• Title/Summary/Keyword: RELAY Module

Search Result 69, Processing Time 0.039 seconds

Implementation and Test of RELAY Module for Multiple SNS Channels (다중 SNS 채널을 위한 RELAY 모듈의 구현 및 실험)

  • Ahn, Heui-Hak;Lee, Dae-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.4
    • /
    • pp.362-369
    • /
    • 2018
  • In this paper, we propose a procedure to multiple SNS channels automatic streaming through multiple output channels including the output channel of an external streaming server. The multiple SNS channels automatic streaming server includes an output management module for controlling the transmission of video contents to RELAY module that establish two or more output channels. In this paper, we experimented by separate with HD and FHD video using RELAY module in multiple SNS channel automatic streaming. In stream modules using RELAY module of HD video, when the publisher client and the player client and the RELAY module are 1 channel, the occupancy rate of CPU is 0.6% and the occupancy rate of heap memory is 0.3%(20 Mbyte). When the publisher client and the player client and the RELAY module are 183 channels, the occupancy rate of CPU is 99.9% and the occupancy rate of heap memory is 45.8%(3.7Gbyte). Therefore, the paper is not limited to the size of the streaming server by extending the output channel from which the video is transmitted to the output channel of the external streaming server. And a process of allocating an output channel of an external streaming server to an output channel through which an video is transmitted can be easily performed, so that an efficient output channel management can be performed even when a plurality of videos are transmitted.

The RELAY Module Design of Multi SNS Channel Auto Streaming Server (다중 SNS 채널 자동 스트리밍 서버의 RELAY 모듈 설계)

  • Ahn, Heuihak;Lee, Daesik
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.4
    • /
    • pp.213-219
    • /
    • 2017
  • Streaming server is that an image produced in real time or a file form of image produced ahead consists of SNS service, and the relay module of streaming server includes output management module that set an output channel more than 2 and control transmission of video content. This thesis intends to suggest how to stream through plural output channel that contains output channel of external streaming server using relay module and do streaming provided to terminal receiving image, and streaming server, streaming system for this. Thus, by extending output channel sending out image to output channel of external streaming server, the scale of streaming server is not limited and the process allotting external streaming server into output channel sending the image becomes simple, so management of output channel becomes efficient even when sending several images.

An Experimental Study on the Noise Reduction Method of HEV-relay Module (하이브리드 자동차용 계전기 모듈의 소음저감에 관한 실험적 연구)

  • Seo, Jae-Yong;Kim, Won-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.10
    • /
    • pp.77-83
    • /
    • 2010
  • In this paper, the noise of HEV(hybrid electric vehicle)-relay module during the turn-on and turnoff switching is experimentally analyzed and an effective method is proposed to reduce the impact noise. First, enclosure methods of 100A relay part with urethane and silicon are tested to find out a better material to isolate the noise. This result shows that the urethane is a better for the noise isolation of relay, so the relays enclosed by urethane are installed in the relay module. Second, the noise of HEV-relay module is analyzed experimentally to identify the noise generation mechanism. From this result, it is found that the vibration transmitted to battery pack through bolt generates the structural borne noise with the frequency band of 200~2000 Hz, which is more serious when the switch is turned off. Finally, the direction of switching and the joint structure are modified in order to isolate the vibration transmitted to battery back. Both methods are very effective to reduce the switching noise.

Implementation of VLC Relay Module to Improve Communication Disconnection Phenomenon and Coverage Expansion in Non-Line-of-Sight Area (비가시선 영역의 통신 단절 현상 개선과 커버리지 확장을 위한 VLC 릴레이 모듈 구현)

  • Lee, Sang-gwon;Lee, Dae-hee;Oh, Chang-heon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.140-146
    • /
    • 2018
  • Recently, VLC(Visible Light Communication) fusing with LED(Light Emitting Diode) used in indoor lighting and wireless communication technology has attracted attention. However, the VLC can communicate only within the coverage to measure the optical signal and the communication disconnection phenomenon is occur in the NLoS(Non-Line-of-Sight) area. In this paper, we propose VLC relay module to extend the coverage of VLC and improve the communication disconnection phenomenon in NLoS area. The proposed VLC relay module transmits the packet received from the transmitter to the VLC relay module and receiver. The experiment was carried out by installing one VLC transmitter and three VLC relay modules, communication coverage expansion and the improvement of communication disconnection phenomenon in the NLoS were confirmed by the increase of the VLC relay module. Also, we confirmed that the optical signal measurement performance is improved 2.4 times by using the dual sampling method.

A Study on The Development and Function Test of Digital Transformer Protection Relay Using The Induced Voltage (유기전압비를 이용한 디지털형 변압기 보호계전기 개발 및 성능시험에 관한 연구)

  • Jung, Sung-Kyo;Lee, Jae-Kyung;Kim, Han-Do;Choi, Dae-Gil;Kang, Yong-Chul;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.216-218
    • /
    • 2001
  • The transformer role is very important in power system operation and control; also its price is very expensive. Therefore many kinds of the efforts for transformer protection have been executed. So for as, current differential relay(87) has been mainly used for transformer protection. But current differential relaying method has several troubles as followings. Differential current can be occurred by transformers inrush current between winding1 and winding2 of transformer when transformer is initially energized. Also harmonic restrained element used in current differential relaying method is one of the causes of relays mal-operation because recently harmonics in power system gradually increase by power switching devices(SVC, FACTS, DSC, etc). Therefore many kinds of effort have been executed to solve the trouble of current differential relay and one of them is method using ratio of increment of flux linkages(RIFL) of the primary and secondary windings. This paper introduces a novel protective relay for power transformers using RIFL of the primary and secondary windings. Novel protective relay successfully discriminates between transformer internal faults and normal operation conditions including inrush and this paper includes real time test results using RTDS(Real Time Digital Simulator) for novel protective relay. A novel protective relay was designed using the TMS320C32 digital signal processor and consisted of DSP module. A/D converter module, DI/DO module, MMI interface module and LCD display module and developed by Xelpower co., Ltd.

  • PDF

Development of an Under-Voltage Relay Algorithm Module for a Network Based Protective Relay Simulator (네트워크 기반 보호계전기 시뮬레이터용 저전압 계전 알고리즘 모듈 구현)

  • Kim, Cheol-Hun;Min, Seung-Ki;Choi, Dong-Sung;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.370-371
    • /
    • 2011
  • This paper proposed an under-voltage relay algorithm module for a network based protective relay simulator. The simulation system is based on the client-server paradigm. The relaying simulator which consists of server-side relay models and user interface provides network-based simulation environment for a variety of protective relaying algorithms. The performance of the relay algorithm was verified by comparing the results of under-voltage relay algorithm in the simulator with the results of the C language implementation.

  • PDF

A Study On the Improvement Of Proset2000 by a Design Method Using the Uinfied Modelling Language (UML을 사용한 디자인 방법에 의한 계통보호 종합전산 프로그램의 개선에 관한 연구)

  • 최면송;현승호;오성민;오태욱
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.7-12
    • /
    • 2004
  • The role of protective relay with correct setting value is very important for the reliable operation of power : system. The setting process of a protective relay is difficult and requires hard work of calculations. Therefore, KEPCO as been using PROSET2000, a computer program system, in order to automate the setting process of protective relays in power transmission network since 2000. This system has a database and relay setting modules for each type of realy with coresponding Human and Computer Interaction(HCI). For the setting of a new type of relay, it require a new module, a HCI and a database table corresponding to the new relay. But it's update is not easy in case of new type of relay. This paper discussed the update method introducing a concept of Open Interface. It addressd a method to make a new HCI for new relay in view of object-oriented method using UML(Unified Modeling Language). Using the UML, we updated the PROSET2000. HCI screens for a new relay is generated automatically using the information of the new relay stored in the database. And, the database management module is upgraded to solve problems in manage and maintain the database in view of Open Interface.

Implementation of a Relay Module for Coverage Extension in Visible Light Communication (가시광 통신의 커버리지 확장을 위한 릴레이 모듈 구현)

  • Lee, Sang-Gwon;Lee, Jong-Sung;Oh, Chang-Heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.738-740
    • /
    • 2017
  • Visible light communication is a communication method using light, and it has advantage of ensuring security in a single space as compared with RF communication. However, in the area outside the visible line of the light, communication disconnection occurs. Therefore, this paper proposes a relay module to overcome the coverage extension and communication disconnection phenomenon of visible light communication. The proposed relay module transmits and receives data of visible light communication by sequentially transmitting data packets including target ID through adjacent visible light module. Through experimentation of data transmission, we confirmed the extension of the transmission range and the data reception in the area outside the line of sight.

  • PDF

A Design on the Digital Protective Relay System for Generator Fault Diagnosis (발전기 고장진단을 위한 디지털보호계전 시스템 설계)

  • Lee, Sung-Hwan;Jang, Nak-Won;Yi, Dong-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.717-718
    • /
    • 2008
  • We developed the protection program for the generator fault protection system and each module of the digital protective relay H/W for loading the protection program. The protective algorithm for the generator is 51, 51G/N, 46P/N, 47P/N, 50G/N, and 32, and we developed each fault protection program. And we must design high efficiency microprocessor, CT, and PT for realtime measuring, relaying and high accuracy of measurement, also. From now on digital protective relay must be operated with integrated management systems. For this point, we must load various industrial protocol on the digital protective relay. In this research, we developed each protective relay H/W module according to above conditions. And we designed real-time operating system in order that each protective algorithm is operated with realtime processing on the H/W system.

  • PDF

Development of an Over-Current Relaying Algorithm Module for a Network-Based Protective Relay Simulator (네트워크 기반 보호계전기 시뮬레이터용 과전류 계전 알고리즘 모듈 구현)

  • Park, Gun-Ho;Kim, Dong-Hee;Ko, Ja-Young;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.741-742
    • /
    • 2011
  • In this paper, an over-current relay algorithm module for a network-based protective relay simulator is proposed. The proposed protective simulator is based on the client-sever paradigm. The module composed of a server and user interface provides a network-based simulation environment.

  • PDF