• 제목/요약/키워드: Resonance

검색결과 11,043건 처리시간 0.033초

주파수 유연화 운영에 따른 발전기 축 비틀림에 관한 연구 (A Study on the Subsynchronous Resonance by Flexible Frequency Operation)

  • 조윤성
    • 조명전기설비학회논문지
    • /
    • 제29권4호
    • /
    • pp.62-68
    • /
    • 2015
  • Subsynchronous Resonance is a condition where the electrical power systems composed of generator and transmission line exchange energy with mechanical turbine-generator system at the frequency of the combined below the subsynchronous frequency. Therefore, the frequency of power systems should be associated with the subsynchronous resonance. This paper describes subsynchronous resonance by flexible frequency operation. It focuses on the characteristics and behavior of subsynchronous resonance. The subsynchronous resonance is being conducted by real-time digital simulator and the IEEE benchmark model for subsynchronous resonance have been utilized for the test systems.

하소온도가 BaTiO3 세라믹의 Kp와 공진특성에 미치는 영향 (Effects of Calcining Temperature on Planar Coupling Factor and Resonance Charcteristics of BaTiO3)

  • 정수태;조상희
    • 한국세라믹학회지
    • /
    • 제23권6호
    • /
    • pp.66-70
    • /
    • 1986
  • The calcining temperature ranging from 900$^{\circ}C$ to 1300$^{\circ}C$ affected on the planar coupling factor and resonance characteristics of BaTiO3 ceramics doped with 0.2 wt% MnO2 have been investigated. Dielectric constant planar coupling factor and anti-resonance frequency of the sample increased with the calcining temperature up to 1,200$^{\circ}C$ and decreased above that temperature but the resonance frequency decreased slightly with the increasing calcining temperature. The planar coupling factor and anti-resonance frequency increased with the sintered density and dielectric constant while the resonance frequency was almost constant. The resonance and anti-resonance frequency increased with the sample temperature.

  • PDF

Resonance Phenomenon and Its Effects of Laser Texture Disk

  • Choa, Sung-Hoon;Wang, Geng
    • Journal of Mechanical Science and Technology
    • /
    • 제14권7호
    • /
    • pp.744-751
    • /
    • 2000
  • To achieve lower flying height for high areal recording density, the laser zone texturing of the disk needs to be designed to reduce glide height. One problem of the laser bump design is that the regular laser bump pattern often produces glide resonance phenomenon, which leads to failure of the glide height test. However, it was found in this study that glide resonance is an intrinsic problem of the glide head used and resonance phenomenon depends on the type of the head slider, that is, the natural frequency of the slider body. Therefore, higher glide height or glide failure caused by glide resonance does not lead to head/media interface problem in the real drive operating conditions in which the data head is used. Pseudo-random bump pattern greatly reduces the glide resonance. Smaller bump pitch will also help to reduce the glide resonance. However, as bump spacing becomes smaller, glide height will be increased due to increased air pressure developed around the bumps. Lowering bump height is the most effect way to reduce glide avalanche.

  • PDF

$^{19}F$ MR Imaging of 5-FU Metabolism in Mice

  • Chaejoon Cheong;Lee, Seung-C.;Jae-G. Seo;Kim, Sung W.;Lee, Chulhyun;Kim, Chul S.;Taegyun Yang
    • 한국자기공명학회논문지
    • /
    • 제5권2호
    • /
    • pp.110-117
    • /
    • 2001
  • $^{19}$ F imaging of mice was carried out. For $^{19}$ F imaging, 5-flouro-uracil (5-FU) was injected into a mouse and in vivo detection of the catabolism of 5-FU to a-fluoro-P-alanine (FBAL) was carried out. The chemical shift selective (CHESS) imaging technique was employed. The 19F spectra and images give temporal and spatial information of the metabolism for 5-FU in mice.

  • PDF

핀-튜브군에서 배플 길이에 따른 음향공진 (Acoustic resonance by length of acoustic baffle at Finned Tube bank)

  • 방경보;류제욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.98-103
    • /
    • 2003
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a HRSG. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At this tube bank, dominant frequencies of vibration in this system were 43.5, 67.5㎐. The 3$\^$rd/ acoustic natural frequency calculated was 68.5㎐. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}$20%, acoustic resonance could occur. In this system, in order to prevent acoustic resonance, acoustic baffle was installed in the tube bank before operating. But acoustic resonance occurred. So, we evaluate the effect of acoustic mode due to baffle extension length. After investigating, we did revise acoustic baffle to eliminate acoustic resonance effectively.

  • PDF

고조파 공진 억제를 위한 완충부하 투입량 분석에 관한 연구 (A Study on the Analysis of Damping Loads to Prevent Harmonic Resonance)

  • 임찬호;이경섭;유원근;이흥재
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.262-266
    • /
    • 2010
  • During the restoration process of primary restorative transmission system, the over voltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This over voltage is caused by harmonic resonance and can be prevented by damping loads that are connected before restoration process of primary restorative transmission system. But it is very difficult to predict the occurrence possibility of the harmonic resonance previously. This paper analyzes the relationship between the harmonic resonance and the amount of damping loads to prevent the harmonic resonance. This paper calculates the minimum amount of damping loads to prevent harmonic resonance while changing the length of primary restorative transmission line. And this paper confirmed that the amount of damping loads is not proportional to length of transmission line. The result of this paper will be used as important experiment data to predict the occurrence possibility of harmonic resonance previously.

Analysis on the cascade high power piezoelectric ultrasonic transducers

  • Lin, Shuyu;Xu, Jie
    • Smart Structures and Systems
    • /
    • 제21권2호
    • /
    • pp.151-161
    • /
    • 2018
  • A new type of cascade sandwiched piezoelectric ultrasonic transducer is presented and studied. The cascade transducer is composed of two traditional longitudinally sandwiched piezoelectric transducers, which are connected together in series mechanically and in parallel electrically. Based on the analytical method, the electromechanical equivalent circuit of the cascade transducer is derived and the resonance/anti-resonance frequency equations are obtained. The impedance characteristics and the vibrational modes of the transducer are analyzed. By means of numerical method, the dependency of the resonance/anti-resonance frequency and the effective electromechanical coupling coefficient on the geometrical dimensions of the cascade transducer are studied and some interesting conclusions are obtained. Two prototypes of the cascade transducers are designed and made; the resonance/anti-resonance frequency is measured. It is shown that the analytical resonance/anti-resonance frequencies are in good agreement with the experimental results. It is expected that this kind of cascade transducer can be used in large power and high intensity ultrasonic applications, such as ultrasonic liquid processing, ultrasonic metal machining and ultrasonic welding and soldering.

Accessory Belly of the Piriformis Muscle as a Cause of Piriformis Syndrome: a Case Report with Magnetic Resonance Imaging and Magnetic Resonance Neurography Imaging Findings

  • Kim, Hae-Jung;Lee, So-Yeon;Park, Hee-Jin;Kim, Kun-Woo;Lee, Young-Tak
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권2호
    • /
    • pp.142-147
    • /
    • 2019
  • Piriformis syndrome caused by an accessory belly of the piriformis muscle is very rare. Only a few cases have been reported. Here, we report a case of piriformis syndrome resulting from an extremely rare type of accessory belly of the piriformis muscle originated at the proximal third portion of the main piriformis muscle and attached separately to the greater trochanter inferior to the insertion of the main piriformis muscle. A definitive diagnosis of piriformis syndrome was made based on magnetic resonance imaging and magnetic resonance neurography findings that were consistent with results of nerve conduction study and needle electromyography.

성덕대왕신종의 명동과 간극의 공명조건 (Resonance Condition of the Resonance Cavity and Air Gap in the Sacred Bell of the Great King Seongdeok)

  • 김석현;정원태;강연준
    • 한국음향학회지
    • /
    • 제30권4호
    • /
    • pp.223-230
    • /
    • 2011
  • 한국종은 지면으로부터 일정한 간극을 두고 매달리며, 종 아래에 명동이라고 불리는 독특한 음향학적 요소를 갖고 있다. 간극과 명동의 적절한 설계는 공명효과에 의하여 종소리를 극적으로 증폭시킨다. 종체의 내부공동과 간극, 그리고 명동으로 구성된 음향공동계는 공명주파수와 모드를 갖는데, 공명주파수가 종체의 고유진동수에 일치하게 되면, 그 주파수성분이 크게 증폭된다. 이 연구는 성덕대왕신종을 대상으로 간극효과를 고려한 명동의 공명조건을 처음으로 제시한다. 공명조건을 구하기 위하여 신종의 실제 치수를 사용하여 SYSNOISE를 이용한 경계요소해석을 수행하였다. 또한, 계절에 따른 기온의 차이가 공명조건에 어떠한 영향을 미치는가를 규명하고, 가변형 명동의 개념을 제시함으로써, 현장에서 온도차를 보정하여 정확한 공명조건을 구현시킬 수 있는 방안을 제공한다.