• Title/Summary/Keyword: Pulse Plasma

Search Result 492, Processing Time 0.033 seconds

Anodic Stripping Voltammetric Determinations of Zinc, Cadmium, Lead and Copper in Freshwater and Sediment (담수 및 퇴적물에 함유된 아연, 카드뮴, 납 및 구리의 산화전극 벗김 전압전류법 정량)

  • Hahn, Young Hee;Yoo, Jeong Yeon
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.4
    • /
    • pp.180-185
    • /
    • 1997
  • Zinc, cadmium, lead and copper were simultaneously determined by depositing metals at - 1.200 V vs. a Ag/AgCl(sat. KCl) reference electrode for 150 seconds on a hanging mercury drop electrode(HMDE) or a thin mercury film electrode(TMFE), followed by scanning towards anodic direction using differential pulse voltammetric(DPASV) and square wave voltammetric(SWASV) techniques. The linear calibration curves were obtained for four metal ions simultaneously determined by DPASV with a HMDE in the concentration range between 20 and 100 ppb. However, the linear calibration plots were obtained only for $Cd^{2+}$ and $Pb^{2+}$ in the simultaneous determinations with a TMFE in the concentration range up to 100 ppb using DPASV and up to 10 ppb using SWASV. DPASV with a TMFE was about 15 times more sensitive than DPASV with a HMDE for simultaneous determinations of $Cd^{2+}$ and $Pb^{2+}$. SWASV was about 5 times more sensitive than DPASV at a TMFE. Concentrations of zinc in seven different sediment samples determined by DPASV with a HMDE and inductively coupled plasma-mass spectrometry were compared, resulting with an excellent correlation coefficient of 0.9993 and with no significant difference between two methods after t-test.

  • PDF

The Relationship of Plasma Visfatin Level and Anorexia in Terminal Cancer Patients (말기암환자의 혈중 Visfatin 농도와 식욕부진의 관계)

  • Lee, So Jin;Lee, Joon Yong;Choi, Youn Seon;Lee, June Young
    • Journal of Hospice and Palliative Care
    • /
    • v.17 no.1
    • /
    • pp.18-26
    • /
    • 2014
  • Purpose: Anorexia is a common symptom in terminal cancer patients. Some data have suggested a role of visfatin in regulating feeding behavior. We studied the relationship of a serum visfatin level and anorexia in cancer patients provided with hospice care. Methods: After informed consent was obtained, 69 cancer patients over 20 years old at a hospice center were enrolled in the study from July 2009 to July 2010. We characterized patients by age, sex, body mass index, primary cancer site, and Eastern Cooperative Oncology Group (ECOG) performance status, etc. Also, blood tests were performed to measure the level of hemoglobin, white blood cell (WBC), C-reactive protein (CRP), total cholesterol, albumin, lymphocyte count, glucose, blood urea nitrogen (BUN), creatinine, tumor necrosis factor-alpha (TNF-${\alpha}$), interukin-6, leptin and visfatin. Results: The mean age of subjects was 65.5 years old, According to univariate analysis, pulse, ECOG performance scale, opioid use and visfatin level were different between the anorexia and non-anorexic group (P<0.05). The median visfatin level was higher in the anorexia group than the good appetite group (P=0.0323). Serum visfatin concentrations were not related with either body mass index or serum leptin or total cholesterol levels, but it was negatively correlated with serum albumin levels (P=0.0198) and lymphocyte counts (P=0.0013). Conclusion: This study did not identify a novel link between visfatin levels and anorexia in cancer patients at a hospice.

Electrochemical Determination of Bisphenol A Concentrations using Nanocomposites Featuring Multi-walled Carbon Nanotube, Polyelectrolyte and Tyrosinase (다중벽 탄소 나노 튜브, 전도성고분자 및 티로시나아제 효소로 구성된 나노복합체를 이용한 비스페놀A 맞춤형의 전기화학적 검출법)

  • Ku, Nayeong;Byeon, Ayeong;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.684-689
    • /
    • 2021
  • In this paper, we develop a cost effective and disposable voltammetric sensing platform involving screen-printed carbon electrode (SPCE) modified with the nanocomposites composed of multi-walled carbon nanotubes, polyelectrolyte, and tyrosinase for bisphenol A. This is known as an endocrine disruptor which is also related to chronic diseases such as obesity, diabetes, cardiovascular and female reproductive diseases, precocious puberty, and infertility. A negatively charged oxidized multi-walled carbon nanotubes (MWCNTs) wrapped with a positively charged polyelectrolyte, e.g., polydiallyldimethylammonium, was first wrapped with a negatively charged tyrosinae layer via electrostatic interaction and assembled onto oxygen plasma treated SPCE. The nanocomposite modified SPCE was then immersed into different concentrations of bisphenol A for a given time where the tyrosinase reacted with OH group in the bisphenol A to produce the product, 4,4'-isopropylidenebis(1,2-benzoquinone). Cyclic and differential pulse voltammetries at the potential of -0.08 V vs. Ag/AgCl was employed and peak current changes responsible to the reduction of 4,4'-isopropylidenebis(1,2-benzoquinone) were measured which linearly increased with respect to the bisphenol A concentration. In addition, the SPCE based sensor showed excellent selectivity toward an interferent agent, bisphenol S, which has a very similar structure. Finally, the sensor was applied to the analysis of bisphenol A present in an environmental sample solution prepared in our laboratory.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.

Effect of Pulsatile Versus Nonpulsatile Blood Flow on Renal Tissue Perfusion in Extracorporeal Circulation (체외순환에서 박동 혈류와 비박동 혈류가 신장의 조직관류에 미치는 영향)

  • Kim Hyun Koo;Son Ho Sung;Fang Yang Hu;Park Sung Young;Kim Kwang Taik;Kim Hark Jei;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.1 s.246
    • /
    • pp.13-22
    • /
    • 2005
  • It has been known that pulsatile flow is physiologic and more favorable to tissue perfusion than nonpulsatile flow. The purpose of this study is to directly compare the effect of pulsatile versus nonpulsatile blood flow to renal tissue perfusion in extracorporeal circulation by using a tissue perfusion measurement system. Material and Method: Total cardiopulmonary bypass circuit was constructed to twelve Yorkshire swines, weighing 20$\~ $30 kg. Animals were randomly assigned to group 1 (n=6, non pulsatile centrifugal pump) or group 2 (n=6, pulsatile T-PLS pump). A probe of the tissue perfusion measurement system $(QFlow^{TM}-500)$ was inserted into the renal pa­renchymal tissue. Extracorporeal circulation was maintained for an hour at a pump flow of 2 L/min after aortic cross-clamping. Tissue perfusion flow of the kidney was measured at baseline (before bypass) and every 10 minutes after bypass. Serologic parameters were collected at baseline and 60 minutes after bypass. Result: Baseline parameters were not different between the groups. Renal tissue perfusion flow was substantially higher in the pulsatile group throughout the bypass (ranged 48.5$\~$ 64 in group 1 vs. 65.8$\~$88.3 mL/min/100 g in group 2, p=0.026$\~$ 0.45) The difference was significant at 30 minutes bypass $(47.5{\pm}18.3\;in\;group\;1\;vs.\;83.4{\pm}28.5$ mL/min/100 g in group 2, p=0.026). Serologic parameters including plasma free hemoglobin, blood urea nitrogen, and creatinine showed no differences between the groups at 60 minutes after bypass (p=NS). Conclusion: Pulsatile flow is more beneficial to tissue perfusion of the kidney in short-term extracorporeal circulation. Further study is suggested to observe the effects to other vital organs or long-term significance.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

Rapid Detection of Radioactive Strontium in Water Samples Using Laser-Induced Breakdown Spectroscopy (LIBS) (Laser-Induced Breakdown Spectroscopy (LIBS)를 이용한 방사성 스트론튬 오염물질에 대한 신속한 모니터링 기술)

  • Park, Jin-young;Kim, Hyun-a;Park, Kihong;Kim, Kyoung-woong
    • Economic and Environmental Geology
    • /
    • v.50 no.5
    • /
    • pp.341-352
    • /
    • 2017
  • Along with Cs-137 (half-life: 30.17 years), Sr-90 (half-life: 28.8 years) is one of the most important environmental monitoring radioactive elements. Rapid and easy monitoring method for Sr-90 using Laser-Induced Breakdown Spectroscopy (LIBS) has been studied. Strontium belongs to a bivalent alkaline earth metal such as calcium and has similar electron arrangement and size. Due to these similar chemical properties, it can easily enter into the human body through the food chain via water, soil, and crops when leaked into the environment. In addition, it is immersed into the bone at the case of human influx and causes the toxicity for a long time (biological half-life: about 50 years). It is a very reductive and related with the specific reaction that makes wet analysis difficult. In particular, radioactive strontium should be monitored by nuclear power plants but it is very difficult to be analysed from high-cost problems as well as low accuracy of analysis due to complicated analysis procedures, expensive analysis equipment, and a pretreatment process of using massive chemicals. Therefore, we introduce the Laser-Induced Breakdown Spectroscopy (LIBS) analysis method that analyzes the elements in the sample using the inherent spectrum by generating plasma on the sample using pulse energy, and it can be analyzed in a few seconds without preprocessing. A variety of analytical plates for samples were developed to improve the analytical sensitivity by optimizing the laser, wavelength, and time resolution. This can be effectively applied to real-time monitoring of radioactive wastewater discharged from a nuclear power plant, and furthermore, it can be applied as an emergency monitoring means such as possible future accidents at a nuclear power plants.

The Effect of Aerobic Exercise on Body Composition, Cardiopulmonary Function, Serum Lipid and Antioxidants of Obese College Female Students (에어로빅운동이 비만여대생의 신체조성, 심폐기능, 혈청지질 및 항산화물질에 미치는 영향)

  • Jung Eun-Sook;Park Hyeong-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.1
    • /
    • pp.125-141
    • /
    • 1998
  • The purpose of this research is to analyze the effects of aerobic exercise on body composition, cardiopulmonary function, serum lipid level and antioxidants of obese and normal college female students. The subject group was made up of 13 normal students (below 30% body fat ratio) and 12 obese students (above 30% body fat ratio). After a pretest, the subjects were given an 8-week aerobic program. Then the subjects were given a posttest and analyzed of body composition, serum lipid level, antioxidants and cardiopulmonary function after the 6th and the 8th week of the program. The program schedule was made up of 4 days per week, 60 minutes per day. Test includes B.W., subscapular and triceps subcutaneous fat thickness, change of respiratory gas, and two blood sampling before treadmill exercise and post all out state, which analyzed serum lipid and antioxidants. The subjects performed treadmill exercise starting with 4km/hr of walking and then gradually increase the speed of 1km/hr per minute until all out state. The obtained data were analyzed using SAS program. The statistical methods employed here were one-way ANOVA with repeated measure, Duncan Multiple range test, paired-t test and t-test. The test results and conclusion of this research were as follows. 1. The effects of aerobic exercise on body composition were as follows ; Percent body fat was significantly reduced 6 weeks after the program and lean body mass was significantly increased 8 weeks after the program in both groups(obese group: F=3.44 P=.044, normal group: F=3.30 P=.048). subscapular skinfold of the obese group showed a remarkable decrease after the 6th week(F=4.33 P=.021) triceps skinfold of the normal group showed a remarkable decrease after the 6th and the 8th week(F=4.55 P=.017) compared with readings before the aerobic program, the aerobic program made a bigger difference concerning body fat, lean body mass, subscapular skinfold in the obese group than in the normal group(t=2.41 P=.024, t=2.40 p=.025, t=2.43 p=.028). 2. The effects of aerobic exercise on cardiopulmonary function were as follows ; Maximal $O_2$ uptake/kg was significantly increased 6 weeks after the program in the obese group(F=3.20 P=.054), but not much difference was observed in the normal group. Maximal pulse rate was significantly reduced in both groups after 6 weeks of the program(obese group: F=2.77 P=.087, normal group: F=7.17 P=.001). 3. The effects of aerobic exercise on serum lipid level were as follows ; In a resting period, total cholesterol, Triglyceride, and LDL-cholesterol were slightly higher in the obese group than in the normal group, but HDL-cholesterol was higher in the normal group. But, with the aerobic program, total-cholesterol, Triglyceride, LDL-cholesterol were reduced gradually and HDL-choleterol got increased in both groups, but not much change was noticed in the normal group. However, in the obese group, serum HDL-cholesterol level got increased significantly(F=5.12 P=.012). 4. The effects of aerobic exercise in serum antioxidants were as follows ; In a resting period, the obese group's serum Free Radical and GSSG content were higher than the normal group's and the normal group's serum GSH content was higher than the obese group's. After 6 weeks of the aerobic program, Free Radical was reduced significantly in both groups(obese group: F=13.87 P=.000, normal group: F=18.60 P=.000) In the obese group, 8 weeks after the program, GSH was increased significantly(F=13.78, P=.000). In the normal group, 6 weeks after the program, GSH was reduced but increased again after 8 weeks(F=6.07 P=.005). Plasma GSSG was significantly increased after 8 weeks of exercise in both groups(obese group: F=19.75 P=.000, normal group: F=22.42 P=.000,) Compared with readings before the aerobic program, the aerobic program made a bigger difference serum GSH in the normal group than in the obese group(t=3.37 p=.003). As this result shows, it is known that the regular aerobic exercise improves cardiopulmonary function, body composition, serum lipid effectively and through the serum Free Radical reduction and antioxidant system activation, oxidant stress was suppressed. This effect was higher in the obese group than in the normal one. At least 6weeks exercise period need for improvement of body composition, cardiopulmonary function and activation of antioxidant system. This result suggest that improvement of serum lipid profile was needed longer than 8weeks exercise period.

  • PDF

Voltammetric Sensor Incorporated with Conductive Polymer, Tyrosinase, and Ionic Liquid Electrolyte for Bisphenol F (전도성고분자, 티로시나아제 효소 및 이온성 액체 전해질을 융합한 전압전류법 기반의 비스페놀F 검출 센서)

  • Sung Eun Ji;Sang Hyuk Lee;Hye Jin Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.258-263
    • /
    • 2023
  • In this study, conductive polymers and the enzyme tyrosinase (Tyr) were deposited on the surface of a screen printed carbon electrode (SPCE), which can be fabricated as a disposable sensor chip, and applied to the detection of bisphenol F (BPF), an endocrine disruptor with proven links to male diseases and thyroid disorders, using electrochemical methods. On the surface of the SPCE working electrode, which was negatively charged by oxygen plasma treatment, a positively charged conductive polymer, poly(diallyldimethyl ammonium chloride) (PDDA), a negatively charged polymer compound, poly(sodium 4-styrenesulfonate) (PSS), and another layer of PDDA were layered by electrostatic attraction in the order of PDDA, PSS, and finally PDDA. Then, a layer of Tyr, which was negatively charged due to pH adjustment to 7.0, was added to create a PDDA-PSS-PDDA-Tyr sensor for BPF. When the electrode sensor is exposed to a BPF solution, which is the substrate and target analyte, 4,4'-methylenebis(cyclohexa-3,5-diene-1,2-dione) is generated by an oxidation reaction with the Tyr enzyme on the electrode surface. The reduction process of the product at 0.1 V (vs. Ag/AgCl) generating 4,4'-methylenebis(benzene-1,2-diol) was measured using cyclic and differential pulse voltammetries, resulting in a change in the peak current with respect to the concentration of BPF. In addition, we compared the detection performance of BPF using an ionic liquid electrolyte as an alternative to phosphate-buffered saline, which has been used in many previous sensing studies. Furthermore, the selectivity of bisphenol S, which acts as an interfering substance with a similar structure to BPF, was investigated. Finally, we demonstrated the practical applicability of the sensor by applying it to analyze the concentration of BPF in real samples prepared in the laboratory.