A Running Stability Test of 1/5 Scaled Bogie Using Small Scale Derailment Simulator (소형탈선시뮬레이터를 이용한 1/5 축소대차의 주행안정성 시험)

  • Eom, Beom-Gyu;Lee, Se-Yong;Lee, Young-Yeob;Kang, Bu-Byoung;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2600-2608
    • /
    • 2011
  • The dynamic stability of railway vehicle has been one of the important issues in railway safety. The dynamic simulator has been used in the study about the dynamic stability of railway vehicle and wheel/rail interface. Especially, a small scale simulator has been widely used in the fundamental study in the laboratory instead of full scale roller rig which is not cost effective and inconvenient to achieve diverse design parameters. But the technique for the design of the small scale simulator for the fundamental study about the dynamic characteristics of the wheel-rail system and the bogie system has not been well developed in Korea. Therefore, the research about the development of the small scale simulator and the bogie has been conducted. As this paper, To predict the dynamic behavior of railway vehicle, we studied running stability test of 1/5 scaled bogie that similarity laws is applied using small scale derailment simulator. For the operation of the small scale derailment simulator, it is required to investigate the performance and characteristics of the system. This could be achieved by a comparative study between an analysis and an experiment. This paper presented the analytical model which could be used for verifying of the test results and understanding of the physical behavior of the dynamic system comprising the small scale bogie and the simulator.

  • PDF

Noise and Vibration Solutions Considering Stability Effects for High-Speed Rail ChonAn Station in Korea (한국고속철도 천안역사에 대한 소음 및 진동영향 연구)

  • Kweon Young-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.848-853
    • /
    • 2005
  • The objective of this paper is to address to the providing an adequate noise and vibration solution, required for High Speed Rail while maintaining the stability criteria of the ChonAn station structure, the first constructed in Korean High Speed Railway. The significant acoustic pressure level will be induced by the high speed trains passing-by. Therefore, the high level study of this case is necessary. The acoustic pressure level of 85 dB(A) inside the ChonAn station is expected, and the spaces below concrete slab are not suitable for commercial purpose, thus installation of filtering systems (spring boxes containing viscous dampers, ballast mats and acoustic shield) are provided to reduce the effect of the noise and vibration to acceptable level of 55 dB(A). But, a major drawback of application of the previously conducted experimental results was that the actual effect of installation of filtering system was never been validated. Therefore, the acquisition of noise and vibration on the present structure were obtained and compared to the computer simulations. These predicted the behavior of the station reasonably well. Also, the installation of filtering systems gave the superior reduction on noise and vibration. This application is successfully adapted without scarifying stability criteria related to the structural stability including excessive deformations or displacements. Three traffic operation safety limits: deck vertical acceleration, deflection of the structure, and longitudinal displacement of the slab were satisfactory.

  • PDF

Sensitivity of the ballast resistance and track irregularity on the track stability (궤도 안정성에 대한 도상저항력과 궤도틀림의 민감도)

  • Lim, Nam Hyoung;Choi, Sang Hyun;Lee, Chin Ok;Sung, Ik Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.519-526
    • /
    • 2005
  • During summer, very high compressive force occurs on the continuous welded rail (CWR) track because of the increase of rail temperature (max. $60^{\circ}C$). This extreme temperature stress can cause the CWR track to buckle. Among many CWR parameters affecting the track buckling, the influence of the lateral and longitudinal ballast resistance was investigated on the stability of the CWR track in this study. Also, the sensitivity of the track irregularity such as the alignment defect and the gauge irregularity was investigated.

Management Plan of Light Rail Transit System (경량전철 시스템 시험선 운영 방안)

  • Lee, H.M.;Lee, A.H.;Han, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1657-1659
    • /
    • 2005
  • Test track of the Light Rail Transit(LRT system was developed and organically combined with technologies of power supply system, signal communication system and track structure The purpose of the test track is a acquiring of reliability and stability through a sufficient performance test Therefore, this paper draws up ail management plans for tests of the LRT system

  • PDF

Critical speed analysis of the High-Speed EMU (분산형 고속전철의 임계속도 해석)

  • Shin, Bum-Sik;Lee, Seung-Il;Lee, Sang-Won;Koo, Ja-Choon;Choi, Yeon-Sun
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.973-978
    • /
    • 2008
  • This study concerned on the critical speed due to hunting and snake motion train to ensure the stability. First, the critical speed was calculated by using a numerical model, and calculated the critical speed of the vehicle through the simulation with the use of ADAMS/RAII. Also, the snake motion was confirmed through a modal analysis and running simulation. The calculated results, show that the rail irregularity becomes the influential factors of the stability since it is the direct source of excitation of the vehicle.

  • PDF

The Improvement of Control Performance for a Magnetic Levitation System (자기부상 시스템의 성능개선)

  • Kim, Jong-Moon;Kang, Do-Hyun;Park, Min-Kook
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.864-866
    • /
    • 2003
  • In this paper, the improvement of control performance for a magnetic levitation system is presented. The model of a single-magnet system with rail is derived. As a conventional controller, PID controller is designed and implemented. This controller has a narrow stability margin due to low-order controller structure so that it cause unstability for a flexible rail. So to improve the control performance and stability margin, a robust controller as a new controller is designed and implemented using a VME-based digital controller. As a result, the controller performance of the new designed controller is better than that of the conventional controller.

  • PDF

Effect of the support pressure modes on face stability during shield tunneling

  • Dalong Jin;Yinzun Yang;Rui Zhang;Dajun Yuan;Kang Zhang
    • Geomechanics and Engineering
    • /
    • v.36 no.5
    • /
    • pp.417-426
    • /
    • 2024
  • Shield tunneling method is widely used to build tunnels in complex geological environment. Stability control of tunnel face is the key to the safety of projects. To improve the excavation efficiency or perform equipment maintenance, the excavation chamber sometimes is not fully filled with support medium, which can reduce the load and increase tunneling speed while easily lead to ground collapse. Due to the high risk of the face failure under non-fully support mode, the tunnel face stability should be carefully evaluated. Whether compressive air is required for compensation and how much air pressure should be provided need to be determined accurately. Based on the upper bound theorem of limit analysis, a non-fully support rotational failure model is developed in this study. The failure mechanism of the model is verified by numerical simulation. It shows that increasing the density of supporting medium could significantly improve the stability of tunnel face while the increase of tunnel diameter would be unfavorable for the face stability. The critical support ratio is used to evaluate the face failure under the nonfully support mode, which could be an important index to determine whether the specific unsupported height could be allowed during shield tunneling. To avoid of face failure under the non-fully support mode, several charts are provided for the assessment of compressed air pressure, which could help engineers to determine the required air pressure for face stability.

The Development of Rail-Transport Operation Control based on Unsaturated Soil Mechanics Concept (불포화토이론을 이용한 강우시 열차운전규제기준 개발)

  • Kim, Hyun-Ki;Shin, Min-Ho;Kim, Soo-Sam
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.1 s.12
    • /
    • pp.25-31
    • /
    • 2004
  • Infiltration of rainfall causes railway embankment to be unstable and may result in failure. Basic relationship between the rainfall and stability of railway embankment is defined to analyze the stability of embankment by rainfall. An experimental study for defining of infiltration rate of rainfall into slope is conducted in the lab. The results of Rainfall Infiltration show that rainfall Infiltration is not equal to infiltration as like reservoir because rate of rainfall infiltration is controlled by slope angle. Based on these results, boundary condition of rainfall is altered and various numerical analysis are performed. The variation of shear strength, the degree of saturation and pore-water pressure for railway slope during rainfall can be predicted and the safety factor of railway slope can be expressed as the function of rainfall amount, namely rainfall index. Therefore, it is judged that this rainfall index can be a good tool for the rail-transport operation control.

Dynamic Analysis for Improvement of Running Stability of Rubber Tired AGT Localization Bogie (고무차륜 경량전철 국산화 대차의 주행안정성 향상을 위한 동특성 해석)

  • Eom, Beom-Gyu;Lee, Hi-Sung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.4
    • /
    • pp.307-317
    • /
    • 2012
  • The LRT(light rail transit) system, which has medium transport capacity between subway and bus is an advanced transportation system. It has many benefits like chap construction and operational cost down through driverless and flexible route planning. The rubber tired AGT(K-AGT) is a kind of LRT, which has rubber wheels and side guides. The side guides has many advantages, but brings vibration and noise problems from the friction between the guide rail and the wheels. This is the major source for the of passengers' discomfort. The purpose of this paper is to analyze dynamic characteries and running stability of the rubber tired AGT localization bogie if the AGT's speed is increased from 70 km/h to 80 km/h. The current design parameters of bogie suspension, as it is designed, was examined to satisfy the comfort index of the railway vehicle in performance test.

Air-gap Signal Treatment at rail-joint in Maglev System (자기부상시스템에서 레일 이음매 통과시 공극 처리방법)

  • Sung, H.K.;Jho, J.M.;Lee, J.M.;Bae, D.K.;Kim, B.S.;Kim, D.S.;Shin, B.C.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.310-312
    • /
    • 2006
  • Maglev using EMS becomes unstable by unexpected big air-gap disturbance. The main causes of the unexpected air-gap disturbance are step-wise rail joint and large distance between rail splices. For the stable operation of the Maglev, the conventional system uses the threshold method, which selects one gap sensor among two gap sensors installed on the magnet to read the gap between magnet and guide rail. But the threshold method with a wide bandwidth makes the discontinuous air-gap signal at the rail joints because of the offset in air gap sensors and/or the step-wise rail joins. Further more, in the case of the one with a narrow bend-width, it makes Maglev system unstable because of frequent alternation. In this paper, a new method using fuzzy rule to reduce air-gap disturbances proposed to improve the stability of Maglev system. It treats the air-gap signal from dual gap sensors effectively to make continuous signal without air gap disturbance. Simulation and experiment results proved that the proposed scheme was effective to reduce air-gap disturbance from dual gap sensors in rail joints.

  • PDF