• Title/Summary/Keyword: Radial Parameters

Search Result 566, Processing Time 0.024 seconds

The Effect of Sa-Am Stomach Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (위정격(胃正格) 자침이 정상 성인의 맥파(脈波)에 미치는 영향)

  • Choi, Joo Young;Kang, Jae Hui;Yim, Yun Kyong;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.6
    • /
    • pp.57-71
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am stomach tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Radial pulse were measured using 3 dimensional pulse imaging system(DMP-3000). 19 parameters that significantly changed were selected after comparing between acupuncture group and control group. Then, 19 parameters were analyzed before, immediately after, 30 minutes after and 60 minutes after acupuncture in acupucture group. Results : 1. Heart rate, pulse period, T/T1, T2/T, T4/T, T5/T, T-T4, (T-T4)/T and T4/(T-T4) significantly changed after acupuncture. 2. H1 Amplitude, H2 Amplitude, H4 Amplitude and H5 Amplitude significantly changed after acupuncture. 3. Area of Pulse Wave, Systolic Pulse Area, Diastolic Pulse Area and Area of W significantly changed after acupuncture. 4. AIx/HR significantly changed after acupuncture. Conclusion : Stomach Tonifying Acupuncture exerts an influence on radial pulse parameters. Further radial pulse change study on various acupuncture treatment is required.

The Effect of Sa-Am Lung Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (폐정격(肺正格) 자침이 촌관척(寸關尺) 맥파 변화에 미치는 영향)

  • Kim, Na-Yeon;Kang, Jae-Hui;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.17-29
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am lung tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Compared various parameters of radial pulse between two groups, and the significantly changed 16 parameters ware measured using 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after, and 60 minutes after acupuncture at Chon, Gwan, Cheok in acupucture group. Results : After lung tonifying acupuncture, radial pulse 16 parameters were showed changes significantly according to the time at each measuring location. 1. Heart rate, T2/T, T5, T5/T and W/T significantly decreased, W significantly increased. 2. Modulus of elasticity significantly decreased in left Cheok. 3. Amplitude of H4 significantly increased in left Gwan and right Cheok. 4. AIx, AIxHR significantly decreased in left Gwan and significantly increased in right Chon. 5. Area of pulse, area of W significantly increased in right Cheok. 6. Pulse energy, energy/min, EIx significantly decreased in left Cheok. 7. Maximum variation time of each parameter is showed different according to the parameter. Conclusions : Lung tonifying acupuncture exerts an influence on radial purse parameters. Further radial pulse change study on various acupuncture treatment is required.

Design Parametric Analysis of Radial Beam Coupling using Finite Element Analysis (유한요소 해석을 통한 레이디얼 빔 커플링의 설계인자 분석)

  • Lee, Chibum;Park, Yeong Il
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.537-543
    • /
    • 2013
  • In this paper, a novel radial beam coupling model was proposed and the design parameters were studied for the efficient transmission of torque. To develop a high performance radial beam coupling, an analytical way to predict the performance in design phase is required. One of the best ways to estimate the performance of the coupling without manufacturing is to evaluate the stress and torsional stiffness by building a finite element model with a special attention to the radial beam cutting part. For the best results of FEA, the material properties were obtained through testing. To verify the reliability of finite element model, the results of FEA were compared with the experiments. The main design parameters of radial beam cutting width, radial beam cutting depth, and radial beam cutting direction were considered for the performance of radial beam coupling.

Properties of Pulse Waveforms by Posture Changes : Standing, Sitting, Supine Posture (측정 자세의 변화에 따른 맥의 변화 특성 : 선 자세, 앉은 자세, 누운 자세)

  • Kown, Sun-Min;Kang, Hee-Jung;Lee, Sang-Hun;Yim, Yun-Kyoung;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.26 no.4
    • /
    • pp.13-22
    • /
    • 2009
  • Objectives : Informations on pulse diagnosis in literature are based on diagnosing pulse waveforms on supine posture. However, today's pulse waveforms are measured on various postures for the convenience of patients or doctors. For objective measurement, the effect of posture on the pulse waveforms should be considered. The objective of this study was to find posture-related changes in the radial pulse waveforms. Methods : We used an instrument, DMP-3000(DAEYOMEDI Co., Ansan, Korea), measuring radial pulse waveforms noninvasively by tonometric method. 25 male subjects participated in the trial. Before measuring radial pulse waveforms subjects had rest for 5 min. The pulse waveforms were measured on the left wrist. Each subject underwent this course on the supine, sitting, and standing posture. We analyzed pulse waveforms with Height-parameters, Time-parameters, Energy, and Elastic rate. Results : Height-parameters(h1~h5) on the supine posture were bigger than those on the sitting and standing posture. In case of Time-parameters, the parameters making up systolic time decrease in order of on standing, sitting, and supine position. However, systolic time and diastolic time didn't have any changes. Energy of pulse was the biggest on supine posture and Elastic rate on standing posture. Conclusions : In this study we found that posture changes affect radial pulse waveforms. For quantification of the changes, more trials should be done. After analyzing much data we might apply parameters of pulse waveforms changed by posture. Also, we might diagnose special disease with properties of pulse waveforms by posture.

  • PDF

An Experimental Study on the Measurement of Radial Directional Natural Frequency in a Passenger Car Tire Roboting under the Load (하중을 받고 회전하는 승용차 타이어의 반경방향 고규진동수 측정에 관한 실험적 연구)

  • Kim, Byoung-Sam;Hong, Dong-Pyo;Chi, Chang-Heon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.1
    • /
    • pp.1-13
    • /
    • 1996
  • The measurement of radial directional natural frequency ina passenger car tire rotating under the load is studied. In order to obtain theoretical matural frequency and mode shape, the ploane vibration of a tire is modeled to that of circular beam. By esing the Tieking method based on Hamiltons's principle, theoretical results are determined by considering tension horce due to tire inflation pressure, retational velocity and tangential, radial stiffness. Radial directional modal parameters varying with the inflation pressure, load, rotational velocity are experimentally determined by using frequency response function method. The results show that experimental conditions canbe considered as the parameters which shift the natural frequency.

On-line Estimation of Radial Immersion Ratio in Face Milling Using Cutting Force (정면 밀링에서 절삭력을 이용한 반경 방향 절입비의 실시간 추정)

  • Hwang, Ji-Hong;O, Yeong-Tak;Gwon, Won-Tae;Ju, Jong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.8
    • /
    • pp.178-185
    • /
    • 1999
  • In tool condition monitoring systems, parameters should be set to a certain threshold. In many cases, however, the threshold is dependent on cutting conditions, especially the radial immersion ratio. In this presented is a method of on-line estimation of the radial immersion ratio in face milling. When a tooth finishes sweeping, a sudden drop of cutting force occurs. The force drop is equal to the cutting force that acting on a tooth at the swept angle of cut and can be acquired from cutting force signals in feed and cross-feed directions. Average cutting force per tooth period can also be calculated from cutting force signals in two directions. The ratio to cutting forces in two directions acting on a tooth at a certain swept angle of cut and the ratio of average cutting forces in two directions per tooth period are functions of the swept angle of cut and the ratio of radial to tangential cutting forces. Using these parameters, the radial immersion ratio is estimated. Various experiments are performed to verify the proposed method. The results show that the radial immersion ratio can be estimated by this method regardless of other cutting conditions.

  • PDF

Implementation of Radial Pulse Diagnosis System using Inyoung-Cheongu Comparison Method (인영.촌구 대비법을 이용한 맥 진단 시스템 구현)

  • Lee, Ho-Jae;Park, Young-Bae;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.73-80
    • /
    • 1993
  • This paper describes the implementation of a computerized radial pulse diagnosis by Elds of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diag nosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed It. Then, we have got the characteristic parameters of radial pulse wave and also quantified thats according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial Pulse diagnosis system and then we confirmed the PossibiliLy for realization of automatic radial Pulse diagnosis in korean traditional medicine.

  • PDF

Immobilization of Heparin onto the Polyurethane

  • Cho, Chong-Su;Kim, Sung-Wan
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.147-150
    • /
    • 1986
  • This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine.

  • PDF

Sa-Am Acupuncture with Spleen Seung-gyuck induces an acute increase of radial pulse parameters related to arterial stiffness in healthy subjects: A comparative study of Jung-gyuck and Seung-gyuck

  • Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.35 no.2
    • /
    • pp.19-27
    • /
    • 2014
  • Objectives: To investigate the different effects of Sa-Am acupuncture with Spleen Jung-gyuck and Spleen Seung-gyuck on the radial pulse in healthy subjects. Methods: Sixty healthy volunteers (30 males and 30 females) participated in this study. The participants were randomly divided into three groups: control (C), Sa-Am acupuncture with Spleen Jung-gyuck (SP+) and Sa-Am acupuncture with Spleen Seung-gyuck (SP-). The radial pulse was measured using a multi-step tonometry system before, and 0, 30 and 60 minutes after acupuncture. Results: The heart rate adjusted radial augmentation index (RAI/HR) and high-tensioned pulse area (W area) significantly increased in the SP- group compared to the C and SP+ groups in males. The systolic pulse period (T4) increased significantly in the SP- group compared to the C and SP+ groups in females. The RAI/HR had positive correlations with W area and T4. Conclusion: The effects of Sa-Am acupuncture with Spleen Jung-gyuck and Spleen Seung-gyuck are different. Sa-Am acupuncture with Spleen Seung-gyuck induces acute increases of radial pulse parameters related to arterial stiffness in healthy subjects.

A Novel Approach for Well-Test Analysis of Volatile Oil Reservoirs in Two-Phase Flow Conditions

  • Baniasadi, Hamid;Rashidi, Fariborz
    • Korean Chemical Engineering Research
    • /
    • v.57 no.6
    • /
    • pp.883-890
    • /
    • 2019
  • Two-phase flow near the wellbore in volatile oil reservoirs causes complications in well test analysis. In this study, the flow behavior of volatile oil reservoirs below the bubble-point pressure and the potential of radial composite model for interpretation of two-phase well test in volatile oil reservoirs was investigated. A radial composite model was used for two-phase well test analysis. A new procedure was developed to interpret well test data and estimate the radius of the two-phase region. The changes in fluid composition near the wellbore during drawdown test were found to increase the saturation pressure, which affects the saturation profile during build-up. Well test results showed that the radial composite method is a powerful tool for well test characterization and estimation of reservoir parameters. The proposed procedure was able to estimate the reservoir parameters and radius of the two-phase region with acceptable accuracy.