• Title/Summary/Keyword: Radiographic Evaluation

Search Result 454, Processing Time 0.032 seconds

Diagnostic Radiography of Premature Closure of Distal Growth Plate of Ulna in a Dog (개에서 척골의 원위 성장판 조기 폐쇄증에 대한 방사선학적 평가)

  • 송경진;이희천;이기창;권정국;최민철
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.403-405
    • /
    • 2003
  • A 11 month-old Shihtzu was referred to the Veterinary Medical Teaching Hospital, Seoul National University. Clinical signs of this patient were lameness, shortening limb, angular deformity, rotation of foot, subluxaion of elbow joint and restricted range of movement of left forelimb. For the evaluation of the abnormalities of left forelimb, radiographic examination was carried out. Radiographic findings were characteristics of premature closure of distal ulna such as closure of distal ulna growth plate and cranial bowing of radius. With radiographic signs and physical examination, it was diagnosed as premature closure of growth plate of the left forelimb. After osteotomy of the radius and ostectomy of the ulna, radiographic evaluation of limb about angulation of elbow joint was performed every 2-3 weeks for 3 months. In case of premature closure of distal growth plate of ulna, radiography was very useful for diagnositic method of premature closure of distal ulna and monitoring of healing process.

Automatic Exposure Control Performance Evaluation of Digital Radiographic Imaging System by Manufacturer Using Coins (동전을 이용한 제조사 별 디지털 방사선 영상 시스템의 자동노출제어 성능 평가)

  • Lim, Se-Hun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, we proposed an image quality control for an automatic exposure control (AEC) of digital radiographic imaging system and tried to analyze the performance of the AEC by various manufacturer. The subjects of the experiment were analyzed for the AEC image quality evaluation using digital radiation generators from four manufacturer such as PHILIPS, GE Healthcare, SAMSUNG Healthcare, DK Medical Solution. We used as materials for the implementation of the image quality evaluation by coins (500 won, KOMSCO, Korea). This study evaluated the performance evaluation of the AEC as image quality and exposure dose (Milliampere-seconds; mAs). The image quality evaluation was tried visual assessment by two radiologic technologists and contrast to noise (CNR) by ImageJ. The exposure dose investigated mAs on digital radiation generators. The radiographic coin images acquired 360 images based on change in the control factors of the AEC, which were kVp, the consistency of field configuration and dominant zone, sensitivity and density. As a result, there was a significant difference in the AEC performance between manufacturer. The CNR by the AEC for each manufacturer showed a difference of up to about 1.9 times. The exposed tube current by the AEC for each manufacturer showed a difference of up to about 5.8 times. It is expected that our proposed evaluation method using coins could be applied as the AEC performance evaluation method in the future.

Usefulness of the Oblique Radiographic View in Ankle Fractures (족근 관절 골절에서 사면상 단순 방사선 사진의 유용성)

  • Cho, Duck-Yun;Song, Sang-Jun;Yoon, Hyung-Ku;Han, Soo-Hong;Chang, Ji-Hoon;Yoon, Byung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.94-98
    • /
    • 2005
  • Purpose: To compare the radiographic evaluations between two radiographic views (AP and lateral views) and four radiographic views (AP, lateral and both oblique views) in ankle fractures. Materials and Methods: From January 2000 to June 2002, 60 cases of ankle fractures were treated with open reduction and internal fixation and its followed up periods were at least 2 years. All cases were classified into three groups according to the method of preoperative radiographic evaluation. Two radiographic views (AP and lateral views) were taken in group A and four radiographic views (AP, lateral and both oblique views) were taken in group B. 12 Cases were evaluated with three dimensional computed tomography (3D CT). Four radiographic views and 3D CT were taken in group C. All cases were classified according to the Danis-Weber and Lauge-Hansen classification. Displacement of fracture fragment of medial, lateral, posterior malleolus and size of fracture fragment of posterior malleous were measured using picture archiving communication system (PACS). Results: Although kappa value between two or four radiographic views were good or excellent in Danis-Weber classification and Lauge-Hansen classification of ankle fractures, the displacements of medial and lateral malleoli were statistically different. Four radiographic views evalulated the degree of displacement of medial and lateral fragments more accurately compared to two radiographic views. Conclusion: Four radiographic views will be more useful than two radiographic views to decide the method of treatment and operation considering the displacement of fracture fragment.

  • PDF

A Study on the Status and Improvement Direction of Radiographic Imaging Examination Assessment in Korea Medical Institutions (한국 의료기관의 방사선 영상검사 평가 현황 및 과제)

  • Young-Kwon Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.565-572
    • /
    • 2023
  • This study was conducted to analyze the status radiological imaging examinations assessment in Korea medical institutions conducted in the public sector and suggest a direction for improvement. Among the assessment of medical institutions, the main assessment related to radiographic imaging examinations are the certification evaluation of medical institutions and the adequacy assessment of radiographic imaging examinations. The certification evaluation of medical institutions evaluates the image inspection operation process, provision of accurate results, and compliance with safety management procedures. In the assessment of adequacy of radiographic imaging examinations, structural indicators related to manpower and equipment, patient evaluation implementation rate, and exposure reduction programs were included. However, for safer and higher-quality radiological imaging examinations, it is necessary to increase the participation rate of medical institutions in certification evaluations. In addition, it is necessary to improve the manpower indicator, and incentive payments can be considered to induce quality improvement of medical institutions in the future. Integrated management of radiation exposure at the national level should also be carried out simultaneously.

Evaluation of dental panoramic radiographic findings in edentulous jaws: A retrospective study of 743 patients "Radiographic features in edentulous jaws"

  • Kose, Taha Emre;Demirtas, Nihat;Karabas, Hulya Cakir;Ozcan, Ilknur
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.380-385
    • /
    • 2015
  • PURPOSE. The aim of this study was to determine the frequency of significant panoramic radiographic findings and eventual treatment requirements before conventional or implant supported prosthetic treatment in asymptomatic edentulous patients. MATERIALS AND METHODS. A total of 743 asymptomatic edentulous patients were retrospectively evaluated using a digital panoramic system. We analyzed the radiographic findings, including impacted teeth, retained root fragments, foreign bodies, severe atrophy of the posterior maxillary alveolar bone, mucous retention cysts, soft tissue calcifications and radiopaque-radiolucent conditions. RESULTS. Four-hundred-eighty-seven (65.6%) patients had no radiographic finding. A total of 331 radiographic findings were detected in 256 (34%) patients. In 52.9% (n=175) of these conditions, surgical treatment was required before application of implant-supported fixed prosthesis. However, before application of conventional removable prosthesis surgical treatment was required for 6% (n=20) of these conditions. CONCLUSION. The edentulous patients who will have implant placement for implant-supported fixed prosthesis can frequently require additional surgical procedures to eliminate pathological conditions.

The influence of smoking on the outcome of surgical periodontal therapy -2-year retrospective study (흡연이 치주수술을 포함한 치주치료의 결과에 미치는 영향)

  • Chang, Mun-Taek;Yoon, Joung-Sik;Choi, Seoung-Hwan;Seo, Sung-Chan
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.395-405
    • /
    • 2003
  • The purpose of this study was to examine the effect of smoking on the clinical, radiographic outcome of surgical peridontal therapy. The outcome of periodontal surgery was evaluated in 51 systemically healthy subjects that had received maintenance care. The study subject consisted of 26 smokers and 25 non-smokers. The average age of smoking patients was 51 years old and non-smoking patients was 48 years old. Changes of probing pocket depth(PPD) and radiographic bone height, and number of missing teeth compared between smokers and non-smokers during maintenance period after surgical therapy. The clinical parameters were less favorable in the smoking group compared with non-smoking group. The number and percentage of missing teeth were greater in smokers(21.6%) than non-smokers(l2.4%), especially in molars. The mean presurgery PPD was similar in smokers and non-smokers, molars and premolars, but significantly decreased at least 2 years after surgery. The mean PPD reduction was significantly greater in non-smokers than smokers. Both in the smoking and non-smoking group, the mean PPD reduction was significantly greater in premolars than molars. The radiographical evaluation was also less favorable in the smoking group than non-smoking group. The radiographic evaluation of bone height in smokers showed bone loss. On the contrary, bone height of non-smokers showed bone gain during the period of maintenance. But there was no significant difference between molars and premolars. The clinical and radiographic outcomes of the smoking group was less favorable than those of the non-smoking group. Therefore , smoking seems to influence on the clinical and radiographic outcomes of surgical periodontal therapy.

Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

  • Dantas, Raquel Venancio Fernandes;Sarmento, Hugo Ramalho;Duarte, Rosangela Marques;Meireles Monte Raso, Sonia Saeger;de Andrade, Ana Karina Maciel;Dos Anjos-Pontual, Maria Luiza
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Materials and Methods: Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using #4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. Results: The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. Conclusion: The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

Long-term radiographic evaluation of infrabony defect treated by flap operation (치주판막술에 의해 치료된 골연하 결손부의 장기적 방사선학적 변화 양사의 관찰)

  • Bae, Sang-Ryul;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.429-436
    • /
    • 2008
  • Purpose: The goal of periodontal regenerative therapy is to replace bone, cementum, and periodontal ligament on a previously diseased root surface, which has suffered the loss of these supporting structures. To accomplish the regeneration, a number of surgical procedures have been advocated throughout the years. There seems to be a potential for some spontaneous periodontal tissue regeneration in the bottom of periodontal defect following open flap debridement alone. The aim of this study was to analyse the radiographic bone changes over 2-year after flap operation. Material and Methods: Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients had clinical and radiographic evidence of infrabony defect(s). forty two sites of 33 patients aged 26 to 65 (mean age 45.5) were treated by flap operation with or without osseous surgery. Baseline and over 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, gender, defect depth, defect angle) using the paired t-test were examined. Result: We observed 0.74 mm of bone fill, 0.66 mm of crestal resorption, 1.40 mm of defect resolution, and 27% of percentage of defect resolution. Mandible, women, deeper initial defect depth, narrower initial defect angle showed greater bone fill, defect resolution, and % of defect resolution. Conclusion: The results of this study suggest that the use of flap operation did enhance the outcome in terms of radiographically detectable bone fill. Both treatment resulted in some loss of crestal bone height.

Radiographic evaluation of infra-bony defects treated by bone graft procedures (골 이식술에 의해 치료된 골연하 결손부의 방사선학적 변화 양상의 관찰)

  • Ryu, Sang-Ho;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.437-444
    • /
    • 2008
  • Purpose: A number of techniques and materials have been used for periodontal regeneration and bone graft procedures with guided tissue regeneration(GTR) have been suggested as alternatives to osseous surgery in the management of local infra-bony defects. However, the long-term stability and treatment outcome following bone graft procedure of infra-bony defects is poorly documented. The purpose of this study was to assess radiographic change in infra-bony defects over 2 years after bone graft procedures with various graft materials. Material and Methods: Patients attending the department of periodontics of Kyungpook National University Hospital were studied. Patients showed clinical and radiographic evidence of infra-bony defect(s). 44 sites of 34 patients aged 31 to 69 (mean age 48.3) were treated by bone graft procedure with a bone graft material. Baseline and 2-year follow-up radiographs were collected and evaluated for this study. Radiographic assessment includes a bone fill, bone crest change, defect resolution, and % of defect resolution. Pre- and post-treatment differences between variables (maxilla and mandible, defect depth, defect angle, bone graft materials) using the paired t-test were examined. Result: We observed $1.15{\pm}1.95\;mm$ of bone fill, $0.40{\pm}1.19\;mm$ of crestal resorption, $1.55{\pm}1.77\;mm$ of defect resolution, and $40{\pm}44%$ of percentage of defect resolution. Deeper initial defect depth, narrower initial defect angle showed significantly greater bone fill, defect resolution, and % of defect resolution. But no significant difference was observed in graft sites and graft materials. Conclusion: If good oral hygiene maintenance and periodic recall check of patients is assured, bone graft procedure using various graft materials is one of the appropriate treatment modality for regenerative therapy of infra-bony defects.

Radiographic Evaluation of Vertebral Heart Scale and Caudal Vena Cava Size Useful for Diagnosing Cardiac Diseases in Endangered Long-Tailed Goral (Naemorhedus caudatus)

  • Sangjin Ahn;Woojin Shin;Yujin Han;Sohwon Bae;Chea-Un Cho;Sooyoung Choi;Jong-Taek Kim
    • Journal of Veterinary Clinics
    • /
    • v.40 no.2
    • /
    • pp.119-123
    • /
    • 2023
  • Although various imaging evaluation methods have been developed and utilized, thoracic radiography remains essential and is the top priority for diagnosing and managing cardiac diseases. Thoracic radiographic measurements associated with the vertebral heart scale (VHS) and caudal vena cava (CVC) can objectively diagnose cardiac disease in many animals. In particular, VHS measurement is primarily used to evaluate the dimensions of the heart size on thoracic radiographs and can measure cardiomegaly more objectively. Additionally, the value of the CVC compared with the aorta (Ao) and the length of vertebrae (VL) can be used as valuable parameters in right congestive heart failure. To describe the CVC/Ao and CVC/VL ratios in 10 long-tailed gorals (Naemorhedus caudatus) without subjective radiographic evidence of cardiac diseases. The VHS, CVC, Ao, and VL of gorals were measured in the right lateral (RL) view of the thoracic radiographs. In the RL view of 10 gorals, the VHS was 9.31 ± 0.55 vertebrae (v), the CVC/Ao ratio was 0.84 ± 0.13, and the CVC/VL ratio was 0.67 ± 0.09. Additionally, the thoracic morphology of gorals was determined to be intermediate (thoracic depth-to-width ratio, 1.04 ± 0.09, 0.75-1.25). This study confirmed that VHS was significantly correlated with CVC and Ao, and measuring and comparing each value would help diagnose cardiac diseases in gorals. The radiographic measurements in this study will allow veterinarians to diagnose several cardiac diseases in gorals.