• Title/Summary/Keyword: Rapid inflection point method

Search Result 4, Processing Time 0.018 seconds

Rapid Inflection Point Method of Consolidation Testing (변곡점을 이용한 신속한 압밀시험에 관한 연구)

  • 민덕기;황광모;최규환
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.681-688
    • /
    • 2000
  • This study presented the new method for evaluating the coefficient of consolidation by using inflection point method which was based on the fact that time factor, T corresponding to the inflection point of a semilogarithmic plot of a time curve is fixed and equals to T = 0.405 at 70% consolidation. In the proposed method, the next load increment is applied as soon as the necessary time required to identify the inflection point. Thus, the coefficient of consolidation may be easily evaluated. The time required to complete the testing using this rapid consolidation method could be as low as 1.5-3 hours compared with 1 or 2 weeks in the case of the conventional consolidation test.

  • PDF

Rapid Consolidation Test Using Inflection Point Method (변곡점법에 의한 신속 압밀시험)

  • 민덕기;황광모;최규환
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.4
    • /
    • pp.85-93
    • /
    • 2002
  • This study presented a new method for evaluating the coefficient of consolidation by using inflection point method which was based on the fact that time factor, T corresponding to the inflection point of a semi-logarithmic plot of a time curve is fixed and equals to T = 0.405 at 70.03% consolidation. In the proposed method, as the next load increment is applied as soon as the inflection point is confirmed, the time required to identify the inflection point can be shortened. Thus, the coefficient of consolidation may be easily evaluated. The time required to complete the testing using this rapid consolidation method could be as low as 0.5~9 hours compared with 1 or 2 weeks in the case of the conventional consolidation test. For this study, we designed settlement equipment for normalization of test samples. In test results, the factors of consolidation agreed with undisturbed samples results.

Compressibility Characteristics of the Lime Treated Clay (생석회 혼합토의 압축특성에 관한 연구)

  • 민덕기;황광모;오미희
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.23-29
    • /
    • 2003
  • In this paper, effects of the acidification of ground and the chemical additive materials-ferric oxide, calcium chloride and calcium sulphate on the compressibility characteristics of the marine clay treated with quick lime were investigated. The rapid inflection point method was carried out. Results showed that the compression index of the untreated marine clay increased as the pH of pore water decreased. Also, the preconsolidation pressure, the coefficient of consolidation and the coefficient of permeability of the untreated marine clay decreased with pH of pore water. In the case of the marine clay treated with the quick lime-calcium chloride, the compression index decreased and the coefficient of consolidation and the coefficient of permeability increased. Specially, the preconsolidation pressure of sample treated with the quick lime-ferric oxide was higher than that of another samples.

Factors Affecting Microbial Respiration (MR) by Rapid Oxygen Uptake Rate (OUR) Monitoring (급속 OUR 모니터링을 이용한 Microbial Respiration (MR) 영향인자 평가)

  • Park, Se-Yong;Mo, Kyung;Kim, Youn-Kwon;Kim, Moon-Il
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.630-635
    • /
    • 2011
  • As this study was estimation of factors of rapid OUR (Oxygen Uptake Rate) monitoring method. Experiment for estimating factors of optimal microorganism activity was carried out in this study. In addition to comparison and estimation of SCOD variation by OUR variation using real wastewaters. In consequence OUR value was highest when F/M ratio, pH and temperature were 0.03~0.05, 6.0~8.5 and $20{\sim}30^{\circ}C$ respectively. Oxygen consumption by nitrification was incomplete. OUR variation of SCOD was recognizable difference of degradable rate at before and after of inflection point OUR. This study used an experimental method for real time prediction of the influent of the sewage treatment plant for optimal operation is expected to be able to do.