• Title/Summary/Keyword: Reference Signal Synthesized Method

Search Result 4, Processing Time 0.021 seconds

Exhaust Noise Control with the Active Muffler in Exhaust System of Vehicle (상용차 배기계에서 액티브 머플러를 이용한 배기 소음 제어)

  • 김홍섭;홍진석;오재응;송진호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.36-42
    • /
    • 1998
  • In this study, active muffler was designed and was manufactured for exhaust noise reduction of commercial vehicle, then experiment of real vehicle was conducted. In a manufactured active muffler, because the flow of exhaust noise in tail pope outlet are become a plane wave, the global reduction if radiation noise from outlet and the placement of error microphone to avoid the exhaust gas of high temperature could be implemented. In control algorithm, reduction of noise of engine driving frequency and harmonic frequency can be archieved using proposed reference signal including a fixed speed state(2,000rpm, 3,000rpm, 4,000rpm) and a run-up speed state(2,000rpm$\rightarrow$4,000rpm) is accomplished with the active muffler installed in vehicle.

  • PDF

Low sidelobe digital doppler filter bank synthesis algorithm for coherent pulse doppler radar (Coherent 레이다 신호처리를 위한 저부엽 도플러 필터 뱅크 합성 알고리즘)

  • 김태형;허경무
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.3
    • /
    • pp.612-621
    • /
    • 1996
  • In this paper, we propose the low sidelobe digital FIR doppler filter bank synthesis algorithm through the Gradient Descent method and it can be practially appliable to coherent pulse doppler radar signal processing. This algorithm shows the appropriate calculation of tap coefficients or zeros for FIR transversal fiter which has been employed in radar signal processor. The span of the filters in the filter bank be selected at the desired position the designer want to locate, and the lower sidelobe level that has equal ripple property is achieved than one for which the conventional weithtedwindow is used. Especially, when we implemented filter zeros as design parameters it is possible to make null filter gain at zero frequency intensionally that would be very efficient for the eliminatio of ground clutter. For the example of 10 tap filter synthesis, when filter coefficients or zeros are selected as design parameters the corresponding sidelobelevel is reducedto -70db or -100db respectively and it has good convergent characteristics to the desired sidelobe reference value. The accuracy ofapproach to the reference value and the speed of convergence that show the performance measure of this algorithm are tuned out with some superiority and the fact that the bandwidth of filter appears small with respect to one which is made by conventional weighted window method is convinced. Since the filter which is synthesized by this algorithm can remove the clutter without loss of target signal it strongly contributes performance improvement with which detection capability would be concerned.

  • PDF

Depth-map Preprocessing Algorithm Using Two Step Boundary Detection for Boundary Noise Removal (경계 잡음 제거를 위한 2단계 경계 탐색 기반의 깊이지도 전처리 알고리즘)

  • Pak, Young-Gil;Kim, Jun-Ho;Lee, Si-Woong
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.12
    • /
    • pp.555-564
    • /
    • 2014
  • The boundary noise in image syntheses using DIBR consists of noisy pixels that are separated from foreground objects into background region. It is generated mainly by edge misalignment between the reference image and depth map or blurred edge in the reference image. Since hole areas are generally filled with neighboring pixels, boundary noise adjacent to the hole is the main cause of quality degradation in synthesized images. To solve this problem, a new boundary noise removal algorithm using a preprocessing of the depth map is proposed in this paper. The most common way to eliminate boundary noise caused by boundary misalignment is to modify depth map so that the boundary of the depth map can be matched to that of the reference image. Most conventional methods, however, show poor performances of boundary detection especially in blurred edge, because they are based on a simple boundary search algorithm which exploits signal gradient. In the proposed method, a two-step hierarchical approach for boundary detection is adopted which enables effective boundary detection between the transition and background regions. Experimental results show that the proposed method outperforms conventional ones subjectively and objectively.

A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements (웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구)

  • Lee, Kang-Hwi;Lee, Seong-Su;Kim, Sang-Min;Lee, Hyeok-Jae;Min, Kyoung-Jin;Kang, Hyun-Kyu;Lee, Joo-Hyeon;Kwak, Hwy-Kuen;Ko, Yun-Soo;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.