• Title/Summary/Keyword: Reset

Search Result 533, Processing Time 0.023 seconds

A New Driving Waveform for the Dark Room Contrast Ratio and Reduction of the Reset Period in AC Plasma Display Panel

  • Lee, In-Moo;Kim, Joon-Yub
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1183-1186
    • /
    • 2005
  • A new reset method for high contrast ratio and reduction of the reset time is presented. In this new reset method, except the first subfield, a new reset pulse with only ramp-up period is adopted. In this reset method, from the third subfield, the background luminance generated during the reset period is theoretically zero until the first subfield of the following frame. Employing the new reset method, the dark room contrast ratio improved to 3084.7:1 from 189.1:1 of the conventional reset method. The new reset method reduced the required time for reset per subfield to 160us except the first subfield.

  • PDF

The new reset pulse used negative ramp slope for improving the addressing characteristic in ac PDP (ac PDP에서 Addressing 특성개선을 위한 Negative Ramp Slope이 적용된 Reset Pulse에 관한 연구)

  • Choi, Hye-Rim;Jung, Sun-Wook;Kang, Jung-Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.2 s.15
    • /
    • pp.11-14
    • /
    • 2006
  • A new reset waveform with negative ramp pulse is proposed. Conventional reset waveform applied to the commercial PDP uses a positive ramp pulse. The reset waveforms, especially focused on ramp area, were examined with 2 dimensional fluid code. The proposed negative reset waveform showed much lower ignition voltage ($\sim$70V) as compared with the conventional reset waveform. When the negative ramp pulse was applied, all of the positive-charged ions are collected on the scan electrode. It is found that the ignition voltage of reset discharge due to the negative ramp pulse became lower than that of positive ramp discharge.

  • PDF

ac PDP에서 Addressing 특성개선을 위한 Negative Ramp Slope이 적용된 Reset Pulse에 관한 연구

  • Choe Hye-Rim;Jeong Seon-Uk;Gang Jeong-Won
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.05a
    • /
    • pp.139-144
    • /
    • 2006
  • 일반적인 PDP 에 적용된 ADS 방식에서 Reset 파형은 ON/OFF Cell 을 초기화 시켜주고 Wall charge를 쌓아줌으로써 낮은 Address 전압으로도 구동을 가능하게 해준다. 기존의 Reset 파형은 Positive ramp pulse를 이용하여 구현하고 있으나 본 논문은 Negative ramp pulse가 적용된 새로운 Reset 파형을 제안하고자 한다. 2-Dimensional fluid simulation code를 이용하여 Ramp부분에 초점을 맞춰 Reset파형을 분석했으며 제안된 Negative ramp reset 파형은 기존의 Positive ramp reset 파형보다 70V가 낮은 전압에서 방전이 발생되는 것을 확인했다. Negative ramp pulse를 적용됐을 경우, Positive ion들이 모두 Negative ramp pulse가 인가된 Scan전극으로 모이는 현상 때문에 기존 Reset파형에 의한 방전일 때보다 낮은 전압에서의 초기방전을 발생시키므로 Reset에 소요되는 시간과 전압을 감소시킬 수 있다.

  • PDF

A Wire-overhead-free Reset Propagation Scheme for Millimeter-scale Sensor Systems

  • Lee, Inhee;Bang, Suyoung;Kim, Yejoong;Kim, Gyouho;Sylvester, Dennis;Blaauw, David;Lee, Yoonmyung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.4
    • /
    • pp.524-533
    • /
    • 2017
  • This paper presents a novel reset scheme for mm-scale sensing systems with stringent volume and area constraints. In such systems, multi-layer structure is required to maximize the silicon area per volume and minimize the system size. The multi-layer structure requires wirebonding connections for power delivery and communication among layers, but the area overhead for wirebonding pads can be significant. The proposed reset scheme exploits already existing power wires and thus does not require additional wires for system-wide reset operation. To implement the proposed reset scheme, a power management unit is designed to impose reset condition, and a reset detector is designed to interpret the reset condition indicated by the power wires. The reset detector uses a coupling capacitor for the initial power-up and a feedback path to hold the developed supply voltage. The prototype reset detector is fabricated in a $180-{\mu}m$ CMOS process, and the measurement results with the prototype mm-scale system confirmed robust reset operation over a wide range of temperatures and voltages.

Short and Effective Reset Method for AC PDPs

  • Kim, Joon-Yub;Lee, In-Moo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.241-245
    • /
    • 2006
  • Reset is necessary for effective addressing in AC PDPs, but reset takes considerable time and produces background luminance. A reset method that takes less time but is effective for addressing is presented. Furthermore, this reset method produces almost negligible background luminance.

  • PDF

New TCP Reset Attack (새로운 TCP Reset 공격방법)

  • Kim, A-Young;Kim, Eun-Gi
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.605-607
    • /
    • 2012
  • In this paper, we propose another TCP Reset Attack. In the process of TCP's 3-way handshake, the receiver in the listen state receives segment including abnormal ACK number, then sends Reset to the sender (RFC 792). In this study, Attacker who monitors sender's packets sent in TCP initial connection sends segment including abnormal ACK number to the receiver before the sender sends normal ACK segment. The receiver received abnormal ACK number sends Reset to the sender. As a result, TCP connection is not established between the sender and the receiver.

  • PDF

A new ramp reset waveform for reducing reset period using address pulse of AC-PDP

  • Kim, Gun-Su;Choi, Hoon-Young;Lee, Seok-Hyun;Kim, Jun-Hyoung;Mim, Byoung-Kuk
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.609-612
    • /
    • 2002
  • A new reset waveform is proposed for reducing the reset period. A square pulse is applied to the address electrode while reset pulse ramps and before a discharge between the sustain electrodes occurs. The square pulse induces a discharge between the address electrode and the X electrode, and the induced wall charge is opposite to the applied ramp pulse. Thus, the next discharge between the sustain electrodes becomes weaker. The weaker discharge lowers background luminance and improves contrast ratio. Thus, the new reset waveform can reduce ramp up time in the ramp reset waveform The experimental results show that the ramp up time can be reduced by about 90% compared with the conventional ramp reset waveform.

  • PDF

Reset Waveform Generation Circuit Adapting To Temperature Change (온도 적응형 PDP RESET 파형 발생회로의 개발)

  • Shin Min-Ho;Kim Cheul-U
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.587-591
    • /
    • 2005
  • Driving Waveform of AC PDP in reset periode is increased and decreased with constant slope to improve dark room contrast ratio and image quality. But the slope and magnitude of ramp waveform are related to strong and weak discharge with temperature change in AC PDP. So this paper proposes a methods of changing the slope and magnitude of ramp waveform during reset periode according to temperature change in AC PDP. Experimental variable factors ire chosen to setup slope, setdown slope, and -Vy voltage magnitude in Y sustain electrode. The proposed methods are expected to compensate for effect of the temperature change, causing misfiring in high and low temprature, with varing the slope and magnitude of ramp voltage during reset period and improve image quality.

The Discharge Characteristic Analysis of a Ramp Reset Waveform Using a 2-Dimensional Numerical Simulation in AC PDP (AC PDP에서 2차원 수치해석을 이용한 Ramp Reset 구동파형에 따른 방전 특성 분석)

  • Park Suk-Jae;Choi Hoon-Young;Seo Jeong-Hyun;Lee Seok-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.12
    • /
    • pp.606-615
    • /
    • 2004
  • The discharge characteristics of a ramp reset waveform in the alternating current plasma display panel(ac PDP) were studied using a 2-dimensional numerical simulation. We analyzed the wall charge variation during the reset discharge, address discharge and sustain discharge adopting a ramp reset waveform. Then we investigated the principal parameters for a successful discharge. In this paper, we suggest a new parameter, printing particles' density and its effects on the stability of the ramp discharge. The maximum current flows of the three electrodes during the ramp reset period were decreased with the increase in the priming particles's density which was explained with the wall charge characteristics and the current flow characteristics obtained by a 2-D simulation.

A Modified Ramp Reset Waveform for High Contrast Ratio in AC PDPs

  • Kim, Jae-Sung;Yang, Jin-Ho;Ha, Chang-Hoon;Whang, Ki-Woong
    • Journal of Information Display
    • /
    • v.3 no.4
    • /
    • pp.13-18
    • /
    • 2002
  • In general, the background light that is produced during the reset period deteriorates the dark room contrast ratio in AC PDP. In this paper, we propose a modified ramp reset pulse that can reduce the background light to an imperceptible level. In the new reset waveform, the discharges between the scan and sustain electrodes are minimized by applying a positive bias voltage to the sustain electrode and only the weak discharges between the scan and address electrodes are found to occur during the reset period. We also adopted the MgO coated phosphor layer to improve the address voltage margin that was reduced when the bias voltage in the modified ramp reset waveform was applied. As a result, the address voltage margin of 45 V which is the same level of the conventional method was ortained and the dark room contrast ratio was improved up to 7500 : 1.