• Title/Summary/Keyword: Reagent strip

Search Result 24, Processing Time 0.028 seconds

A Simple Device of the Dry Tetrabromophenolphthalein Ethyl Ester Reagent Strip for the Detection of Methamphetamine

  • Choi, Myung-Ja;Song, Eun-Young;Kim, Seung-Ki;Choi, Jeong-Eun;Lho, Dong-Seok;Park, Jong-Sei
    • Archives of Pharmacal Research
    • /
    • v.16 no.3
    • /
    • pp.227-230
    • /
    • 1993
  • A new device to detect methamphetamine (MA), amphetamine(A) and its metabolites in urine was developed using the paper strip method and the test tube method of dry chemical reagents. The reagent containing tetrabromophenolphthalein ethyl ester (TBPE) and borax. For the TBPE paper strip method, a device was prepared with a window at each end of the reagent paper strip ; one window is for the sample application, and the other window is for the methylene chloride. The diffused sample from one window reacts with reagent in the paper and produces color at the point where it meets with methylene chloride which has diffused form the other side. A positive smaple produces as red-purple color and the negative sample a greenish color, with a detection limit of 5-10 ppm. The result can be obtained within one minute. For the TBPE test tube method which contains dry reagents, the detection limit is 5 ppm and the result can be obtaineed within 30 seconds, however the carry-on is not as convenient as the paper strip method. The performance of both methods were evlauated by comparing with the results of gas chromatography (GC) and fluorescence polarizaiton immunoassay (FPIA). The results were proven that both methods were useful as primary screening reagents to detect MA in urine and in dry powder.

  • PDF

The Study of Possibility of Finding a Reagent for Cancer Diagnosis by Urine NMR Measurement

  • Kim, Yong-J.
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.1
    • /
    • pp.35-40
    • /
    • 1986
  • For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

Usability of Urinary Reagent Strips in Diagnosis of Meningitis (뇌수막염의 진단에서 뇨검사 시험지를 이용한 뇌척수액 검사의 유용성)

  • Jeong, Jin Yeong;Park, Sang Kyu
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.2
    • /
    • pp.265-270
    • /
    • 1997
  • Purpose: Rapid diagnosis and prompt treatment remain the cornerstone of management of patients with meningitis. Examination of cerebrospinal fluid(CSF) for glucose, protein, cells, and organisms is necessary for accurate diagnosis, but in many parts of the world facilities do not exist to do so. We tested CSF samples from 69 children with suspected meningitis with urinary reagent strips and analyzed the results to know the usability of urinary reagent strips in diagnosis of meningitis. Methods: 69 CSF samples obtained from children with suspected meningitis were analysed. Each sample was divided into two; one was sent to the laboratory for routine diagnostic evaluation, and the other was tested with the reagent strip(Combur10 Test M). Laboratory values of CSF glucose, protein, and leucocytes for each CSF sample were plotted against the corresponding reagent-strip category. Results: There was good agreement between the dipstick and laboratory values for CSF protein and cell count but not for glucose. Conclusion: Rapid diagnosis of meningitis could be made with three component of the Combur10 test strip. It is easy to do and would be of particular value to those working in parts of the world where no laboratory facilities exist.

  • PDF

Color Correction in Portable-type Urine Analyzer

  • Kim, Jae-Hyung;Park, Chang-Hee;Lee, Seung-Jin;Jeon, Gye-Rok;Kim, Gi-Ryon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.21-26
    • /
    • 2002
  • Color correction methods of chromaticity coordinates using Color Matching Function (CMF) were studied to develop a device-independent portable-type urine analyzer. The reflection spectra were measured for the degrees of 10 test items of the urine reagent strip (urine strip) to develop a portable-type urine analyzer. A computer simulation was performed to quantitatively distinguish the color reactions of the urine system, by using the spectral power distribution of Light Emitting Diode(LED), the reflection of a urine strip, and spectral sensitivity of a photodiode. To develop a device-independent system, chromaticity coordinates were modified to reduce the color deviations in the urine strip, by using the temperature compensation of LED and the color transformation by CMF. The experimental values obtained by developed urine system exhibited the accuracy above 95% for all color samples.

Development of Clinical Chemistry Analyzer with the Dry Reagent Strip(I) (건습시약 스트립을 사용한 임상화학분석장치 개발[I])

  • Yoo, Dong-Joo;Jung, Tae-Hwa;Min, Hong-Kee;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.299-306
    • /
    • 1992
  • For quantitative measurement of reflected light from a clinical diagnostic scrip, a prototype of reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate re(leclance parameters. The strop was illuminated at $45^{\circ}C$ through optical fiber and the intensity of reflected light was determined at rectangulat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/dl about glucose, a saturation state of absorbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm.

  • PDF

A Study on Clinical Chemistry Analyzer Development by Using the Reflected Visible Light (가시 반사광을 이용한 임상화학 분석장치 개발의 기초연구)

  • Yoo, Dong-Joo;Jung, Tea-Hwa;Min, Hong-Kee;Huh, Woong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.144-147
    • /
    • 1992
  • In this paper, we study about reflectance photometer for measuring teflectance changes on reagent strip material after applying of a liguid sample. To obtain more accurate reflectance parameter, the strip loader and cassette is designed. The system is designed to work with IBM personal computer. As the experimental results, reflectance level measured of korean standard color paper and shows a exponentially proportion to brightness of paper. A diagnostic strip for total protein is applied to our system and shows a good correlation in a physically protein concentration range.(up to 500 mg/dl).

  • PDF

Development of Perforating Die for Manufacturing Fine Multi-perforated type Nail Files (미세 다수공 타입의 네일파일 제조용 퍼퍼레이팅 금형 개발)

  • 김세환
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.4
    • /
    • pp.309-314
    • /
    • 2004
  • 0.5mm thick steel is used to manufacture nail files. The first process is blanking and the second process is making about 300 holes of 0.8-l.0mm in diameter. This process depends mainly on etching which takes 33% of manufacturing cost and it can make manufacturing cost rise. The residual etching reagent is not environmentally friendly and the steel material is apt to rust as well. To solve these problems, researches on the following subjects are performed: proper material to prevent from rusting and strip layout strategies in stamping to replace etching process with press process which makes use of die. And new quill type punch is developed to replace the regular standard punch, one of the die parts, which frequently get broken while working. And these researches and developments lead to develop a progressive perforating die.

  • PDF

Implementation of Fuzzy Classifier and Automatic Turning for Urine Analyzer System using the Strip (스트립을 이용한 뇨분석 시스템의 퍼지 분류기 및 자동 튜닝 구현)

  • Kim, K.W.;Lee, S.J.;Kim, K.N.;Choi, B.C.;Ye, S.Y.;Jun, K.R.;Cho, J.W.;Kim, J.H.;Lee, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.141-142
    • /
    • 1998
  • The urine analysis system implemented to measuring the primary color reaction of urinalysis strip. Fuzzy classifier based on fuzzy theory implemented so as to classify of 9 items in the urinalysis strip and proposed the automatic turning algorithm of mambership function in the fuzzy classifier to progress the reproduction of classify. To evaluation of clinical capability, the fuzzy classifier and automatic turning algorithm apples to standard strip and standard reagent.

  • PDF

Vanillin의 신미량검출법 (제1보)

  • 이상섭;김용덕
    • YAKHAK HOEJI
    • /
    • v.3 no.1
    • /
    • pp.48-50
    • /
    • 1957
  • The micro-assay methods of vanillin have been shown quite few, though several methods have been introduced for determination. A new sensitive micro-determination of vanillin, applying the yellow color reaction of vanillin and anillin, is shown in this paper. The absorption maximum of the yellow coloring matter, 4-Oxy-3-methoxy-henzal aniline, was 435 mu. The one dimensional ascending paper chromatographic method is applyed for isolation of vanillin from the mixed sample. The microdetection of vanillin is studied only in this paper. Vanillin was detected by the yellow spot on paper trip by the coloring reagent of aniline after several hours paper strip chromatographic at the following condition; paper strip ................ 2.5 X 35cm Whatman Filter Paper No.2 developing Solvent ......... petroleum-benzene-methanol n-butanol-water coloring agent ............. aniline. The Rf-value on petroleum benzene and methanol was 0.63 and that on n-butanol and water was 0.90. The minimum detectable amount of vanillin by this method was 10 micrograms. It is recommendable, if interference substances as aromatic aldehydes present, that the application of this aniline reaction and Foline Denis reaction on the same paper chromatogram is appreciable.

  • PDF

Development of Urine Strip for Detection of Leukocytes in Urine using Peroxidase (과산화효소를 이용한 백혈구 측정용 뇨 검사지 제조에 관한 연구)

  • 송은영;이홍수;김희정;김종완;최인성;변시명;정태화
    • Biomedical Science Letters
    • /
    • v.2 no.2
    • /
    • pp.199-209
    • /
    • 1996
  • A new test strip to detect leukocytes using the myeloperoxidase in urine was developed. The reagent strip contains tetramethylbenzine, glucose and glucose oxidase. The detection limit was between 10 cells per 1$\mu$l urine(5 cells/hpf), showing greenish yellow color in the range of 10-25 cells/$\mu$l, green color in the range of 75-250 cells/$\mu$l, greenish blue color in the range of 500 cells/$\mu$l. The result can be obtained within two minute. The performance of the new method was evaluated by comparing the results of microscopic examination and other commercial products. Good correlations were shown between the values obtained by our urine strip and those by other commercial products with 172 urine samples. The results were proven that new methods were useful as primary screening reagents to detect leukocytes in urine.

  • PDF