;김준형;최두현;황민욱;엄명윤;김윤해;김진용;김형준
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.373-378
    • /
    • 2000
  • There was a great difference in the formation kinetics of $TiO_2$ and $Bi_2O_3$ on silicon, but the growth of bismuth titanate (BIT) thin film was mainly limited by the formation of $TiO_2$. As a result, the BIT film was easy to be lack of bismuth. The pulse injection metalorganic chemical vapor deposition (MOCVD) process was introduced in order to overcome this problem by recovering the insufficient bismuth content in the film. By this pulse injection method, bismuth content was increased and also the uniform in-depth composition of the film was attained with a abrupt $Bi_4Ti_3O_{12}/Si$ interface. In addition, the crystallinity of $Bi_4Ti_3O_{12}$ thin film prepared by pulse injection process was greatly improved and the leakage current density was lowered by 1/2~1/3 of magnitude. Clockwise hysteresis of C-V was observed and the ferroelectric switching was confirmed for $Bi_4Ti_3O_{12}$ film deposited by pulse injection method.

  • PDF

Effect of Mountain Cultivated Ginseng Pharmacopuncture on Heart Rate Variability(HRV), Pulse Wave Velocity(PWV) in Middle Aged Women (산양삼약침이 정상 중년여성의 심박변이도(HRV), 맥파속도(PWV)에 미치는 영향)

  • Park, Sang-Wook;Kim, Yi-Soon;Hwang, Won-Deok;Kim, Gyeong-Cheol
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.97-105
    • /
    • 2011
  • Objectives : The aim of this experiment is to know the effect of mountain cultivated ginseng pharmacopuncture on heart rate variability(HRV), pulse wave velocity(PWV) in middle aged women. Methods : We investigated on 20 healthy Middle Aged women volunteers. First, we measured their heart rate variability(HRV), pulse wave velocity(PWV) and then mountain cultivated ginseng pharmacopuncture 20cc were injected on them. After 30 minutes, we measured heart rate variability(HRV), pulse wave velocity(PWV) again. As a result, method of one-group pretest-posttes design were used for evaluation. Results : 1. In HRV, MeanHRV is significantly decreased from 69.15 to 63.34 after injection. 2. MeanRR is significantly increased from 877.20 to 962.10 after injection. SDNN is significantly increased from 32.56 to 41.34 after injection. 3. PNN50 is significantly decreased after injection. RNSSD, SDSD, TP, VLF is significantly increased after injection. 4. Stress resistance ability is significantly increased from 37.55 to 44.60 after injection. 5. In PWV, E-R, E-L, H-R, H-L is significantly decreased after injection. Conclusions : Effect of mountain cultivated ginseng pharmacopuncture on heart rate variability(HRV) increased adaptability of autonomic nervous system and on pulse wave velocity(PWV) decreased arterial stiffness.

Synchronous Carrier-based Pulse Width Modulation Switching Method for Vienna Rectifier

  • Park, Jin-Hyuk;Yang, SongHee;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.604-614
    • /
    • 2018
  • This paper proposes a synchronous switching technique for a Vienna rectifier that uses carrier-based pulse width modulation (CB-PWM). A three-phase Vienna rectifier, similar to a three-level T-type converter with three back-to-back switches, is used as a PWM rectifier. Conventional CB-PWM requires six independent gate signals to operate back-to-back switches. When internal switches are operated synchronously, only three independent gate signals are required, which simplifies the construction of gate driver circuits. However, with this method, total harmonic distortion of the input current is higher than that with conventional CB-PWM switching. A reactive current injection technique is proposed to improve current distortion. The performance of the proposed synchronous switching method and the effectiveness of the reactive current injection technique are verified using simulations and experiments performed with a set of Vienna rectifiers rated at 5 kW.

Effect of Heart Rate Variability, Pulse Wave Velocity in Women of Breast Cancer Patients Care by Mountain Cultivated Ginseng Pharmacopuncture (산양삼(山養蔘) 약침(藥鍼)이 유방암절제술 여성의 심박변이도, 맥파전달속도에 미치는 영향)

  • Kim, Gyeong-Cheol;Park, Sang-Wook;Kim, Yi-Soon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.3
    • /
    • pp.245-260
    • /
    • 2011
  • Objectives: The aim of this experiment is to know the effect of Mountain Cultivated Ginseng Pharmacopuncture on Heart Rate Variability (HRV), Pulse wave velocity (PWV) in Middle Aged Women. Methods: We investigated on 40 women of breast cancer patients. First, we measured their Heart Rate Variability(HRV), Pulse wave velocity (PWV) and then Mountain Cultivated Ginseng Pharmacopuncture $20m{\ell}$ were injected on them. After 30 minutes, we measured Heart Rate Variability(HRV), Pulse wave velocity(PWV) again. As a result, method of non-equivalent control group non-synchronized design were used for evaluation. Results: In HRV, Mean HRV is significantly decreased from 69.15 to 63.34 after injection. Mean RR is significantly increased from 877.20 to 962.10 after injection. SDNN is significantly increased from 32.56 to 41.34 after injection. PNN50 is significantly decreased after injection. RNSSD, SDSD, TP, VLF is significantly increased after injection. Stress Resistance ability is significantly increased from 37.55 to 44.60 after injection. And In PWV, E-R, E-L, H-R, H-L is significantly decreased after injection. Conclusions: Effect of Mountain Cultivated Ginseng Pharmacopuncture on Heart Rate Variability (HRV) increased adaptability of autonomic nervous system and on Pulse wave velocity (PWV) decreased arterial stiffness.

Analysis of the Phase Current Measurement Boundary of Three Shunt Sensing PWM Inverters and an Expansion Method

  • Cho, Byung-Geuk;Ha, Jung-Ik;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.232-242
    • /
    • 2013
  • To obtain phase currents information in AC drives, shunt sensing technology is known to show great performance in cost-effectiveness and therefore it is widely used in low cost applications. However, shunt sensing methods are unable to acquire phase currents in certain operation conditions. This paper deals with the derivation of the boundary conditions for phase current reconstruction in three-shunt sensing inverters and proposes a voltage injection method to expand the measurable areas. As the boundary conditions are deeply dependent on the switching patterns, they are typically analyzed on the voltage vector plane for space vector pulse width modulation (SVPWM) and discontinuous pulse width modulation (DPWM). In the proposed method, the voltage injection and its compensation are conducted within one sampling period. This guarantees fast current reconstruction and the injected voltage is decided so as to minimize the current ripple. In addition to the voltage injection method, a sampling point shifting method is also introduced to improve the boundary conditions. Simulation and experimental results are presented to verify the boundary condition derivation and the effectiveness of the proposed voltage injection method.

An Improvement of PWM Method for Single Phase Current Source Type Active Power Filter (단상 전류원형 능동전력필터를 위한 펄스폭 변조법의 개선)

  • 박인규;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.3
    • /
    • pp.254-262
    • /
    • 1990
  • In the active power filter, the PWM method for controlling the power converter plays an important role for the performance and the efficiency of the filter. In this paper, a new PWM method for the single phase current source type active power filter is presented, which is intended particularly for obtaining the maximum efficiency of the compensation. This method is basically based upon the optimized injection method, but in contrast to the existing method, this method adapts the optimized injection method by putting not only the pulse width, but also the pulse position into control variables. By doing this, when the number of pulses per one cycle is N, lower order harmonics up to the Nth order can be completely eliminated by the filter. So, this method is much more efficient than any other existing method. These characteristics are well verified by the computer simulations and the experiments.

  • PDF

A New Injection Method of Harmonic Compensation Current by Active AC Power Filter (능동형 교류 전력 필터에 의한 고조파 보상전류의 새로운 주입방식)

  • 박민호;최규하
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.9
    • /
    • pp.361-367
    • /
    • 1985
  • A new injection method is proposed for active power filters to eliminate AC harmonics in ac input current of nonlinear loads such as rectifiers. By injecting the PWM current determined by the proposed injection method, all the harmonics up to order nn can be eliminated to exactly zero. This PWM injection current can be generated by sampling total harmonic wave at the rate of M and the sampled values are converted into the proposed PWM wave with N pulse-width variables and adjustable current magnitude Im. These variables are deetermined by solving a set of N nonlinear harmonic equations and the harmonic-elimination characteristics of the new injection are investigated through digital computer sinmulation. Also by comparing between the simulated results and the ones synthesized by data stored in EPROM, the possibility of the suggested injection method can be shown.

  • PDF

Sensorless Control of IPMSM with a Simplified High-Frequency Square Wave Injection Method

  • Alaei, Ahmadreza;Lee, Dong-Hee;Ahn, Jin-Woo;Saghaeian Nejad, Sayed Morteza
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1515-1527
    • /
    • 2018
  • This paper presents a sensorless speed control of IPMSM (Interior Permanent Magnet Synchronous Motor) using the high-frequency (HF) square wave injection method. In the proposed HF pulsating square wave injection method, injection voltage is applied into the estimated d-axis of rotor and high-frequency induced q-axis current is considered to estimate the rotor position. Conventional square wave injection methods may need complex demodulation process to find rotor position, while in the proposed method, an easy demodulation process based on the rising-falling edge of the injected voltage and carrier induced q-axis current is implemented, which needs less processing time and improves control bandwidth. Unlike some saliency-based sensorless methods, the proposed method uses maximum torque per ampere (MTPA) strategy, instead of zero d-axis command current strategy, to improve control performance. Furthermore, this paper directly uses resultant d-axis current to detect the magnet polarity and eliminates the need to add an extra pulse injection for magnet polarity detection. As experimental results show, the proposed method can quickly find initial rotor position and MTPA strategy helps to improve the control performance. The effectiveness of the proposed method and all theoretical concepts are verified by mathematical equations, simulation, and experimental tests.

A Study on the Retention Characteristics with the Charge Injection Conditions in the Nonvolatile MNOS Memories (전하주입조건에 따른 비휘발성 MNOS 기억소자의 기억유지특성에 관한 연구)

  • Lee, Kyoung-Leun;Yi, Sang-Bae;Lee, Sang-Eun;Seo, Kwang-Yell
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1265-1267
    • /
    • 1993
  • The switching and the retention characteristics with the injection conditions(pulse height and pulse width) were investigated in the nonvolatile MNOS memories with thin oxide layer of $23{\AA}$ thick. The shift of flatband voltage was measured using the fast ramp C-V method and experimental results were analized using the previously developed models. It was shown that the experimental results were described quit well by the trap-assisted and modified Fowler-Nordheim tunneling models for the voltage pulse of $15V{\sim}19V,\;24V{\sim}25V$, respectively. However, the direct tunneling model was agreement with experimental values in all range of pulse height. As increasing the initial shift of the flatband voltage, the decay rate was increased. But for the same initial shift of the flatband voltage, the decay rate was smaller for low and long pulse than for high and short one.

  • PDF