• Title/Summary/Keyword: Reactivation

Search Result 231, Processing Time 0.065 seconds

Effect of Reactivation of Activated Carbon on Adsorption of Natural Organic Matter (활성탄 재생이 자연유기물질의 흡착에 미치는 영향)

  • Hong, Seongho;Choi, Jusol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.3
    • /
    • pp.323-329
    • /
    • 2007
  • There is no certain definition about advanced drinking water treatment but it is generally known as activated carbon process, membrane process or ozone process which can remove non-conventional pollutants such as taste and odor compounds, and micro-pollutants. There are more than 20 processes related to activated carbon as adsorber or biological activated carbon in Korea. The saturated carbon by pollutants can be reused by reactivation. However, the effect of reactivation on activated carbon is not well-understood in terms of changing physical properties of carbon to adsorption capacity of natural organic matter (NOM). In this study, the effects of reactivation on physical properties of activated carbon were investigated by isotherm and breakthrough of NOM. Ash content was increased from 8% to 13.3%. Iodine number is commonly used as an indicator for performance of reactivation. The iodine number was decreased about 20% after reactivating twice. The degree of reactivation can be evaluated by not only iodine number but also apparent density.

Thermostability and Reactivation of Peroxidase from Soybean Sprouts (콩나물 Peroxidase의 열안정성과 재활성화)

  • 박인식;이민경;길지은
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.1
    • /
    • pp.81-86
    • /
    • 1999
  • The factors affecting thermostability and reactivation of peroxidase from soybean sprouts(Glycine max L.) were investigated. The enzyme was the most stable at pH 7.0 and below 60oC. Thermostability of the enzyme was reduced by addition of sodium chloride and saccharides. The partially inactivated enzyme by heat treatment at 75oC for 10 min was reactivated up to 211.5% at the optimal reactivation condition. The optimal pH and temperature for reactivation of the enzyme were pH 9.0 and 40oC, respectively. The reactivation was completely inhibited by addition of sulfhydryl reagent such as L cysteine.

  • PDF

Factors Affecting Thermal Inactivation and Reactivation of Korean-Radish Peroxidase (한국산 무 Peroxidase의 열변성 및 재활성화에 미치는 요인)

  • 이경아;홍정민;김기남;박인식
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.19 no.4
    • /
    • pp.301-304
    • /
    • 1990
  • Factors affecting thermal inactivation and reactivation of korean radish peroxidase were inves-tigated,. The enzyme was stable below pH4.0 and above pH 8.0 The thermostablity of the enzyme was increased by addition of glucose sodium chloride and albuminl The inactivated enzyme by heat treatment was reactivated at room temperaturem The optimal pH for reactivation of the enzyme was pH of 9.0 The reactivation rate of the enyme was not afected by addition of glucose sodium chloride and albumin, The reactivation was completely inhibited by addition of sulfhydryl reagent such as dithiothreitol.

  • PDF

Fault reactivation potential during $CO_2$ injection in the Gippsland Basin, Australia (호주 Gippsland Basin에서 $CO_2$ 주입 중 단층 재활성화의 가능성)

  • Ruth, Peter J. van;Nelson, Emma J.;Hillis, Richard R.
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.50-59
    • /
    • 2006
  • The risk of fault reactivation in the Gippsland Basin was calculated using the FAST (Fault Analysis Seal Technology) technique, which determines fault reactivation risk by estimating the increase in pore pressure required to cause reactivation within the present-day stress field. The stress regime in the Gippsland Basin is on the boundary between strike-slip and reverse faulting: maximum horizontal stress $({\sim}\;40.5\;Mpa/km)$ > vertical stress (21 Mpa/km) ${\sim}$ minimum horizontal stress (20 MPa/km). Pore pressure is hydrostatic above the Campanian Volcanics of the Golden Beach Subgroup. The NW-SE maximum horizontal stress orientation $(139^{\circ}N)$ determined herein is broadly consistent with previous estimates, and verifies a NW-SE maximum horizontal stress orientation in the Gippsland Basin. Fault reactivation risk in the Gippsland Basin was calculated using two fault strength scenarios; cohesionless faults $(C=0;{\mu}=0.65)$ and healed faults $(C=5.4;\;{\mu}=0.78)$. The orientations of faults with relatively high and relatively low reactivation potential are almost identical for healed and cohesionless fault strength scenarios. High-angle faults striking NE-SW are unlikely to reactivate in the current stress regime. High-angle faults oriented SSE-NNW and ENE-WSW have the highest fault reactivation risk. Additionally, low-angle faults (thrust faults) striking NE-SW have a relatively high risk of reactivation. The highest reactivation risk for optimally oriented faults corresponds to an estimated pore pressure increase (Delta-P) of 3.8 MPa $({\sim}548\;psi)$ for cohesionless faults and 15.6 MPa $({\sim}2262\;psi)$ for healed faults. The absolute values of pore pressure increase obtained from fault reactivation analysis presented in this paper are subject to large errors because of uncertainties in the geomechanical model (in situ stress and rock strength data). In particular, the maximum horizontal stress magnitude and fault strength data are poorly constrained. Therefore, fault reactivation analysis cannot be used to directly measure the maximum allowable pore pressure increase within a reservoir. We argue that fault reactivation analysis of this type can only be used for assessing the relative risk of fault reactivation and not to determine the maximum allowable pore pressure increase a fault can withstand prior to reactivation.

Tuberculous Pleurisy : Clinical Characteristics of Primary and Reactivation Disease (결핵성 흉막염에서 초감염 결핵과 재발성 결핵의 임상 양상)

  • Hong, Koo Hyun;Lim, Sang Soo;Shin, Jae Min;Park, Jae Seuk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.6
    • /
    • pp.526-532
    • /
    • 2006
  • Backgroud: Traditionally, tuberculous pleurisy has been known to largely develop as primary tuberculosis. However, as the incidence of tuberculosis decrease, recent studies have shown reactivation tuberculosis has become the main cause of tuberculous pleurisy. Methods: 141 cases of tuberculous pleurisy, between January 2003 and February 2006, at the Dankook university hospital. were retrospectively studied. The patients were divided into primary and reactivation tuberculosis. based on the history and radiological characteristics, and the clinical, radiological characteristics at the time of diagnosis and residual pleural thickening after 6 month of chemotherapy were compared between the two groups. Results: 1. Of the 141 tuberculous pleurisy cases, in 135 it was possible to differentiate between primary and reactivation tuberculosis. 2. Of the 135 tuberculous pleurisy cases, 38 (28%) showed a primary tuberculosis pattern, and 98 (72%) showed a reactivation tuberculosis pattern. 3. There were no significant differences between primary and reactivation tuberculosis in relation to age, sex, duration of symptom, amount of pleural effusion, pleural fluid WBC, lymphocyte count, and level of protein, LDH and ADA at the time of diagnosis 4. 124 patients were followed for 6 months after diagnosis of tuberculous pleurisy, and there was no significant difference in the residual pleural thickening between primary and reactivation tuberculosis. Conclusion: In South Korea, a reactivation disease is currently a more common cause of tuberculous pleurisy than a primary disease. There was no difference in the clinical characteristics between primary and reactivation tuberculosis.

Disinfection and Reactivation of Microorganisms after UV Irradiation for Agricultural Water Reuse of Biofilter Effluent

  • Jung, Kwang-Wook;Yoon, Chun-G.;Hwang, Ha-Sun;Ham, Jong-Hwa
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.94-106
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of UV disinfection system and the reactivation of indicator microorganisms (TC, FC, E. coli) after UV irradiation for agricultural reuse of reclaimed water. Photoreactivation and dark repair enable UV-inactivated microorganisms to recover and may reduce the efficacy of UV inactivation, which might be drawbacks of the UV disinfection method. The effluent of biofilter for 16-unit apartment house was used as input to the UV disinfection system, and average SS and BOD concentration were 3.8 and 5.7 mg/L, respectively, and the mean level of total coliform was in the range of $1.0\times10^4$ MPN/100mL. UV disinfection was found to be effective and it reduced mean concentration of indicator microorganisms (total coliform, fecal coliform, and E. coli) to less than 100 MPN/100mL within 60s exposure using 17, 25, and 40W lamps. Two UV doses of 6 and 16 mW$\cdot$s/$\textrm{km}^2$ were applied and microorganisms reactivation was monitored under the dark, photoreactivating light, and solar irradiation. Microorganisms reactivation was observed in the UV dose of 6 mW$\cdot$s/$\textrm{km}^2$, and numbers increased up to 5% at the photoreactivating light and 1% at the dark. However, microorganisms were inactivated rather than reactivated at the solar radiation and numbers decreased to non-detectible level about below 2 MPN/100mL in 4 hours. In the case of 16 mW$\cdot$s/$\textrm{km}^2$, microorganism reactivation was not observed indicating that UV dose might affect the reactivation process such as photoreactivation and dark repair. Therefore, concerns associated with microorganism reactivation could be controlled by sufficient UV dose application. Agricultural reuse of reclaimed water might be even less concerned due to exposure to the solar irradiation that could further inactivate microorganisms. The pilot study result is encouraging, however, sanitary concern in water reuse is so critical that more comprehensive investigation is recommended.

Degradation Damage Evaluation for Turbine Structural Components by Electrochemical Reactivation Polarization Test (전기화학적 재활성화 분극시험에 의한 터빈부재의 열화손상 평가)

  • Kwon, Il-Hyun;Baek, Seung-Se;Lyu, Dae-Young;Yu, Hyo-Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1241-1249
    • /
    • 2002
  • The extent of materials deterioration can be evaluated accurately by mechanical test such as impact test or creep test. But it is almost impossible to extract a large test specimen from in-service components. Thus material degradation evaluation by non-destructive method is earnestly required. In this paper, the material degradation for virgin and several aged materials of a Cr-Mo-V steel, which is an candidated as structural material of the turbine casing components for electric power plant, is nondestructively evaluated by reactivation polarization testing method. And, the results obtained from the test are compared with those in small punch(SP) tests recommended as a semi-nondestructive testing method using miniaturized specimen. In contrast to the aged materials up to 1,000hrs which exhibit the degradation behaviors with increased ${\Delta}[DBTT]_{SP}$, the improvement of mechanical property can be observed on the 2,000hrs and 3,000hrs aged materials. This is because of the softening of material due to the carbide precipitation, the increase of ferritic structures and the recovery of dislocation microstructure by long-time heat treatment. The reactivation rates($I_R/I_{Crit},\;Q_R/Q_{Crit}$) calculated by reactivation current densityt ($I_R$) and charge($Q_R$) in the polarization curves exhibit a good correlation with ${\Delta}[DBTT]_{SP}$ behaviors.

An Evaluation of Aging Degradation Damage for Cr-Mo-V Steel by Electrochemical Potentiokinetic Reactivation Test (재활성화 분극시험에 의한 Cr-Mo-V강의 시효열화 손상 평가)

  • Kwon, Il-Hyun;Na, Sung-Hun;Song, Gee-Wook;Yu, Hyo-Sun
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.49-54
    • /
    • 2000
  • Cr-Mo-V steel is widely used as a material for the turbine structural component in fossil power plants. It is well known that this material shows the various material degradation phenomenons such as temper embrittlement, carbide coarsening. and softening etc. or ins to the severe operation conditions as high temperature and high pressure. These deteriorative factors cause tile change of mechanical properties as reduction of fracture toughness. Therefor it is necessary to evaluate tile extent of degradation damage for Cr-Mo-V steel in life assessment of turbine structural components. In this paper. the electrochemical potentiokinetic reactivation(EPR) test in $50wt%-Ca(NO_3)_2$ solution is performed to develop the newly technique for degradation damage evaluation of Cr-Mo-V steel. The results obtained from the EPR test are compared with those in small punch(SP) tests recommended by semi-nondestructive testing method using miniaturized specimen. The evaluation parameters used in EPR test are tile reactivation current density$(I_R)$ and charge$(Q_{RC})$ reactivation rate$(I_R/I_{Crit},\;Q_R/Q_{Crit})$. The results suggest that $I_R/I_{Crit}$ in these parameters shows a good correlation with SP test results.

  • PDF

A Restrictive Virus Tropism, Latency and Reactivation of Pseudorabies Virus Following Irreversible Deletion of Bsrl Restriction Site in the Thymidine-kinase Gene

  • Mohd Lila Mohd Azmi;Zeenathul, Nazariah-Allaudin;Abdel-Wahid Saeed Ali;Che Abdul Rahim Mohamed;Kamarudin, Awag-Isa
    • Journal of Microbiology
    • /
    • v.40 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • At the dose of 1000 p.f.u. per mouse,100% mortality occurred in mice inoculated with wild-type pseudorabies virus (PrV). In contrast, upon stable deletion of 10 bp nucleotides at the Bsrl site within the TK gene, PrV was rendered to be completely apathogenic. The deletion also caused the virus to be less capable of replicating in respiratory as well as in nervous system tissues. Although animals were exposed to high titers of TK-deleted PrVs, the virus failed to replicate to a high titer as compared to the pathogenic parental virus. In contrast to previous studies the deletion in the TK gene did not prevent the virus from establishing latency. Upon immunosuppression, the latent virus? however, reactivated but replicated at low titers. Interestingly, TK-deleted virus established latency and reactivation, that are occurred only in trigeminal ganglia and the cerebrums and no other tissues involved. Following reactivation, there was no indication of virus shedding in respiratory tissues as confirmed by virus isolation and polymerase chain reaction (PCR) technique targeting at the gB gene of PrV, The non-pathogenic virus with non-shedding characteristics, upon reactivation of the latent virus, would be the important feature of a live virus vaccine candidate.

A Case Study on the Effect of Fault Reactivation on Groundwater Flow around a Hypothetical HLW Repository (Fault Reactivation에 의한 가상 방사성폐기물 처분장 주변 지하수 유동 변화 평가 : 2차원 케이스 스터디)

  • Seo, Eun-Jin;Hwang, Yong-Soo;Han, Ji-Woong
    • Tunnel and Underground Space
    • /
    • v.16 no.4 s.63
    • /
    • pp.307-312
    • /
    • 2006
  • Radionuclide released from corroded container migrates through groundwater flow pathway in the underground rock. Therefore it is important to study the groundwater flow analysis for total system performance assessment of a HLW repository. In this study assuming a geological change of underground rock in future, the two dimensional groundwater flow analysis is done by the NAMMU, the assessment code for groundwater flow in porous media. Assuming the hypothetical repository with the reactivation of fault in the vicinity of it, the effect of change in aperture and permeability by reactivation of fault around a repository on groundwater pathway is studied.