• Title/Summary/Keyword: Reactive Loss Sensitivity Index

Search Result 8, Processing Time 0.022 seconds

Applications of System Loss Sensitivity Index to Power Systems (손실감도지표의 전력계통 적용)

  • Lee, Sang-Jung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.2
    • /
    • pp.56-61
    • /
    • 2000
  • In the paper, the system loss sensitivity index that implies the incremental system loss with respect to the change of bus power is derived using optimization technique. The index λ reaches $\infty$ at critical loading point and can be applied to actual power systems for following purposes. 1) Evaluation of system voltage stability 2)Optimal investment of reactive power focused on minimizing system loss and maximizing system voltage stability 3)Optimal re-location of reactive power focused on minimizing system loss and maximizing system voltage stability 4)Optimal load shedding in case of severe system contingency focused on minimizing system loss and maximizing system voltage stability. Case studies for each application have proved their effectiveness.

  • PDF

Voltage Collapse Approximity Indeces Using The Loss Sensitivity (손실 감도를 이용한 전압붕괴 근접도 지표)

  • Kim, Yang-B.;Kim, Kern-J.;Chu, Jin-B.;Kim, Woen-K.;Lee, Sang-J.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.218-221
    • /
    • 1992
  • Recent years voltage collapse phenomenon have a great attention to power system engineers. As the system size increases the voltage problem shows a very complicated and the reactive power contol problem becomes more difficult. This paper gives an efficient methods for calculating voltage collapse proximity index based on the reactive power loss sensitivity and real power loss sensitivity. The system voltages are tightly associated with the system reactive power, so the proposed voltage collapse proximity index is very usefull for the system voltage control problems. Numerical examples showed a good and reliable results.

  • PDF

Voltage collapse proximity index based on system apparent power loss sensitivity and its application to VAR investment (피상전력 손실감도에 의한 전압붕괴 근접도 지표와 무효전력 투자)

  • 이상중;김건중;김원겸;김용배;엄재선
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.44 no.10
    • /
    • pp.1290-1294
    • /
    • 1995
  • In this paper, a new voltage collapse proximity index (VCPI) based on system apparent power loss sensitivity is proposed. The newly proposed index .lambda.$^{Sloss}$ reaches -.inf. at system voltage collapse point and can be represented by .root..lambda.$^{Ploss}$$^{2}$+.lambda.$^{Qloss}$$^{2}$ where .lambda.$^{Ploss}$ and .lambda.$^{Qloss}$ are the VCPI based on the system active and reactive power loss sensitivity respectively. These indices can be used for the system VAR investment. .DELTA.Q [VAR] is invested, step by step, by the priority of the VCPI index given for each bus. The indices use information from normal power flow equations and their Jacobians. Computation time for deriving .lambda.$^{Sloss}$ is almost same as that for power flow calculation. Two case studies prove the effectiveness of the .lambda.$^{Sloss}$ index and the VAR investment algorithm proposed.

  • PDF

Optimal Voltage and Reactive Power Scheduling for Saving Electric Charges using Dynamic Programming with a Heuristic Search Approach

  • Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.329-337
    • /
    • 2016
  • With the increasing deployment of distributed generators in the distribution system, a very large search space is required when dynamic programming (DP) is applied for the optimized dispatch schedules of voltage and reactive power controllers such as on-load tap changers, distributed generators, and shunt capacitors. This study proposes a new optimal voltage and reactive power scheduling method based on dynamic programming with a heuristic searching space reduction approach to reduce the computational burden. This algorithm is designed to determine optimum dispatch schedules based on power system day-ahead scheduling, with new control objectives that consider the reduction of active power losses and maintain the receiving power factor. In this work, to reduce the computational burden, an advanced voltage sensitivity index (AVSI) is adopted to reduce the number of load-flow calculations by estimating bus voltages. Moreover, the accumulated switching operation number up to the current stage is applied prior to the load-flow calculation module. The computational burden can be greatly reduced by using dynamic programming. Case studies were conducted using the IEEE 30-bus test systems and the simulation results indicate that the proposed method is more effective in terms of saving electric charges and improving the voltage profile than loss minimization.

Coordinated Voltage and Reactive Power Control Strategy with Distributed Generator for Improving the Operational Efficiency

  • Jeong, Ki-Seok;Lee, Hyun-Chul;Baek, Young-Sik;Park, Ji-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1261-1268
    • /
    • 2013
  • This study proposes a voltage and reactive coordinative control strategy with distributed generator (DG) in a distribution power system. The aim is to determine the optimum dispatch schedules for an on-load tap changer (OLTC), distributed generator settings and all shunt capacitor switching on the load and DG generation profile in a day. The proposed method minimizes the real power losses and improves the voltage profile using squared deviations of bus voltages. The results indicate that the proposed method reduces the real losses and voltage fluctuations and improve receiving power factor. This paper proposes coordinated voltage and reactive power control methods that adjust optimal control values of capacitor banks, OLTC, and the AVR of DGs by using a voltage sensitivity factor (VSF) and dynamic programming (DP) with branch-and-bound (B&B) method. To avoid the computational burden, we try to limit the possible states to 24 stages by using a flexible searching space at each stage. Finally, we will show the effectiveness of the proposed method by using operational cost of real power losses and voltage deviation factor as evaluation index for a whole day in a power system with distributed generators.

An Integrated Mach-Zehnder Interferometric Sensor based on Rib Waveguides (Rib 도파로 기반 집적 마흐젠더 간섭계 센서)

  • Choo, Sung-Joong;Park, Jung-Ho;Shin, Hyun-Joon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.4
    • /
    • pp.20-25
    • /
    • 2010
  • An integrated Mach-Zehnder interferometric sensor operating at 632.8 nm was designed and fabricated by the technology of planar rib waveguides. Rib waveguide based on silica system ($SiO_2-SiO_xN_y-SiO_2$) was geometrically designed to have single mode operation and high sensitivity. It was structured by semiconductor fabrication processes such as thin film deposition, photolithography, and RIE (Reactive Ion Etching). With the power observation, propagation loss measurement by cut-back method showed about 4.82 dB/cm for rib waveguides. Additionally the chromium mask process for an etch stop was employed to solve the core damaging problem in patterning the sensing zone on the chip. Refractive index measurement of water/ethanol mixture with this device finally showed a sensitivity of about $\pi$/($4.04{\times}10^{-3}$).

A study on the optimal load shedding scheme considering the voltage stability improvement (전압안정도 개선을 고려한 적정 부하차단 기법)

  • 이상중;김건중;김원겸;김용배
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.44 no.3
    • /
    • pp.270-273
    • /
    • 1995
  • This paper proposes an optimal load shedding algorithm by which the system loss can be minimized when the load shedding is unavoidable in case of severe contingency such as the outage of key generators or lines. Shedding load .DELTA.S = .DELTA.P + J.DELTA.Q(MVA) is performed on the weakest bus (on the view of voltage stability), step by step, by the priority of the I.DELTA. = SQRT(.lambda.$\_$P/$\^$2/ + .lambda.$\_$Q/$\^$2/) index given for each load bus, where .lambda.$\_$P/ and .lambda.$\_$Q/ are the sensitivity indices representing the system loss variation versus active and reactive power change of the bus load bus. All loads are assumed to be constant power loads for convenience. A 5 bus sample system proves the effectiveness of the algorithm proposed.

Effects of HTS Cable Applied to the Voltage Stability Limited Power System (전압 안정도 제약계통에 대한 고온초전도 케이블 적용효과)

  • Lee, Geun-Joon;Hwang, Si-Dol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.169-173
    • /
    • 2004
  • This paper presents the basic application idea of superconductor cable for voltage stability limited power system. In bulk power system, the transfer capability of transmission line is often limited by the voltage stability, and superconductor cable could be one of the countermeasure to enhance heat transfer limit as well as voltage stability limit. Steady state voltage stability approach by P-V curve is used to calculate the maximum transfer capability of initial system and superconductor applied system. IEEE-14 bus system is used to demonstrate its applicability.