• 제목/요약/키워드: Real-time Delivery Estimation

검색결과 11건 처리시간 0.026초

주문형 생산에서의 실시간 납기 산정 (Real-time Delivery Estimation in Build-to-order Manufacturing)

  • 홍태영;강무진;박세형;이상봉
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2002
  • Leading companies have embraced the new economy with new and innovative BTO models. Instead of conventional company-oriented manufacturing scheduling, customer-oriented scheduling method attracts more and more attention. To evaluate the delivery of customer order in advance, the real production capacity as well as procurement lead time should be taken into account. This paper describes a quasi-real-time order delivery estimation system using TOC(Theory of Constraints) based scheduling method.

  • PDF

SSMS에서 동적 공구할당을 고려한 부품투입 알고리즘의 시뮬레이션 분석 (Simulation Analysis of Part Release Algorithm under Dynamic Tool Allocation in SSMS)

  • 이충수
    • 한국시뮬레이션학회논문지
    • /
    • 제8권1호
    • /
    • pp.63-76
    • /
    • 1999
  • Recently in manufacturing environment, manufacturing order is characterized by unstable market demand, shorter product life cycle, a variety of product and shorter production lead time. In order to adapt this manufacturing order, flexible manufacturing systems(FMS) in manufacturing technology advances into the direction that machines become further versatile functionally and that tools are controlled by fast tool delivery device. Unlike conventional FMS to mainly focus on part flow, it is important to control tool flow in single-stage multimachine systems(SSMS), consisting of versatile machines and fast tool delivery device. This research is motivated by the thought that exact estimation of tool competition at part release in SSMS enhances the system performance. In this paper, in SSMS under dynamic tool allocation strategy to share tools among machines, we propose real-time part release and tool allocation algorithms which can apply real factory and which can improve system performance.

  • PDF

호흡동조방사선치료 시 Real Time Monitor와 Ventilator의 유용성 평가 (Utility Estimation of the Application of Auditory-Visual-Tactile Sense Feedback in Respiratory Gated Radiation Therapy)

  • 조중훈;김병진;노시원;이현찬;장형준;김회남;송재훈;김영재
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.33-40
    • /
    • 2013
  • 목 적: 호흡동조방사선치료 시 호흡에 따른 종양의 위치를 정확하게 파악하여 치료하기 위해서는 안정되고 일정한 호흡유지가 중요하다. 이에 본 연구에서 Real time monitor와 Ventilator를 이용하여 측정한 호흡유지방법을 소개하고 그 유용성을 평가하고자 한다. 대상 및 방법: 7명의 실험자를 대상으로 하여 Gate on time (Beam on time) 600초를 기준으로 실험자를 총 5개의 그룹 -자연 호흡, Monitor를 이용하여 유도한 호흡, Ventilator를 이용하여 유도한 호흡, Monitor와 Ventilator를 동시에 이용하여 유도한 호흡, 실험자 스스로 Real time monitor를 이용하여 주기적 Breath-hold 상태를 유지하는 호흡- 으로 분류 하였다. 분류 후 ANZAI 4D system을 이용하여 각각의 호흡신호를 획득 하였다. 호흡신호별 총 소요 시간을 비교하고 호흡주기 상의 Gate on/off time 평균값, 표준편차, 분산, 평균 호흡 주기의 횟수와 변화 등을 각각 분석하여 호흡의 안정성을 평가 하였다. 동시에 실험자들을 대상으로 설문조사를 실시하여 각 장치들의 의존성을 정성적으로 조사하였다. 결 과: 5개 그룹의 호흡신호 편차변화를 비교하여 실험자의 각 호흡신호 안정성을 평가하였다. 그 결과 모든 실험자는 Gate on time 600초 동안 소요되는 시간이 Monitor와 Ventilator를 동시에 사용 했을 경우에 실험시간이 가장 짧게 걸렸고, 가장 안정된 호흡을 유지한 것으로 나타났다. 결 론: 본 연구에서 Real time monitor와 Ventilator를 사용하여 호흡유도를 진행해본 결과 실험대상자들의 안정적인 호흡유지에 유용성이 있는 것으로 나타났다. 2개의 장비를 독립적으로 사용하였을 경우 보다 동시에 사용할 경우 호흡유지 안정도가 더 우수한 것으로 나타났다. Real time monitor와 Ventilator를 이용하여 환자의 호흡조건을 설정하여 환자에게 적용시킨다면 호흡조절방사선치료 시 치료의 정확도를 높일 수 있으리라 예상되며 동시에 치료시간도 단축될 것으로 사료된다. 특히 규칙적인 호흡조절이 가능한 환자의 경우 Real time monitor를 활용한 Breath-hold 방법의 활용은 치료시간 단축의 효과를 현저히 높일 수 있을 것이라 사료된다.

  • PDF

2축 짐벌 구조 적재 장치를 위한 최소제곱법 기반 시스템 식별 (Least Squares Method-Based System Identification for a 2-Axes Gimbal Structure Loading Device)

  • 심예리;진상록
    • 로봇학회논문지
    • /
    • 제17권3호
    • /
    • pp.288-295
    • /
    • 2022
  • This study shows a system identification method of a balancing loading device for a stair climbing delivery robot. The balancing loading device is designed as a 2-axes gimbal structure and is interpreted as two independent pendulum structures for simplifying. The loading device's properties such as mass, moment of inertia, and position of the center of gravity are changeable for luggage. The system identification process of the loading device is required, and the controller should be optimized for the system in real-time. In this study, the system identification method is based on least squares method to estimate the unknown parameters of the loading device's dynamic equation. It estimates the unknown parameters by calculating them that minimize the error function between the real system's motion and the estimated system's motion. This study improves the accuracy of parameter estimation using a null space solution. The null space solution can produce the correct parameters by adjusting the parameter's relative sizes. The proposed system identification method is verified by the simulation to determine how close the estimated unknown parameters are to the real parameters.

H.264 표준 동영상 부호화 방식을 위한 순차적 움직임 벡터 오류 은닉 기법 (Sequential Motion Vector Error Concealment Algorithm for H.264 Video Coding)

  • 정종우;홍민철
    • 한국통신학회논문지
    • /
    • 제30권10C호
    • /
    • pp.1036-1043
    • /
    • 2005
  • 본 논문에서는 H.264 표준 동영상 부호화 방식을 위한 순차적 움직임 벡터 오류 은닉 기법에 대해 제안한다. H.264 표준 동영상 부호화 방식에서의 움직임 예측과정은 다양한 크기의 서브 매크로 블록 모드에 따라 각기 다른 움직임 벡터 개수를 갖게 되고, 이로 인해 움직임 벡터는 기존의 표준 부호화 방식에 비해 상대적으로 적은 영역을 대표하게 된다. 그러므로 이웃한 블록의 움직임 벡터간의 상관관계는 서브 매크로 블록의 크기가 작을수록 더 커지게 된다. 제안 방식에서는 변화된 국부 통계 특성에 대한 적응도에 따른 $\alpha$-trimmed mean 필터를 이용하여 움직임 벡터를 순차적으로 복구하는 움직임 벡터 오류 은닉기법에 대해 제안한다. 실험 결과를 통해 제안한 방식이 실시간 동영상 전송에 적합하며 기존의 블록 경계 정합 방식 및 라그랑즈 보간 방식과 유사한 성능을 보임을 확인할 수 있었다.

고품질 실시간 스트리밍 서비스 제공을 위한 네트워크 모니터링 기법 (Network Monitoring Mechanism For High Quality Real-Time Streaming Service)

  • 김용술;김화성
    • 한국통신학회논문지
    • /
    • 제31권11B호
    • /
    • pp.969-978
    • /
    • 2006
  • 멀티미디어 서비스의 증가는 인터넷 콘텐츠의 새로운 국면으로 나타나고 있다. IP텔레폰, 화상채팅과 같은 멀티미디어 서비스는 대역폭, 지터, 패킷유실, 전송지연 듯의 네트워크 파라미터에 민감한 데이터이다. 멀티미디어 서비스의 QoS 보장을 위해서 RTP/RTCP를 이용하여 네트워크 상황을 판단하고 전송률을 조절하는 기법이 연구되고 있다. 본 논문에서는 최선형(Best-Effort) 서비스를 제공하는 현 인터넷 구조에서 RTP/RTCP 구조를 확장하여 단방향 전송 지연시간을 구하고 이를 이용하여 네트워크 상황을 판단하는 기법을 제안한다. 또한 단방향 전송지연을 이용하여 급변하는 네트워크 상황에 즉각적으로 대처하기 위한 동적인 RTCP 구조를 제안한다. 모의 실험결과 제안한 단방향 전송 지연 기법은 GPS를 이용한 단방향 전송 기법과 유사한 성능을 보였으며, 제안한 동적 RTCP 기법은 적은 RTCP RR패킷 전송으로 패킷 손실률이 감소하는 효과를 얻었다.

병원중심 가정간호관리대상 범위 확대를 위한 기초연구(II) - 자동차보험가입 입원환자를 대상으로 - (A Preliminary Study for Expending of Hospital-Based Home Health Care Coverage - Focused on Car Accident Inpatients Who has the Compensation Insurance -)

  • 박은숙;이숙자;박영주;유호신
    • 가정간호학회지
    • /
    • 제7권1호
    • /
    • pp.58-72
    • /
    • 2000
  • This study was an attempt to encourage the development of a rehabilitation delivery system and programs as a substitute service for hospitalization on the case of car accident patients, such as hospital based home health care nursing services. Various substitute services for hospitalization are required to curtail the length of stay for inpatients who were hospitalized with car accident compensation insurance. It focused on developing an estimation an early discharge day for car accident inpatients based on detailed statements of treatment for 111 inpatients who were hospitalized at the General Hospital in 1997. This study had four specific purposes as follows. First. to find out the utilization of medical services. Second, to estimate the time of early discharge and income increasing effect based on early discharge for those patients. Third, to identify the factors affecting total medical expenditure and the length of stay for those inpatients. Forth, to figure out the need of utilizing home health care nursing service for accident patients. In order to analyze the length of stay and medical expenditure for inpatients who were hospitalized due to car accidents, the authors conducted micro- and macro-analysis of medical and medical expenditure records. Micro-analysis was done by nominal group discussion of 4 expertise with the critical criteria, such as a decrease in the amount of treatment after surgery, treatments, tests, drugs and changes in the test consistency, drug methods, vital signs, start of ROM exercise, doctor's order, patient's outside visiting ability, and stable conditions. In addition to identifying variables affecting medical expenditure, and the length of stay and income effect due to early discharge day, the data was analyzed with a multiple regression analysis and linear regression analysis model by SPSS-PC for windows and Excell program. Results of this study were as follows. First. the mean length of stay was 50.3 days. whereas the mean length of stay due to early discharge was 34.3 days at the hospital. The estimation of time of early discharge depended on the length of stay. The longer the length of stay, the longer the length of time of early discharge : for instance a length of stay under 10 days was estimated as correlating to a mean length of stay of 6.6 days and early discharge of 6.5. The mean length of stay was 217.4 days and the time of early discharge was 110.1 respectively. The mean medical expenditure per day was found to be 169.085 Won and the mean medical expenditure per day showed negative linear trends according to the length of stay at the hospital. The estimation results of the income effect due to being discharged 16 days early was around 2,244,000 won per bed. However. this sum does not represent the real benefits resulting from early discharge, but rather the income increasing amount without considering medical prime cost in the general hospital. Therefore, further analysis is required on the cost containments and benefits as turn over rate per bed as the medical prime costs. The length of stay was most significant and was positive to the total medical expenditure, as expected. Surgery and patient's residential area was also an important variable in explaining medical expenditure. The level of complications was the most significant variable in explaining the length of stay. There was a high level for need a home health care nursing service which further supports early discharge for accident patients. In addition, when the patient was discharged. they needed follow up care for complications suffered during the car accident. $86.8\%$ of discharged patients responded that they needed home health services after early discharge. From these research findings, the following suggestions have been drawn. Strategies on a health care delivery system must be developed in order to focus on the consumer's needs and being planned for 21 century health policy in Korea. Community based intermediate facilities or home health care should be developed for rehabilitation services as a substitute for hospitalization in order to shorten the length of stay would be. A hospital based home health care nursing service. it would be available immediately to utilize by patients who want rehabilitation services as a substitute for hospitalization with the cooperation of car insurance companies.

  • PDF

3차 병원에 입원한 교통사고환자의 평균 재원기간과 조기퇴원시의 수입증대효과 분석연구 (Analyses on the Mean Length of Stay of and the Income Effects due to Early Discharge of Car Accident Patients at General Hospital)

  • 유호신
    • 지역사회간호학회지
    • /
    • 제10권1호
    • /
    • pp.70-79
    • /
    • 1999
  • This study attempts to encourage the development of a rehabilitation delivery system as a substitute service for hospitalization such as a community based intermediate facility or home health care. We need substitute services for hospitalization to curtail the length of stay for inpatients due to car accidents. It focused on developing an estimation for early discharge based on a detailed statement of treatment from medical records of 109 inpatients who were hospitalized at General Hospital in 1997. This study has three specific purposes: First, to find the mean length of stay and mean medical expenditure. Second, to estimate the mean of early discharge from the mean length of stay. Third, to analyize the income effect per bed from early discharge. In order to analyze the length of stay and medical expenditure of inpatients the author conducted a micro and macro-analysis with medical expenditure records. To estimate the early discharge we examined with a group of 4 experts decreases in the amount of treatment after surgery, in treatments, in tests, in drug methods. We also looked their vital signs, the start of ROM exercise, the time removel, a patient's visitations, and possible stable conditions. In addition to identifing the income effect due to an early discharge, the data was analyzed by an SPSS-PC for windows and Excell program with a regression analysis model. The research findings are as follows: First, the mean length of stay was 47.56 days, but the mean length of stay due to early discharge was 32.26 days. The estimation of early discharge days was shown to depend on the length of stay. The longer the length of stay, the longer the length before discharge. For example, if the patient stayed under 14 days the mean length of stay was 7.09 while an early discharge was 6.39, whereas if the mean length of stay was 155.73, the early discharge time was 107.43. The mean medical expenditure per day of car accident patients was found to be 169,085 Won, whereas the mean medical expenditure per day was shown to be in a negative linear form according to the length of stay. That is the mean expenditure for under 14 days of stay was 303,015 Won and the period of the hospitalization of 15 days to 29 days was 170,338 Won and those of 30 days to 59 days was 113,333 Won. The estimation of the income effect due to being discharged 16 days was around 2,350,000 Won with a regression analysis model. However, this does not show the real benefits from an early discharge, but only the income increasing amount without considering prime medical cost at a general hospital. Therefore, we need further analysis on cost containments and benefits incending turn over rates and medical prime costs. From these research findings, the following suggestions have been drawn, we need to develop strategies on a rehabilitation delivery system focused on consumers for the 21st century. Varions intermediate facilities and home health care should be developed in the community as a substitute for shortening the length of stay in hospitals. In home health care cases, patients who want rehabilitation services as a substitute for hospitalization in cooperation with private health insurance companies might be available immediately.

  • PDF

운전자 시선 및 선택적 주의 집중 모델 통합 해석을 통한 운전자 보조 시스템 (Driver Assistance System for Integration Interpretation of Driver's Gaze and Selective Attention Model)

  • 김지훈;조현래;장길진;이민호
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권3호
    • /
    • pp.115-122
    • /
    • 2016
  • 본 논문은 차량의 내부 및 외부 정보를 통합하여 운전자의 인지 상태를 측정하고, 안전운전을 보조하여 주는시스템을 제안한다. 구현된 시스템은 운전자의 시선 정보와 외부 영상을 분석하여 얻은 주변정보를 mutual information기반으로 통합하여 구현되며, 차량의 앞부분과 내부 운전자를 검출하는 2개의 카메라를 이용한다. 외부 카메라에서 정보를 얻기 위해 선택적 집중모델을 기반으로 하는 게슈탈트법칙을 제안하고, 이를 기반으로 구현된 saliency map (SM) 모델은 신호등과 같은 중요한 외부 자극을 두드러지게 표현한다. 내부 카메라에서는 얼굴의 특징정보를 이용하여 운전자의 주의가 집중되는 외부 응시 정보를 파악하고 이를 통해 운전자가 응시하고 있는 영역을 검출한다. 이를 위해서 우리는 실시간으로 운전자의 얼굴특징을 검출하는 알고리즘을 사용한다. 운전자의 얼굴을 검출하기 위하여 modified census transform (MCT) 기반의 Adaboost 알고리즘을 사용하였으며, POSIT (POS with ITerations)알고리즘을 통해 3차원 공간에서 머리의 방향과 운전자 응시 정보를 측정하였다. 실험결과를 통하여 제안한 시스템이 실시간으로 운전자의 응시하고 있는 영역과, 신호등과 같은 운전에 도움이 되는 정보를 파악하는데 도움이 되었음을 확인할 수 있으며, 이러한 시스템이 운전보조 시스템에 효과적으로 적용될 것으로 판단된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF