• 제목/요약/키워드: Pulse Operation

검색결과 778건 처리시간 0.029초

충격기류식 여과집진장치에서 운전조건 변화로 인한 여과저항에 관한 연구[I] (Study on Filter Drag Due to the Change of Operation Conditions in a Pulse Air Jet-type Bag Filter[I])

  • 류재용;서정민;박정호;전보경;최금찬;손영일
    • 한국환경과학회지
    • /
    • 제16권4호
    • /
    • pp.449-458
    • /
    • 2007
  • Research results for the pressure drop variance depending on operation conditions such as change of inlet concentration, pulse interval, and face velocity, etc., in a pulse air jet-type bag filter show that while at $3kg/cm^2$ whose pulse pressure is low, it is good to make an pulse interval longer in order to form the first layer, it may not be applicable to industry because of a rapid increase in pressure. In addition, the change of inlet concentration contributes more to the increase of pressure drop than the pulse interval does. In order to reduce operation costs by minimizing filter drag of a filter bag at pulse pressure $5kg/cm^2$, the dust concentration should be minimized, and when the inlet dust loading is a lower concentration, the pulse interval in the operation should be less than 70 sec, but when inlet dust loading is a higher concentration, the pulse interval should be below 30 sec. In particular, in the case that inlet dust loading is a higher concentration, a high-pressure distribution is observed regardless of pulse pressure. This is because dust is accumulated continuously in the filter bag and makes it thicker as filtration time increases, and thus the pulse interval should be set to below 30 sec. If the equipment is operated at 1m/min of face velocity, while pressure drop is low, the bag filter becomes larger and thus, its economics are very low due to a large initial investment. Therefore, a face velocity of around 1.5 m/min is considered to be the optimal operation condition. At 1.5 m/min considered to be the most economical face velocity, if the pulse interval increases, since the amount of variation in filter drag is large, depending on the amount of inlet dust loading, the operation may be possible at a lower concentration when the pulse interval is 70 sec. However, for a higher concentration, either face velocity or pulse interval should be reduced.

다중회귀모형을 이용한 벤츄리가 없는 충격기류식 여과집진장치 압력손실 예측 (Pressure Drop Predictions Using Multiple Regression Model in Pulse Jet Type Bag Filter Without Venturi)

  • 서정민;박정호;조재환;진경호;정문섭;이병인;홍성철;시바쿠마르;최금찬
    • 한국환경과학회지
    • /
    • 제23권12호
    • /
    • pp.2045-2056
    • /
    • 2014
  • In this study, pressure drop was measured in the pulse jet bag filter without venturi on which 16 numbers of filter bags (Ø$140{\times}850{\ell}$) are installed according to operation condition(filtration velocity, inlet dust concentration, pulse pressure, and pulse interval) using coke dust from steel mill. The obtained 180 pressure drop test data were used to predict pressure drop with multiple regression model so that pressure drop data can be used for effective operation condition and as basic data for economical design. The prediction results showed that when filtration velocity was increased by 1%, pressure drop was increased by 2.2% which indicated that filtration velocity among operation condition was attributed on the pressure drop the most. Pressure was dropped by 1.53% when pulse pressure was increased by 1% which also confirmed that pulse pressure was the major factor affecting on the pressure drop next to filtration velocity. Meanwhile, pressure drops were found increased by 0.3% and 0.37%, respectively when inlet dust concentration and pulse interval were increased by 1% implying that the effects of inlet dust concentration and pulse interval were less as compared with those changes of filtration velocity and pulse pressure. Therefore, the larger effect on the pressure drop the pulse jet bag filter was found in the order of filtration velocity($V_f$), pulse pressure($P_p$), inlet dust concentration($C_i$), pulse interval($P_i$). Also, the prediction result of filtration velocity, inlet dust concentration, pulse pressure, and pulse interval which showed the largest effect on the pressure drop indicated that stable operation can be executed with filtration velocity less than 1.5 m/min and inlet dust concentration less than $4g/m^3$. However, it was regarded that pulse pressure and pulse interval need to be adjusted when inlet dust concentration is higher than $4g/m^3$. When filtration velocity and pulse pressure were examined, operation was possible regardless of changes in pulse pressure if filtration velocity was at 1.5 m/min. If filtration velocity was increased to 2 m/min. operation would be possible only when pulse pressure was set at higher than $5.8kgf/cm^2$. Also, the prediction result of pressure drop with filtration velocity and pulse interval showed that operation with pulse interval less than 50 sec. should be carried out under filtration velocity at 1.5 m/min. While, pulse interval should be set at lower than 11 sec. if filtration velocity was set at 2 m/min. Under the conditions of filtration velocity lower than 1 m/min and high pulse pressure higher than $7kgf/cm^2$, though pressure drop would be less, in this case, economic feasibility would be low due to increased in installation and operation cost since scale of dust collection equipment becomes larger and life of filtration bag becomes shortened due to high pulse pressure.

펄스 모드로 작동하는 증기냉각 전류 도입선에 관한 연구 (Investigation on vapor-cooled current leads operating in pulse mode)

  • 인세환;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.66-72
    • /
    • 2002
  • This paper describes numerical modeling for thermal characteristic of vapor-cooled current leads under pulse operation. The transient thermal analysis considers the temperature difference between a helium gas (low and a copper lead and temperature dependent properties of helium gas, copper and stainless steel. This numerical modeling was compensated and validated by an experiment with commercially available 100 A vapor-cooled current leads. A proper overloading factor was suggested for the current leads under pulse operation through this modeling, which can significantly reduce heat input to a cryostat.

Double Pulse Memory 방식을 이용한 DC Plasma Display Panel의 특성 연구 (Characteristics of DC Plasma Display Panel with Double Pulse Memory)

  • 최경철;신범재;왕기웅
    • 전자공학회논문지B
    • /
    • 제29B권1호
    • /
    • pp.67-75
    • /
    • 1992
  • A new method of driving the PDP(Plasma Display Panel) was proposed and its characteristics were investigated. Applying high frequency non-discharge pulses to an auxiliary anode resulted an increased region of stable operation, decreased delay time and increased light intensity. It is suggested that PDP with DPM (Double Pulse Memory) drive technique improves the delay time, luminance, region of stable operation and luminous efficacy compared to PDP with PPM(Planar Pulse Memory) drive technique developed by NHK Lab. in Japan.

  • PDF

Characterization of behaviors using electric pulse for phase switching operation of Ge2Sb2Te5 material

  • 이현철;최두진
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.322-322
    • /
    • 2016
  • Phase change memory (PCM) has attracted much attention as one of the most promising candidates for next-generation nonvolatile memory. In that regard, the purposes of the study are to propose reference of effective pulse parameter to control phase switching operation and to invest the effect of nitrogen doped in PCM materials for improved cycling stability and economic energy consumption. Switching operation of PCM is affected by electric pulse parameter and as shown in figure.1 are composed to RT(rising time), ST(setting time), FT(falling time) and the effect of these parameter was precisely investigated. Transmission electron microscope (TEM) was used to confirm fine structure and retention cycle test was conducted to confirm reliability. Finally improvement reliability and economic power consumption in quantitatively are obtainable by optimum pulse parameter and nitrogen doping in GST material. these study is related to the engineering background of other semiconductor industries and it have confirmed to possibility further applications.

  • PDF

벌채작업(伐採作業)에서의 작업강도(作業强度) 측정연구(測定硏究) -침엽수(針葉樹) 간벌림에(間伐林)서- (Studies on Working Intensity in Felling Operation of the Thinning Forest -In Thinning of Some Conifer Species-)

  • 박수규;강건우
    • 한국산림과학회지
    • /
    • 제85권3호
    • /
    • pp.396-408
    • /
    • 1996
  • 본 연구는 우리나라 간벌림 벌채작업에서 작업강도를 구명하여 산림작업을 성력화하며, 아울러 작업방법의 개선과 생산성 향상을 도모하는데 그 목적이 있다. 이를 구명하기 위하여 침엽수 간벌림에서 벌채작업을 요소작업으로 구분하여 순수작업시간과 맥박수를 측정 분석하였으며, 그 결과는 다음과 같다. 1. 맥박수 측정 분석에서 전체 순수작업시간에서의 1분당 평균맥박수는 작업원 A의 경우 108로 나타났으며, 작업원 B의 경우 130, 작업원 C는 119, 그리고 작업원 D는 125로 나타났다. 2. 요소작업 구분별로 맥박수를 분석한 결과에서는 1분당 맥박수가 가장 높을 때는 작업원 A의 경우 주위정리에서 115였고, 작업원 B는 이동에서 131, 작업원 C는 지타작업에서 122, 작업원 D는 현목처리에서 128로 나타났다. 3. 작업원별로 기준맥박을 100%로 보았을 때 작업강도는 작업원 A(기본맥박 61=100%)가 전체 작업강도 160%, 요소작업 구분중에서는 주위정리가 188%로 가장 높게 나타났다. 작업원 B(기본맥박 57=100%)의 전체 작업강도는 220%, 요소작업중에서는 이동이 229%로 가장 높았으며, 작업원 C(기본맥박 73=100%)의 경우에는 전체 강도는 159%, 요소작업중에서는 지타작업이 168%로 가장 높았고, 작업원 D(기본맥박 70=100%)는 전체 작업강도 156%, 요소작업중에서는 현목처리가 182%로 가장 높게 나타났다. 4. 전체 작업강도를 나다내는 작업원에 따른 노동이행능력 한계점에서의 1분당 초과맥박수는 작업원 A의 경우 30, 작업원 B의 경우 207, 작업원 C는 14이며, 작업원 D는 67로 작업원 B가 가장 작업강도가 높아 신체적인 부담을 크게 받는 것으로 나타났다.

  • PDF

Unknown Inputs Observer Design Via Block Pulse Functions

  • Ahn, Pius
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권3호
    • /
    • pp.205-211
    • /
    • 2002
  • Unknown inputs observer(UIO) which is achieved by the coordinate transformation method has the differential of system outputs in the observer and the equation for unknown inputs estimation. Generally, the differential of system outputs in the observer can be eliminated by defining a new variable. But it brings about the partition of the observer into two subsystems and need of an additional differential of system outputs still remained to estimate the unknown inputs. Therefore, the block pulse function expansions and its differential operation which is a newly derived in this paper are presented to alleviate such problems from an algebraic form.

3전극 직류형 PDP의 전기적 특성과 펄스 메모리 구동 (Electrical characteristics and pulse memory operation of 3-electrode DC-PDP)

  • 명대진;손일헌
    • 전자공학회논문지D
    • /
    • 제35D권7호
    • /
    • pp.32-39
    • /
    • 1998
  • This paper presents the experimental results on the 3-electrode DC-PDP which has a common electrode to improve the PDP life cycle. The measured DC characteristic proves the effectiveness of common electrode absorbing about half of discharge currents. The waveforms for pulse memory operation of3-electrode PDP without crosstalk could also be determined from the I-V characteristics. The pulse memory drives of 8*8 cell array show the frequency response fo memory margin and the luminance efficiency of 3-electrode PDP are quite different from genrally known characteristics of 2-electrode DC-PDP.

  • PDF

High Power Density, High Frequency, and High Voltage Pulse Transformer

  • Kim, S.C.;Jeong, S.H.;Nam, S.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권4호
    • /
    • pp.180-184
    • /
    • 2001
  • The high operation frequency mainly reduces transformer volume in the power supply. A high frequency and high voltage pulse transformer is designed, fabricated, and tested. Switching frequency of the transformer is 100 kHz. Input and output voltages of the transformer are 250 V and 4 kV, respectively. Normal operation power of the transformer is 3 kW. Maximum volume of the transformer is 400 $cm^3$. The power density is thus 7.5 W/$cm^3$. The transformer will be installed in a metal box that has nominal operation temperature of 85 degree centigrade. The transformer and other high voltage components in the box will be molded with Silicon RTV(Room Temperature Vulcaniza) that has a very low thermal conductivity. Procedure of design and test results are discussed. Analytical as well as experimental results of varous paramters such as transformer loss, leakage inductance, distributed capacitance are also discussed. In addition, thermal analysis results from ANSYS code for three different operation conditions are discussed.

  • PDF

가포화 자기스위치를 이용한 탈황탈질 시스템의 전원장치에 관한 연구 (A study on topology of the DeNOx, DeSOx using magnetic pulse compressors)

  • 김수홍;이용덕;김승모;김병섭;권병기;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.157-159
    • /
    • 2008
  • Generally, Capacitor charging power supply (CCPS) consist of the full-bridge inverter, LC resonant tank and capacitance load. The multi-connection systems are normally used for high voltage or high power application. In this paper, conventional parallel operation resonant type and proposed series operation PWM type CCPS for pulse corona occurrence of DeSOx, DeNOx system using magnetic pulse compressor make a comparison. The effect of proposed CCPS is verified by circuit characteristics analysis of parallel operation resonant type and series operation PWM type, and it is confirmed by simulation result.

  • PDF