• Title/Summary/Keyword: Pumping-up below

Search Result 7, Processing Time 0.02 seconds

Experimental Study on the Infilling Characteristics of CFT Column Infilled by Pumping-Up Below (하부압입공법에 의한 콘크리트 충전강관(CFT)기둥의 충전특성에 관한 실험적 연구)

  • Kim, Myoung Mo;Jeon, Sang Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.2
    • /
    • pp.375-383
    • /
    • 2002
  • To evaluate the applicability of the construction method involving infilling CFT columns by pumping-up, a trial construction was done using 6 actual size test samples. The 12.8m-high test samples were similar to a four-story building scale. The pumping-up level was controlled at 12m. The test used two types of high performance concrete with $450kgf/cm^2$ standard design strength, and a concrete pump which is used domestically. The pressure changes in pipes or pump as well as the changes in concrete characteristics were measured during construction. in order to evaluate applicability. After the concrete hardened, the column was dismantled. The filled state of the concrete, concrete strength distribution according to column height, etc., were checked to evaluate the quality of the concrete, From the results, some basic data which characterize the pumping-up pressure were suggested. Also, the strength of hardened concrete as well as the filled state were proven to be acceptable ranges.

Flow Properties of Water Additive Corn-Cob-Mix for Handling by Pump (수분(水分)첨가된 옥수수(Corn-Cob-Mix)의 펌프 운송(運送) 시(時)의 유체성질(流體性質) 구명(究明))

  • Oh, I.H.;Heege, H.J.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.1
    • /
    • pp.33-40
    • /
    • 1989
  • The flow properties of water added com-cob-mix(CCM) were studied in order to provide basic information for designing its pumping system. For the study, a model system similar to actual situation was constructed. From the experiment, it can be concluded that the flow properties of the water added CCM has close relationship with its moisture content as follows; 1. The pressure drop caused by friction was very low when the moisture content of water added CCM was more than 70%. However, when the moisture content of the material is about 60%, the pressure drop increases up to 10 kPa/m at low pumping speed, and 20 kPa/m at high pumping speed, respectively. 2. The water added CCM having about 65% moisture content showed pseudo-plastic flow characteristics. 3. As the moisture content of the material decreases, the shear stress increases more rapidly than the shear rate does. Finally, below approximately 60% moisture, the shear stress becomes a linear relationship with the shear rate. 4. It was possible to pump the material having the moisture content down to 58% through a pipe having 80 mm diameter by a pump operating at 234 rpm. However, by either increasing the diameter of the pipe or decreasing the pumping speed, it can be possible to pump the material having lower moisture content than 55%.

  • PDF

Geochemistuy of the Borehole Groundwater from Volcanic Rocks in the Northeastern Part of Yeosu Area (여수 북동부 화산암 지역 시추공 지하수의 지화학 특성)

  • 고용권;김경수;배대석;김천수;한경원
    • Economic and Environmental Geology
    • /
    • v.34 no.3
    • /
    • pp.255-269
    • /
    • 2001
  • The geochemical studies on groundwater in the borehole, which is straddled by multi-packer (MP) system, were carried out from a volcanic terrain in the Yeosu area. The pH of groundwater collected from selected sections in the MP-installed borehole is much higher (up to 9.6) than that of the borehole groundwater (7.0-7.9) collected using conventional pumping technique. Hydrochemistry shows that the groundwater has a typical chemical change with increasing sampling depth, suggesting that the groundwater is evolved through water-rock interaction along the fracture-controlled flow paths. The groundwater from the deeper part (138-175 m below the surface) in borehole KI is characterized by the Ca-C11 type with high Ca (up to 160 mg/L) and Cl (up to 293 mg/L) contents, probably reflecting seawater intrusion. The groundwater also has high sodium and sulfate contents compared to the waters from other boreholes. These observed groundwater chemistry is explained by the cation exchange, sulfide oxidation, and mixing process with seawater along the flow path.

  • PDF

Water-hammer in the Pump Pipeline System with and without an Air-Chamber (에어챔버 설치에 따른 펌프관로계의 수격현상)

  • Lee, Sun-Kon;Yang, Cheol-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • When the pumps stopped in the operation by the power failure, the hydraulic transients take place in the sudden change of a velocity of pipe line. Each and every water hammer problem shows the critical stage to be greatly affected the facts of safety and reliability in case of power failure. The field tests of the water hammer executed at Cheong-Yang booster pump station having an air chamber. The effects were studied by both the practical experiments and the CFD(Computational Fluid Dynamics : Surge 2008). The result states that the system with water hammering protection equipment was much safer when power failure happens. The following data by a computational fluid dynamic analysis are to be shown below, securing the system stability and integrity. (1) With water hammering protection equipment. (1) Change of pressure : Up to $15.5\;kg/cm^2$ in contrary to estimating $16.88\;kg/cm^2$. (2) Change rate of water level : 52~33% in contrary to estimating 55~27%. (3) Note that the operational pressure of pump runs approx. 145 m, lowering 155 m of the regularity head of pump. (4) Note that the cycle of water hammering delays from 80 second to 100 second, together with easing the function of air value at the pneumatic lines. (2) Change of pressure without water hammering protection equipment : Approximate $22.86\;kg/cm^2$. The comprehensive result says that the computational fluid dynamics analysis would match well with the practical field-test. It was able to predict Max. or Min. water hammering time in a piping system. This study aims effectively to alleviate water hammering in a pipe line to be installed with air chamber at the pumping station and results in making the stability of pump system in the end.

Analysis of Female Windsurfers' Performance Using Global Positioning System Information During Competitions (여자 윈드서핑 선수의 경기 중 Global Positioning System 정보를 활용한 경기력 분석)

  • Chun, Sa Bin;Park, Jong Chul;Park, Sang Ha;Kim, Jin Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.3
    • /
    • pp.162-167
    • /
    • 2021
  • Objective: This study aimed to identify the different wind speed categories and competitive level among windsurfers through GPS variables to provide the useful information on the development of training programs for enhancing windsurfers' performance. Method: Data from 69 female athletes who participated in 27 races during the 2018-2019 windsurfing season were used for the analysis. Average board speed, total race time, total distance, upwind race time, downwind race time, beam reach race time were collected through GPS. Unconfirmed data were excluded along with penalty point data. The wind conditions were classified as light, light to medium, medium, medium to heavy, and heavy wind, the competitive levels were classified as level 1, level 2, and level 3. Results: As for the average board speed, the level 1 or level 2 group showed higher board speed than the level 3 group in all wind conditions except for the light wind. The total race time and upwind race time showed less time in level 1 or level 2 group than level 3 group in all wind conditions. The total distance, downwind race time and beam reach race time showed less distance and time in level1 group than level 3 group under sufficient wind conditions. Conclusion: Our results show that the aerobic capacity to sustain pumping during upwind course in wind conditions below 15 kts effects performance. In wind conditions of 15 kts or more, indicated that the board control for the fast board speed and small distance required during up, down, beam reach courses had an effect on competition performance. This information can be provided to windsurfers and coaching as basic data for training programs to improve performance.

The Study on the Increased Causes of Chloride ($Cl^{-}$) Concentration of the Samyang 3rd Pumping Station in Cheju Island (제주도 삼양 3수원지의 염소이온농도 상승 원인에 관한 연구)

  • 이성복;김구영;한소라;한정상
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.85-94
    • /
    • 1997
  • The study is aimed to find out the causes of rapidly increasing chloride (Cl$^{-}$) concentration of the Samyang 3rd pumping station originated from coastal springs of Cheju since January 1996. The study results show that it was caused by following complicated natural and anthropogenic effects. Due to severe draught in 1996 with total rainfall of only 41.7% of annual mean of the last 36 years (1991 to 1995), it creates firstly), significant decrease of the spring discharges as well decline of the groundwater level at the site . Sea water level was in general 4.4 cm to 12.4 cm higher than the groundwater level of the site during 2 to 3.8 hours at each high tide. Those higher potential head of sea water motivates the sea water intrusion into the fresh water lens through the permeable clinkers and fracture zones situated beneath the existing grouted zone which was installed to a maximum 10 m below the ground water surface, The repeated expansion and contraction of the fresh water lens occurred by periodic changes of the sea water level at high and low tide accelerates secondly the enlargement of the transition zone between the fresh and sea water at the site. The decrease of recharge amount by rainfall shortage creates thirdly the reverse flow at the interface of sea water and groundwater. The repeated groundwater extraction of 2790${\pm}$450 $m^3$d$^{-1}$ at the time of low tide, when the fresh water lens of the sire is under the contraction stare, makes additional drawdown of the ground water level and induces the upconing of salt water into the fresh water lens. The duration of spring discharge whose Cl concentration is less than 150 mg/1 at the low tide measured at the nearby springs was about two hours with discharge rate of 532 $m^3$d$^{-1}$ and after that Cl$^{-}$ concentration is increased up to more than 1900 mg/ι.eased up to more than 1900 mg/L.

  • PDF

Iron Extraction Characteristics of Sediment Samples from a River Bank Filtration Site (강변 여과 취수 지역 퇴적물의 철 화학종 추출 특성)

  • Hyun, Sung Pil;Moon, Hee Sun;Yoon, Pilsun;Kim, BoA;Ha, Kyoochul
    • Journal of the Mineralogical Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.129-138
    • /
    • 2013
  • River bank filtration has been considered as a promising alternative water management scheme, in which groundwater is extracted from an aquifer near a river after infiltration of the river water into the aquifer, thereby improving and maintaining the quality of water recovered. Iron (Fe) associated with sediment in contact with groundwater and infiltrating surface water is an important factor in determining the quality of water recovered from the pumping wells in river bank filtration. This study reports the results of Fe speciation in the aquifer sediment samples collected from different depths at the river bank filtration site in Changwon, studied using four different chemical extraction methods, namely, ferrozine, oxalate, HCl, and DCB methods. Overall, the results show that Fe(II) as well as the total Fe content decreases with depth down to ~20 m and then increases further below. This trend is consistent with the redox characteristics suggested by visual observation. The silt/clay size fraction (${\phi}$ < 62.5 ${\mu}M$) has up to 2~10 times more Fe compared with the sand size fraction (62.5 ${\mu}M$ < ${\phi}$ < 2 mm), depending on the extraction method. Of the four extraction methods, DCB solution extracted the most Fe from the sediment samples. The amounts of Fe extracted by the different extraction methods can be a good indicator of the redox conditions along the depth of the aquifer.