• Title/Summary/Keyword: QAC

Search Result 25, Processing Time 0.026 seconds

Antioxidant and Antidiabetic Activities of Extracts from Quercus serrata Thunb and Q. acutissima Carruther (도토리(Quercus serrata Thunb)와 상수리(Quercus acutissima Carruther) 추출물의 항산화와 항당뇨 활성 연구)

  • Chu, Ji-Hye;Choi, Jin-Hee
    • Journal of the Korean Society of Food Culture
    • /
    • v.36 no.5
    • /
    • pp.522-529
    • /
    • 2021
  • This study was conducted to analyze the antioxidant and antidiabetic activities of acorns according to the types of Quercus serrata Thunb (QST) and Q. acutissima Carruther (QAC). The total polyphenol contents of the extracts from QST and QAC were 220.59 and 320.96 mg GAE/g, respectively. The content of total polyphenol of QAC was higher than that of QAC (p<0.001). DPPH (2,2 Diphenyl 1 picrylhydrazyl) radical scavenging activity, reducing power and superoxide dismutase (SOD)-like activity were increased in a concentration-dependent manner by both acorn extracts, and QAC showed high activity in all antioxidant experiments (p<0.05). The inhibitory activities of α-glucosidase and α-amylase were also increased in a concentration-dependent manner, and QAC showed higher inhibitory activity than QST (p<0.05). Our study indicates that QST and QAC are functional food materials with high antioxidant and antidiabetic activities. In addition, QAC has a higher physiological activity than QST.

Disinfection of various materials with 3-(trimethoxysilyl)-propyldimethyloctadecyl ammonium chloride in hatchery facilities

  • Kim, Yu-Jin;Kim, Jun-Beom;Song, Chang-Seon;Nahm, Sang-Soep
    • Animal Bioscience
    • /
    • v.35 no.4
    • /
    • pp.631-637
    • /
    • 2022
  • Objective: Surface disinfection is important in the proper running of livestock farms. However, disinfection of farm equipment and facilities is difficult because they are made of different materials, besides having large surface areas and complex structures. 3-(trimethoxysilyl)-propyldimethyloctadecyl ammonium chloride (Si-QAC) is a quaternary ammonium salt-based disinfectant that attaches to various surfaces by forming covalent bonds and maintains its disinfecting capacity for a considerable time. Our aim was to evaluate the potential use of Si-QAC for disinfection of farm equipment and facilities. Methods: The short- and long-term antimicrobial and antiviral effects of Si-QAC were evaluated in both laboratory and farm settings using modified quantitative assessment method based on the standard operating procedures of the United States Environmental Protection Agency. Results: Si-QAC was highly effective in controlling the growth of the Newcastle disease virus and avian pathogenic Escherichia coli. Electron microscopy revealed that the mechanism underlying the disinfection activity of Si-QAC was associated with its ability to damage the outer membrane of the pathogen cells. In the field test, Si-QAC effectively reduced viral contamination of surfaces of equipment and space. Conclusion: Our results suggest that Si-QAC has great potential as an effective chemical for disinfecting farm equipment and facilities. This disinfectant could retain its disinfection ability longer than other commercial disinfectants and contribute to better farm biosecurity.

(A Study on the Design of Analog Converter Using Neuron MOS) (뉴런모스를 이용한 아날로그 변환기 설계에 관한 연구)

  • Han, Seong-Il;Park, Seung-Yong;Kim, Heung-Su
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.3
    • /
    • pp.201-210
    • /
    • 2002
  • This paper describes a 3.3 (V) low power 4 digit CMOS quaternary to analog converter (QAC) designed with a neuron MOS($\upsilon$MOS) down literal circuit block and cascode current mirror source block. The neuron MOS down literal architecture allows the designed QAC to accept not only 4 level voltage inputs, but also a high speed sampling rate quaternary voltage source LSB. Fast settling time and low power consumption of the QAC are achieved by utilizing the proposed architecture. The simulation results of the designed 4 digit QAC show a sampling rate of 6(MHz) and a power dissipation of 24.5 (mW) with a single power supply of 3.3 (V) for a CMOS 0.35${\mu}{\textrm}{m}$ n-well technology.

A Study on the Improvement of Antimicrobial Activity and Crease Resistance of Korean Traditional Hansan Ramie Fabrics (한국 전통한산모시의 항균성 및 방추도 향상에 관한 연구)

  • Kim, Ho Jung;Choi, Jae Hyeok;Kim, Han Do;Park, Cha Cheol
    • Textile Coloration and Finishing
    • /
    • v.6 no.4
    • /
    • pp.1-8
    • /
    • 1994
  • To improve the antimicrobial activity and crease resistance of Korean traditional Hansan ramie fabrics, partially saponified polyethylene(PPS) was used as a softening water repellent agent and 3-(trimethoxysilyl)propyl dimethyl octadecyl ammonium chloride(QAC) as a antimicrobial agent. The antimicrobial activity was effective by treatments of PPS, QAC and PPS/QAC for shake flask test. For the halo test, PPS/QAC showed good antimicrobial activity. It was found that the desirable composition of H$_{2}$O/PPS/QAC is 98/1/1 for improving the antimicrobial activity and crease resistance of the fabrics.

  • PDF

MVL Data Converters Using Neuron MOS Down Literal Circuit (뉴런모스 다운리터럴 회로를 이용한 다치논리용 데이터 변환기)

  • Han, Sung-Il;Na, Gi-Soo;Choi, Young-Hee;Kim, Heung-Soo
    • Journal of IKEEE
    • /
    • v.7 no.2 s.13
    • /
    • pp.135-143
    • /
    • 2003
  • This paper describes the design techniques of the data converters for Multiple-Valued Logic(MVL). A 3.3V low power 4 digit CMOS analog to quaternary converter (AQC) and quaternary to analog converter (QAC) mainly designed with the neuron MOS down literal circuit block has been introduced. The neuron MOS down literal architecture allows the designed AQC and QAC to accept analog and 4 level voltage inputs, and enables the proposed circuits to have the multi-threshold properity. Low power consumption of the AQC and QAC are achieved by utilizing the proposed architecture.

  • PDF

QoS Aware Cross-layer MAC Protocol in wireless Sensor Networks (무선 센서 네트워크에서 QoS를 인지하는 Cross-layer MAC 프로토콜)

  • Park, Hyun-Joo;Kim, Seong-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2811-2817
    • /
    • 2010
  • In this paper we propose the QAC-MAC that supports Quality of Service(QoS) and saves energy resources of the sensor node, and hence prolonging the lifetime of the sensor network with multiple sink nodes. Generally, the nodes nearest to the sink node often experience heavy congestion since all data is forwarded toward the sink through those nodes. So this critically effects on the delay-constraint data traffics. QAC-MAC uses a hybrid mechanism that adapts scheduled scheme for medium access and scheduling and unscheduled scheme based on TDMA for no data collision transmission. Generally speaking, characteristics of the real-time traffic with higher priority tends to be bursty and has same destination. QAC-MAC adapts cross-layer concept to rearrange the data transmission order in each sensor node's queue, saves energy consumption by allowing few nodes in data transmission, and prolongs the network lifetime.

Effectiveness of calcium hypochlorite, quaternary ammonium compounds, and sodium hypochlorite in eliminating vegetative cells and spores of Bacillus anthracis surrogate

  • Yim, Jin-Hyeok;Song, Kwang-Young;Kim, Hyunsook;Bae, Dongryeoul;Chon, Jung-Whan;Seo, Kun-Ho
    • Journal of Veterinary Science
    • /
    • v.22 no.1
    • /
    • pp.11.1-11.7
    • /
    • 2021
  • Background: The spore-forming bacterium Bacillus anthracis causes anthrax, an often-fatal infection in animals. Therefore, a rapid and reliable strategy to decontaminate areas, humans, and livestock from B. anthracis is very critical. Objectives: The aim of this study was performed to evaluate the efficacy of sodium hypochlorite, calcium hypochlorite, and quaternary ammonium compound (QAC) sanitizers, which are commonly used in the food industry, to inhibit spores and vegetative cells of B. anthracis surrogate. Methods: We evaluated the efficacy of sodium hypochlorite, calcium hypochlorite, and a QAC in inhibiting vegetative cells and spores of a B. anthracis surrogate. We treated a 0.1-mL vegetative cell culture or spore solution with 10 mL sanitizer. The samples were serially diluted and cultured. Results: We found that 50 ppm sodium hypochlorite (pH 7), 1 ppm calcium hypochlorite, and 1 ppm QAC completely eliminated the cells in vegetative state. Exposure to 3,000 ppm sodium hypochlorite (pH 7) and 300 ppm calcium hypochlorite significantly eliminated the bacterial spores; however, 50,000 ppm QAC could not eliminate all spores. Conclusions: Calcium hypochlorite and QAC showed better performance than sodium hypochlorite in completely eliminating vegetative cells of B. anthracis surrogate. QAC was ineffective against spores of the B. anthracis surrogate. Among the three commercial disinfectants tested, calcium hypochlorite most effectively eliminated both B. anthracis vegetative cells and spores.

A QoS-aware Adaptive Coloring Scheduling Algorithm for Co-located WBANs

  • Wang, Jingxian;Sun, Yongmei;Luo, Shuyun;Ji, Yuefeng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.12
    • /
    • pp.5800-5818
    • /
    • 2018
  • Interference may occur when several co-located wireless body area networks (WBANs) share the same channel simultaneously, which is compressed by resource scheduling generally. In this paper, a QoS-aware Adaptive Coloring (QAC) scheduling algorithm is proposed, which contains two components: interference sets determination and time slots assignment. The highlight of QAC is to determine the interference graph based on the relay scheme and adapted to the network QoS by multi-coloring approach. However, the frequent resource assignment brings in extra energy consumption and packet loss. Thus we come up with a launch condition for the QAC scheduling algorithm, that is if the interference duration is longer than a threshold predetermined, time slots rescheduling is activated. Furthermore, based on the relative distance and moving speed between WBANs, a prediction model for interference duration is proposed. The simulation results show that compared with the state-of-the-art approaches, the QAC scheduling algorithm has better performance in terms of network capacity, average delay and resource utility.

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

Effect of quaternary ammonium compounds on microbial contamination levels in dental clinics (치과 진료실의 미생물 오염도에 대한 4차 암모늄 화합물의 효과)

  • Baik, Sae Yun;Park, YounJung;Choi, Seung Ho;Kim, Hee Jae;Kim, Seong Taek
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.55-60
    • /
    • 2020
  • The aim of this study was to investigate the change of microbial contamination levels in the different areas and at the different time points after application of a quaternary ammonium compound (QAC) that has mechanical antimicrobial effect. The microbial contamination levels were measured in three different areas; unit chair handle, spit sink area and hand piece holder at different time points using adenosine triphosphate (ATP) monitoring system and ATP surface test kit. Hand piece holder showed the highest level of microbial contamination. In most of the clinics, QAC significantly reduced the levels of microbial contamination, and maintained antimicrobial activity for 4 to 6 months. QAC may be used effectively in dental clinics due to the duration of antimicrobial effect and the minimal exposure of chemicals and further studies are needed with large sample size.