• Title/Summary/Keyword: Quantitative ultrasound

Search Result 134, Processing Time 0.045 seconds

Survey on Usage of Korean Quantitative Ultrasound for Proposing Quantitative Ultrasound Quality Control Guideline (초음파골밀도측정기 정도관리 방안제시를 위한 한국 초음파골밀도 사용현황 조사)

  • Jeong, Yoon-Ji;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.329-337
    • /
    • 2018
  • This study was investigated quantitative ultrasound (QUS) usage in Korea for the QUS quality control guidelines. A total of 344 questionnaires collected from July 24th to August 25th 2017 were analyzed. Questionnaires were created through user interviews, expert group advice, literature review and field observation. As a result of the general characteristics of quantitative ultrasound holding amounted to 81.98% of clinic and 6.69% of hospitals. The main user was radio-logical technologists as 31.39%. The contact methods of the gel pad (balloon) were the most used at 56.68% and the scan region was 91.9% of calcaneus. The quantitative ultrasound quality control cycle was 67.37% when the abnormality was found in the equipment, and 63.66% when the accuracy control was implemented according to the manual. The phantoms of QUS were 34.30% of the manufacturer's own phantoms. User of QUS had never received education for quality control of quantitative ultrasound as 62.20%. This study was expected to be useful when creating detailed quality control guidelines in the future, as well as guidelines for the quality control of Korea's standard quantitative ultrasound.

Comparative Study of Contrast-Enhanced Ultrasound Qualitative and Quantitative Analysis for Identifying Benign and Malignant Breast Tumor Lumps

  • Liu, Jian;Gao, Yun-Hua;Li, Ding-Dong;Gao, Yan-Chun;Hou, Ling-Mi;Xie, Ting
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.19
    • /
    • pp.8149-8153
    • /
    • 2014
  • Background: To compare the value of contrast-enhanced ultrasound (CEUS) qualitative and quantitative analysis in the identification of breast tumor lumps. Materials and Methods: Qualitative and quantitative indicators of CEUS for 73 cases of breast tumor lumps were retrospectively analyzed by univariate and multivariate approaches. Logistic regression was applied and ROC curves were drawn for evaluation and comparison. Results: The CEUS qualitative indicator-generated regression equation contained three indicators, namely enhanced homogeneity, diameter line expansion and peak intensity grading, which demonstrated prediction accuracy for benign and malignant breast tumor lumps of 91.8%; the quantitative indicator-generated regression equation only contained one indicator, namely the relative peak intensity, and its prediction accuracy was 61.5%. The corresponding areas under the ROC curve for qualitative and quantitative analyses were 91.3% and 75.7%, respectively, which exhibited a statistically significant difference by the Z test (P<0.05). Conclusions: The ability of CEUS qualitative analysis to identify breast tumor lumps is better than with quantitative analysis.

A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence (인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구)

  • Yeon Jin, Im;Ho Seong, Hwang;Dong Hyun, Kim;Ho Chul, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.390-398
    • /
    • 2022
  • Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative evaluation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.

Age Related Analysis of Ultrasound Images of Normal Skeletal Muscle (연령에 따른 정상 골격근의 초음파 영상 분석)

  • Jeong, Jin-Gyu;Kim, Kye-Yoep;Kim, Jong-Man;Ki, Tae-Youl
    • Physical Therapy Korea
    • /
    • v.13 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • Since ultrasound has different reflections depending on components of organization, analysis of ultrasound images of skeletal muscle can offer both quantitative and qualitative reports as concerns skeletal muscle structure. This study is focused on the ultrasound method for evaluating the structural characteristics of skeletal muscle and also conducted to examine its practicality. After obtaining images of the elbow flexors from an ultrasound image device with 88 normal subjects whose ages were between twenty and seventy years old (44 men and 44 women), muscular density and white area index (WAI) which indicated structural characteristics of skeletal muscle were analyzed with gray scale analysis. The study examined correlations between subject's age and items which obtained from measuring ultrasound images and the differences in relations to sex and age. Muscular density and WAI had a high correlation with age and were significantly increased in men and women with greater age. The quantitative evaluation method of skeletal muscle structure which analyzed the ultrasound images has high practicality because it is a non-invasive method which complements physical therapy diagnosis and research methods and promotes functionality evaluation.

  • PDF

Fatty Liver Analysis through Quantitative Measurement Study of Ultrasonography Images (초음파 검사 영상의 정량적인 측정 연구를 통한 지방간 분석)

  • Hye-Ri, Chun;Hyon-Chol, Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.927-934
    • /
    • 2022
  • This study attempted to find out the degree of agreement between ultrasound image findings along with analysis of attenuation index and scatter distribution index values within tissues through quantitative measurement analysis using liver ultrasound images. From August 2022 to October 2022, liver ultrasound was performed on 45 patients who were suspected of having fatty liver and who received a prescription for liver ultrasound. As a result of the study, as a result of analyzing the agreement between the ultrasound image findings and the tissue attenuation index, the Kappa value was 0.82 (p<0.05), showing a very high agreement between the two examination methods. In addition, as a result of the agreement analysis between the ultrasound image findings and the scatter distribution index in the tissue, the Kappa value was 0.642 (p<0.05), showing high agreement between the two examination methods. At the time of fat liver prediction, the use of liver ultrasound findings and quantitative ultrasonography techniques, such as intra-tissue attenuation index and intra-tissue scatter distribution index, may be helpful in determining the degree of progression of fatty liver patients.

Analysis of sEMG Median frequency and Ultrasound Image Echodensity of Normal Skeletal Muscle (정상 골격근의 근전도 중앙주파수 및 초음파 영상 밀도 분석)

  • Jeong, Jin-Gyu;Kim, Yong-Nam;Hwang, Tae-Yeun;Lee, Jeong-Woo;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.1
    • /
    • pp.83-94
    • /
    • 2006
  • Purpose: This study conducts quantitative evaluation or structural and functional characteristics or normal skeletal muscle with ultrasound image and surface electromyography, and is to provide basic materials for utilizing ultrasound image analysis in physical therapy diagnosis and assessment of skeletal muscle. Methods: Measurement of three stages was conducted with 88 normal adults between their twenties and seventies, correlations and differences using collected data according to age and gender were compared and correlations among measured items were analyzed and then the following conclusions were obtained. Results: Analysis of ultrasound image of normal skeletal muscle showed that density, median frequency had the closest relations with age. In addition, it was found that there were high correlations between density explaining structural characteristics of skeletal muscle and median frequency explaining functional characteristics. Conclusion: Analysis of ultrasound image makes complex evaluation of structure and function of skeletal muscle possible when it is connected with functional evaluation method using physical measurement surface electromyography as well as quantitative evaluation of structural changes of skeletal muscle and is effective in complementing physical therapy diagnosis centering around functionality evaluation.

  • PDF

Extraction Method of Ultrasound Spectral Information using Phase-Compensation and Weighted Averaging Techniques (위상 보상과 가중치 평균을 이용한 의료 초음파 신호의 주파수 특성 추출 방법)

  • Kim, Hyung-Suk;Yi, Joon-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.959-966
    • /
    • 2010
  • Quantitative ultrasound analysis provides fundamental information of various ultrasound parameters using spectral information of the short-gated radiofrequency(RF) data. Therefore, accurate extraction of spectral information from backscattered RF signal is crucial for further analysis of medical ultrasound parameters. In this paper, we propose two techniques for calculating a more accurate power spectrum which are based on the phase-compensation using the normalized cross-correlation to minimize estimation errors due to phase variations, and the weighted averaging technique to maximize the signal-to-noise ratio(SNR). The simulation results demonstrate that the proposed method estimates better results with 10% smaller estimation variances compared to the conventional methods.

Association Between Physical Activity and Quantitative Ultrasound in a Rural Population (신체활동과 골초음파지표와의 연관성)

  • Kim, Seung-Joon;Shin, Min-Ho;Kweon, Sun-Seog
    • Physical Therapy Korea
    • /
    • v.12 no.2
    • /
    • pp.20-27
    • /
    • 2005
  • Osteoporosis is characterized by low bone mass and the microarchitectural deterioration of bone tissue with a consequent increase in bone fragility and susceptibility to fracture. It has been suggested that speed of sound (SOS) and broadband ultrasound attenuation (BUA) of quantitative ultrasound sonography (QUS) may provide information about not only bone density but also the microarchitecture and elastic properties of bone. Physical inactivity reduced mechanical usage and it made process to the bone changes. This study aimed to association between the physical activity and the QUS parameters in 1305 (593 men, 712 women) aged 20 years over in a rural population. Two QUS parameters, BUA (p=.23) and SOS(p=.73) were measured at the right calcaneus of postmenopausal women, no significant associations were observed between sports index and SOS and BUA. These results suggest that work, non-sports leisure physical activity (p<.01) have a significant influence on QUS parameters in a rural population. Physical activity are meaningful predictor of QUS parameters of the calcaneus in a rural population.

  • PDF

Evaluation of the Resolution Characteristics by Using ATS 535H Phantom for Ultrasound Medical Imaging (초음파 의료영상에서 ATS 535H 팬텀을 이용한 해상력 특성 평가)

  • Jung-Whan, Min;Hoi-Woun, Jeong;Hea-Kyung, Kang
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.15-21
    • /
    • 2023
  • This study was purpose to assessment of the resolution characteristics by using ATS 535H Basic quality assurance (QA) phantom for ultrasound. The ultrasound equipment was used Logiq P6 (Ultrasound, GE Healthcare System, Chicago, IL, USA). And the ultrasound transducer were used Convex 4C (4~5.5 MHz), Linear 11L (10~13 MHz), Sector 3SP (3~5.5 MHz) probe. As for the noise power spectrum (NPS) comparison results by using ATS 535H Basic QA ultrasound phantom and Convex 4C, Linear 11L, Sector 3SP probe. The NPS value of the Convex 4C probe image was 0.0049, Linear 11L probe image was 0.0049, Sector 3SP probe image was 0.1422 when the frequency is 1.0 mm-1. The modulation transfer function (MTF) comparison results by using ATS 535H Basic QA ultrasound phantom and Linear 11L probe the MTF value of the 3 cm focus image was 0.7511 and 4 cm focus image was 0.9001 when the frequency is 1.0 mm-1. This study was presented characteristics of spatial resolution a quantitative evaluation methods by using ultrasound medical images for QA of ultrasound medical QA phantom. The quality control (QC) for equipment maintenance can be efficiently used in the clinic due to the quantitative evaluation of the NPS and MTF as the standard methods. It is meaningful in that it is applied mutatis mutandis and presented the results of physical resolution characteristics of the ultrasound medical image.

Exploring and calibrating local curvature effect of cortical bone for quantitative ultrasound (QUS)

  • Chen, Jiangang;Su, Zhongqing;Cheng, Li;Ta, De-An
    • Structural Engineering and Mechanics
    • /
    • v.48 no.4
    • /
    • pp.501-518
    • /
    • 2013
  • Apart from thinning of cortical layers, the local bone curvature, varying along bone periphery, modulates ultrasound waves as well, which is however often underestimated or overlooked in clinical quantitative ultrasound (QUS). A dedicated three-dimensional finite element modelling technique for cortical bones was established, for quantitatively exploring and calibrating the effect of local curvature of cortical bone on ultrasound. Using a correlation-based mode extraction technique, high-velocity group (HVG) and low-velocity group (LVG) wave modes in a human radius were examined. Experimental verification using acrylic cylinders and in vitro testing using a porcine femur were accomplished. Results coherently unravelled the cortical curvature exerts evident influence on bone-guided ultrasound when RoC/${\lambda}$ <1 for HVG mode and RoC/${\lambda}$ <2 for LVG mode (RoC/${\lambda}$: the ratio of local bone curvature radius to wavelength); the sensitivity of LVG mode to bone curvature is higher than HVG mode. It has also been demonstrated the local group velocity of an HVG or LVG mode at a particular skeletal site is equivalent to the velocity when propagating in a uniform cylinder having an outer radius identical to the radius of curvature at that site. This study provides a rule of thumb to compensate for the effect of bone curvature in QUS.