• Title/Summary/Keyword: Reflective Measurement

Search Result 124, Processing Time 0.027 seconds

Reflective Signal Based Signal Contioning of Capacitive Sensor and High Precision Gap Measurement (반사 신호를 이용한 용량 성 센서의 신호처리 및 이를 이용한 초정밀 간극 측정)

  • Kim, Jae-Geun;Lee, Taek-Joo;Lim, Soo-Cheol;Park, Kyoung-Soo;Park, No-Cheol;Park, Young-Pil;Ohm, Won-Suk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.537-537
    • /
    • 2010
  • High precision sensing is very important in various technologies. Especially, it is more important when it were applied to nano/micro meter level's sensing like AFM, storage, etc. And capacitive sensing is widely used method. To improve the measurement efficiency, many signal conditioners were studied and one of them was surface acoustic wave (SAW) device. SAW device is very widely used as a high frequency bandwidth filter. Due to the reflective characteristic of high frequency, the response of SAW device contains both propagative and reflective signal at the external impedance. In this paper, we used SAW device as signal conditioner of capacitive sensor. And high precision gap measurement was executed using capacitive load. Reference signal was reflective SAW response and the magnitude at the center frequency of SAW device by the change of impedance was checked. Finally, the attainable gap resolution was determined.

  • PDF

Effects of reflective film treatments on fruit quality attributes and peel color variables in 'Fuji' apple fruit

  • Jingi, Yoo;Jung-Geun, Kwon;In-Kyu, Kang
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.3
    • /
    • pp.521-529
    • /
    • 2022
  • This study evaluated the effects of agricultural reflective film and HANSPEK film on the fruit quality attributes and peel color variables of 'Fuji' apples. The reflective films were applied under the tree canopies at 20 and 30 days before harvest (DBH), and a tree with no films was used as the control. Depending on the measurement locations, the light intensity was 7.4 - 14.6% higher in the reflective film treatments than that of the control. However, no difference in the light intensity was observed between the reflective and HASPEK films. In addition, the light intensity was not also different between the 20 and 30 DBH. At harvest, the flesh firmness, fruit weight, soluble solids content, titratable acidity, and internal ethylene concentration were not different regardless of the type of reflective film and treatment time. In addition, the peel color variables were not affected in the equatorial region. However, in the calyx region, the L* and b* values were decreased, and the a* value was increased by the reflective and HANSPEK films compared with the control. Hence, the hue angle was decreased to near 0o (red), and the peel color was improved. Therefore, this study suggests that the application of the HANSPEK film under a tree canopy could improve the fruit peel color of 'Fuji' apples.

A study on the development and performance evaluation of reflective type Heart rate measurement system for PAPS (PAPS를 위한 반사형 맥파 측정 장치의 개발 및 성능 평가)

  • Kim, Sheen-Ja;Lee, Young-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.1
    • /
    • pp.160-166
    • /
    • 2012
  • We performed the development and performance evaluation of reflective type heart rate measurement system for PAPS. We used chip LED and chip photo TR. for low power driving. The measured PPG signal is preprocessed using high pass filter and low pass filter, and the preprocessed signal is displayed by LabVIEW. Also LabVIEW include the algorithm that extract effective signal and calculate the heart rate. We made sure that it will be able to apply to measurement equipment with high accuracy and repetition from exercising subject using this system and algorithm.

Reflective Fourier Ptychographic Microscopy Using Segmented Mirrors and a Mask

  • Ahn, Hee Kyung;Chon, Byong Hyuk
    • Current Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.40-44
    • /
    • 2021
  • In this paper, LED arrays with segmented mirrors and a mask are presented as a new dark-field illuminator for reflective Fourier ptychographic microscopy (FPM). The illuminator can overcome the limitations of the size and the position of samples that the dark-field illuminator using a parabolic mirror has had. The new concept was demonstrated by measuring a USAF 1951 target, and it resolved a pattern in group 10 element 6 (274 nm) in the USAF target. The new design of the dark-field illuminator can enhance competitiveness of the reflective FPM as a versatile measurement method in industry.

Measurement of Refractive Power by Reflective image on the Negative Spherical Lens ((-) 구면 렌즈 면의 반사상에 의한 굴절력 측정)

  • Choi, Woon-Sang;Kim, Tae-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.417-421
    • /
    • 2004
  • We can see that two images of reflection are observed on the surface of a ophthalmic lens. These are the image reflected from front surface and back surface of lens, respectively. The reflective image shows to be affect by surface refractive power of front and back surface of lens. Total refractive power of lens is calculated by refractive power of front and back surface of lens. Accordingly, the ratio of image on the lens surface is able to measure refractive power of ophthalmic lens without helping of the lensmeter. The ratio of two reflective image measured on the lens surface is compared with the calculated ratio by the power measurement.

  • PDF

Development of Formative Constructs and Measurements for Performance Evaluation of Information Systems (정보시스템 성과평가를 위한 형성적 구성변수(Constructs) 및 측정지표 개발)

  • Kim, Sanghoon;Kim, Changkyu
    • Journal of Information Technology Services
    • /
    • v.11 no.4
    • /
    • pp.135-151
    • /
    • 2012
  • Traditionally in IS studies, the relationship between construct and its measurement items tends to be assumed to be reflective, meaning that the measurements are a reflection of the construct. In reality, however, the nature of the construct can be often formative, which means that its measurement items describe and define the construct rather than vice versa. The purpose of this study was to investigate theoretical and empirically-analysed differences between formative construct and reflective construct through comprehensive interdisciplinary literature review. And then on the basis of these differences, we intended to derive the rule of specifying whether the construct is formative or reflective and propose the methodology of testing the validity(content validity, construct validity, internal consistency and external construct) of formative construct and its measurements, differentiated from that in the case of reflective construct. Also, we suggested the concrete statistical testing methods such as VTT(Vanishing Tetrad Test), MIMIC(Multiple Indicators and Multiple Causes) test and multi-collinearity test. In order to examine the applicability of this methodology to developing the constructs for performance evaluation of IS(Information Systems), we tried to identify its attribute(formative or reflective) and test the validity for the construct arbitrarily chosen among them which had been derived in our previous IS performance evaluation study by using this methodology. The result of the examination was that the methodology proposed in this study was significantly valid and effective in the area of IS performance evaluation.

Considerations for error factors in four measurement systems determined in JEITA standard ED2523 (Measuring methods for matrix reflective LCD modules)

  • Narutaki, Yozo;Sakai, Eiji;Shimizu, Shinji;Tsuda, Keisuke;Uehara, Masao;Uehara, Toshinori;Katoh, Shinsuke;Yoda, Yuji
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1362-1365
    • /
    • 2008
  • ED-2523 (Measuring methods for matr ix reflective LCD modules) was published by JEITA (Japan Electronics and Information Technology Industries Association) in 2001. Since then, round robin tests had been done and the accuracy of measurement values had been discussed. In this paper, considerations for error factors in four measurement systems are showed.

  • PDF

Tolerance Allocation Method for IR Optics Fabrication Using Monte-Carlo Simulation Based on Measured Reflective Eccentricity (편심측정 결과가 반영된 몬테카를로 시뮬레이션을 이용한 적외선 광학계 조립정렬 공차 할당 기법)

  • Yoo, Jae-Eun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.4
    • /
    • pp.161-169
    • /
    • 2011
  • In this paper, a tolerance allocation method using Monte-Carlo simulation with measured reflective eccentricity for high-sensitive IR optics is proposed. During optics fabrication and alignment, reflective eccentricity was measured using an optical centration measurement instrument. A Monte-Carlo simulation was performed using measured eccentricity data, and it gives statistical estimated performance of the optics after fabrication. The validity of the proposed tolerance allocation method was verified comparing the estimated MTF result with the measured MTF result of the fabricated optics.

Characteristics of Measurement Errors due to Reflective Sheet Targets - Surveying for Sejong VLBI IVP Estimation (반사 타겟의 관측 오차 특성 분석 - 세종 VLBI IVP 결합 측량)

  • Hong, Chang-Ki;Bae, Tae-Suk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.325-332
    • /
    • 2022
  • Determination of VLBI IVP (Very Long Baseline Interferometry Invariant Point) position with high accuracy is required to compute local tie vectors between the space geodetic techniques. In general, reflective targets are attached on VLBI antenna and slant distances, horizontal and vertical angles are measured from the pillars. Then, adjustment computation is performed by using the mathematical model which connects measurements and unknown parameters. This indicates that the accuracy of the estimated solutions is affected by the accuracy of the measurements. One of issues in local tie surveying, however, is that the reflective targets are not in favorable condition, that is, the reflective sheet target cannot be perfectly aligned to the instrument perpendicularly. Deviation from the line of sight of an instrument may cause different type of measurement errors. This inherent limitation may lead to incorrect stochastic modeling for the measurements in adjustment computation procedures. In this study, error characteristics by measurement types and pillars are analyzed, respectively. The analysis on the studentized residuals is performed after adjustment computation. The normality of the residuals is tested and then equal variance test between the measurement types are performed. The results show that there are differences in variance according to the measurement types. Differences in variance between distances and angle measurements are observed when F-test is performed for the measurements from each pillar. Therefore, more detailed stochastic modeling is required for optimal solutions, especially in local tie survey.

Reflective Liquid Crystal Cell Parameters Measurement

  • Valyukh, S.;Valyukh, I.;Adas, C.;Chigrinov, V.;Skarp, K.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.479-482
    • /
    • 2004
  • We report a method for simultaneous measurements of cell gap, twist angle, birefringence dispersion of liquid crystal (LC) material and alignment directions in filled reflective LC cells. The method is based on spectral measurements of the LC cell reflectivity for three orientations ($0^{\circ},45^{\circ},90^{\circ}$) of the exit polarizer and may be applied for LC cells with low and high gaps.

  • PDF