• Title/Summary/Keyword: Reinforcement of denture

Search Result 27, Processing Time 0.036 seconds

A COMPARATIVE STUDY ON THE SEVERAL METAL REINFORCEMENT METHODS OF MAXILLARY COMPLETE ACRYLIC RESIN DENTURE BASE (수종의 상악 총의치수지상 금속보강법에 관한 비교연구)

  • Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.363-372
    • /
    • 1996
  • A common site of fracture in maxillary complete denture is on the anteroposterior midline that coincides with the notch for relief of the labial frenum. Various approaches to reduce the incidence of this type of fracture have been suggested. The most widely used technique is the reinforcement of acrylic resin denture base with several solid metal forms. But few comparative studies on the efficacy of metal reinforcements have been reported. This study was conducted to compare reinforcing effects of commonly available metal reinforcements, which include wire, metal mesh embedded in the denture base and metal plate affixed to the impression surface of denture base by silicoating technique. This was load on the posterior. The strain gauges were oriented perpendicular to the anteroposterior midline of maxillary polished denture surface at one labial and the four palatal sites Non-renforced denture was used as control. The results were as follows : 1. In the non-reinforced denture group, only tensile strains on the palatal polished surface were observed. The tensile strains decreased in the order of incisive papilla, posterior denture border area, mid palatal area and rugae area. Compressive strain was observed on the labial polished surface. 2. As compared with the non-reinforced denture group, the metal plate or the metal mesh reinforced denture groups showed reduced palatal tensile strains,and the metal mesh reinforcement had a better reinforcing effect than the metal plate. But both reinforced denture groups showed no difference in the amount of compressive strain on the labial polished surface when compared to the non-reinforced denture group. 3. The metal wire positioned just above the labial notch decreased the compressive strain on the labial polished surface. But the presence of metal wires in the palatal polished surface caused increase in tensile strains in the area.

  • PDF

Evaluation of fitness according to application of glass fiber reinforcement for lower jaw complete denture (하악 총의치 전용의 유리섬유 보강재 적용에 따른 적합도 비교 분석)

  • Kim, Dong-Yeon;Park, Jin-Young;Bae, So-Yeon;Kang, Hoo-Won;Kim, Ji-hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.40 no.4
    • /
    • pp.201-207
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the fitness of lower jaw compete denture with glass fiber. Methods: Lower jaw edentulous model was selected as the master model. Ten study models were produced using Type IV stone(n=10). Lower jaw trial dentures were produced by the wax denture base and artificial teeth. Conventional complete denture (CD) group was fabricated by excluding glass fiber reinforcement (n=5). Glass fiber complete denture (GD) group was fabricated with glass fiber reinforcement (n=5). The lower jaw trial complete denture was invested using a plaster. PMMA resin was injected and curing was performed. The CD and GD groups measured the fit using silicone replica technology. The measured data was verified by t-test. Results: The anterior area of the CD group showed the smallest value. There was a statistically significant difference in the anterior area of the CD group and the GD group (p<0.05), but there was no statistically significant difference in the posterior area (p>0.05). Conclusion : Complete denture with glass fiber showed low fitness and further study is needed to apply it clinically.

Comparison of metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture (상악 총의치 정중 파절 수리 시 금속선 및 유리섬유의 보강효과 비교)

  • Lee, Jung-Ie;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.284-291
    • /
    • 2013
  • Purpose: This study compared fracture strength and fracture modes between metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture. Materials and methods: In this study, fracture was reproduced on center of maxillary complete dentures and the denture was repaired with auto-polymerizing resin. The experimental groups (n = 10) were subjected to the following condition: without reinforcing material (control group), reinforcing with metal wire (W group), reinforcing with glass fiber pre-impregnated with light-curing resin (SES MESH, INNO Dental Co., Yeoncheon, Korea, G group). The fracture strength and fracture modes of a maxillary complete denture were tested using Instron test machine (Instron Co., Canton, MA, USA) at a 5.0 mm/min crosshead speed. The flexure load was applied to center of denture with a 20 mm diameter ball attachment. When fracture occurred, the fracture mode was classified based on fracture lines. The Kruskal-wallis test and the Mann-whitney U test were performed to identify statistical differences at ${\alpha}=.05$. Results: W group showed the highest value of fracture strength, there was no significant difference (P>.05) between control group and G group. Control group and W group showed anteroposterior fracture mainly, group W showed adhesive fracture of denture base and reinforcing material. Conclusion: In limitation of this study, the glass fiber did not improve the fracture strength of repaired maxillary complete denture, and adhesive failure was occurred along the lines of glass fiber.

Analysis of Partial Denture through Topology Optimization Design (위상최적설계를 통한 가공의치의 해석)

  • Lee, Jeong-Ick;Koh, Byung-Kab
    • Korean Journal of Computational Design and Engineering
    • /
    • v.11 no.5
    • /
    • pp.351-358
    • /
    • 2006
  • Recently, the development of new structural model in fixed partial denture system is required to be started from the conceptual design with low cost, high performance and quality. In this point, a FEM based design of partial denture is used to investigate stress distribution on the durable shape. In this paper, the structural performances of partial dentures were analyzed under three biting forces. The periodontal embedding model is introduced on behalf of the detailed supporting tissue, which is composed of dentin, cortical bone, cancellous bone and periodontal ligament. Using topology optimization, the optimal reinforcement layout of connector was obtained and the detail shape in the fixed partial denture was designed.

Strengthening effect of resin denture base by glass fiber reinforcement addition (유리섬유 보강재 첨가에 따른 레진 의치상의 강화효과)

  • Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hea-Young;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Purpose: The aim of this study was analyzed by comparing the effect of glass fiber reinforcement addition on the strength of resin denture base. It was intended to provide a reference data useful for clinical application. Methods: The test specimens (length $64.0{\pm}0.1mm$, width $10.0{\pm}0.1mm$, thickness $1.0{\pm}0.1mm$, $1.5{\pm}0.1mm$, and $2.0{\pm}0.1mm$ respectively) were made. In the experimental groups resin denture base reinforced with glass fiber were fabricated. In the control groups resin denture base were fabricated by conventional method. After specimen fabrication was completed, transverse test was performed using a universal testing machine. Results: The transverse strength value in CON group was $83.08{\pm}9.07MPa$ for 1.0 mm, which ranked the highest in value. On the other hand, the value was $56.07{\pm}5.15MPa$ for 2.0mm, which ranked the lowest in value. And CON+SES group was $119.80{\pm}30.70MPa$ for 1.0mm, which ranked the highest in value. On the other hand, the value was $84.00{\pm}7.97MPa$ for 2.0mm, which ranked the lowest in value. Also, the flexural modulus value in CON group was $2,983.10{\pm}506.92MPa$ for 1.0mm, which ranked the highest in value. On the other hand, the value was $1,257.64{\pm}230.48MPa$ for 2.0mm, which ranked the lowest in value. And CON+SES group was $4,679.41{\pm}1578.29MPa$ for 1.0mm, which ranked the highest in value. On the other hand, the value was $2,512.36{\pm}527.09MPa$ for 2.0mm, which ranked the lowest in value. Conclusion: The reinforced glass fiber increased the strength of resin denture base, effected to reduce the thickness of resin denture base.

Effect of fiber glass on the physical properties of denture base resins (화이버 글라스가 의치상 레진의 기계적 특성에 미치는 영향)

  • Park, Yeon-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.35 no.2
    • /
    • pp.97-103
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the effect of addition of fiber glass on the physical properties of silanized fiber mesh and non silanized mesh of denture base resins. Methods: The denture base resins were used in this study heat curing acrylic resins(Vertex Rs, Lucitone 199, $20{\times}80mm$) and fiber glass(SES, Green B&D co., Ltd, $20{\times}80mm$) were used as reinforcement. The specimens were stored in distilled water at $37{\pm}2^{\circ}C$ for 72 hours before test. Bending strength and tensile strength were measured by an universal testing machine(Instron 4301, Instron Corp.). Penetration distribution on fiber was observed by scanning electron microscopy(JSM 840A, Jeol Ltd). Results: The bending strength and modulus were increased by 30% after adding fiber glass on denture base resins. Tensile strength showed significant increasing by adding fiber glass on denture base resins. Conclusion: In this study, Addition of silanized fiber in denture base resins were improved physical properties. we confirmed the fiber glass possibility of the replacement about conventional materials.

Effect of location of glass fiber pre-impregnated with light-curing resin on the fracture strength and fracture modes of a maxillary complete denture (광중합형 레진에 함침시킨 유리섬유의 위치가 상악 총의치의 파절강도와 파절양상에 미치는 영향)

  • Yoo, Hyun-Sang;Sung, Su-Jin;Jo, Jae-Young;Lee, Do-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • Purpose: This study evaluated the effect of glass fiber pre-impregnated with light-curing resin on the fracture strength and fracture modes of a maxillary complete denture. Materials and methods: Maxillary acrylic resin complete dentures reinforced with glass fiber pre-impregnated with light-curing resin (SES MESH, INNO Dental Co., Yeoncheongun, Korea) and without reinforcement were tested. The reinforcing material was embedded in the denture base resin and placed different regions (Control, without reinforcement; Group A, center of anterior ridge; Group B, rugae area; Group C, center of palate; Group D, full coverage of denture base). The fracture strength and fracture modes of a maxillary complete denture were tested using Instron test machine (Instron Co., Canton, MA, USA) at a 5.0 mm/min crosshead speed. The flexure load was applied to center of denture with a 20 mm diameter ball attachment. When fracture occurred, the fracture mode was classified based on fracture lines. The data were analyzed with one-way ANOVA at the significance level of 0.05. Results: There were non-significant differences (P>.05) in the fracture strength among test groups. Group A showed anteroposterior fracture and posterior fracture mainly, group B, C and control group showed partial fracture on center area mostly. Most specimen of group D showed posterior fracture. Conclusion: The location and presence of the fiber reinforcement did not affect the fracture strength of maxillary complete denture. However, reinforcing acrylic resin denture with glass fiber has a tendency to suppress the crack.

Effect of Fiber Type and Combination on the Reinforcement of Heat Polymerized Denture Base Resin (섬유의 종류와 조합이 열중합 의치상 레진의 강화에 미치는 영향)

  • Yu, Sang-Hui;Kim, Young-Im
    • Journal of dental hygiene science
    • /
    • v.10 no.6
    • /
    • pp.445-450
    • /
    • 2010
  • The aim of this study was to evaluate the effect according to the fiber type and combination on the reinforcement of heat-polymerized denture base resin. The heat-polymerized resin(Vertex RS, Dentimax, Netherlands) was used in this study. Glass fiber(GL; ER 270FW, Hankuk Fiber Glass, Korea), polyaromatic polyamide fiber(PA; aramid; Kevlar-49, Dupont, U.S.A.) and ultra high molecular weight polyethylene fiber(PE, polyethylene; P.E, Dong Yang Rope, Korea) were used to reinforce the denture base resin specimens. The final size of test specimen was $64mm{\times}10mm{\times}3.3mm$. The specimens of each group were stored in distilled water at $37^{\circ}C$ for 50 hours before measurement. The flexural strength and flexural modulus were measured by an universal testing machine(Z020, Zwick, Germany) at a crosshead speed of 5 mm/min in a three-point bending mode. In this study, all fibers showed reinforcing effects on denture base resin(p<0.05). In terms of flexural strength and flexural modulus, glass fiber 5.3 vol.% showed most effective reinforcing effect on heat polymerized denture base resin. For flexural modulus, PA/GL was the highest in denture base resin specimen for hybrid FRC using two combination (p<0.05). Glass fiber 5.3 vol.% and PA/GL are considered to be applied effectively in reinforcing the heat polymerized denture base resin.

Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading

  • Im, So-Min;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.22-30
    • /
    • 2017
  • PURPOSE. The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.