• Title/Summary/Keyword: Retractable Roof

Search Result 39, Processing Time 0.023 seconds

Case Analysis of Open-Close Time of Retractable Building Structure and Design Wind Speed (개폐식 건축물의 개폐 시간 및 설계 풍속 사례 분석)

  • Song, Jin-Young;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.79-87
    • /
    • 2017
  • The retractable roof structure is used in various fields and it is classified for steel retractable system and soft retractable system. For the domestic industry, it is in the initial phase now and the demand of the retractable roof structure is expected to increase in the future. Therefore, this paper is classified for steel retractable system and soft retractable system from the retractable roof structures in overseas to survey and analyze the cases of wind velocity on retractable roof structure in Japan that uses the same wind velocity criteria like Korea regarding the open-close time and average open-close time for retractable roof area.

Seismic Response Control of Retractable-roof Spatial Structure Using Smart TMD (스마트 TMD를 이용한 개폐식 대공간 구조물의 지진응답제어)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.91-100
    • /
    • 2016
  • A retractable-roof spatial structure is frequently used for a stadium and sports hall. A retractable-roof spatial structure allows natural lighting, ventilation, optimal conditions for grass growth with opened roof. It can also protects users against various weather conditions and give optimal circumstances for different activities. Dynamic characteristics of a retractable-roof spatial structure is changed based on opened or closed roof condition. A tuned mass damper (TMD) is widely used to reduce seismic responses of a structure. When a TMD is properly tuned, its control performance is excellent. Opened or closed roof condition causes dynamic characteristics variation of a retractable-roof spatial structure resulting in off-tuning. This dynamic characteristics variation was investigated. Control performance of a passive TMD and a smart TMD were evaluated under off-tuning condition.

Vibration Analysis of Space Structure with Retractable Roof (개폐식 지붕구조의 움직임에 대한 공간구조물의 진동해석)

  • Kim, Gee-Cheol;Kang, Joo-Won;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.113-120
    • /
    • 2011
  • Retractable roof system is one of the special feature in stadium or complex structure. And this retractable roof system makes possible to use spacial structure all-weather. This retractable roof system is able to classified into overlapping, parallel movement and folding system. Moving load, impact load, inertial or braking loads, these dynamic loads induced by movements of retractable roof system. So it is necessary to analysis of spacial structures are subjected to these dynamic loads. Dynamic loads that are induced by the retractable roof movements can be applied to moving mass method or moving force method. But, moving force method is appropriate because the retractable roof movements is slow relatively. In this paper, new application method of moving forces induced by the retractable roof movements is proposed. And vibration analysis of spacial structures are executed by using the proposed method. This proposed equivalent moving force can be easily applied to spacial structure that is subjected to dynamic loads induced by movement of the retractable roof system.

Mechanical Characteristics of Retractable Radial Cable Roof Systems (개폐식 방사형 케이블 지붕 시스템의 역학적 특성)

  • Park, Kang-Geun;Lee, Dong-Woo;Choe, Dong-Il
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.21-32
    • /
    • 2017
  • The objective of this study is to analysis the mechanical characteristics on the geometric nonlinear behavior of radial cable roof systems for long span retractable cable roof structures. The retractable roof is designed as a full control system to overcome extreme outdoor environments such as extreme hot or cold weather, strong wind or sunlight, and the cable roof greatly can reduce roof weight compared to other rigid structural system. A retractable cable roof system is a type of structures in which the part of entire roof can be opened and closed. The radial cable roof is an effective structural system for large span retractable roofs, the outer perimeter of the roof is a fixed membrane roof and the middle part is a roof that can be opened and closed. The double arrangement cables of a radial cable truss roof system with reverse curvature works more effectively as a load bearing cables, the cable system can carry vertical load in up and downward direction. In this paper, to analyze the mechanical characteristics of a radial cable roof system with central posts, the authors will investigate the tensile forces of bearing cables, stabilized cables, ring cables, and the deflection of roof according to the height of the post or hub that affects the sag ratio of cable truss. The tensile forces of the cables and the deflection of the roof are compared for the cases when the retractable roof is closed and opened.

A Case Study of Retraction Controlled Wind Velocity on the Steel Retractable Roof of Large Span (강성개폐식 대공간 지붕의 개폐 관리풍속 사례 분석)

  • Song, Jin-Young;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.1
    • /
    • pp.93-100
    • /
    • 2018
  • The retractable roof structures have actions of various types of loads and external forces depending on the retraction and operation conditions of the roof in terms of efficiency of control and maintenance as the aspect of structural plan. In particular, there is a need for studies on the establishment of retraction controlled wind velocity to maintain the stable control and usability of roof structure against strong winds or sudden gusts during the retraction of the roof. In this paper, it was intended to provide basic materials for the development of guidelines on the operation and maintenance of domestic retractable buildings with large space by analyzing the factors affecting the retraction controlled wind velocity for the overseas stadiums with the large spatial retractable roof structures where the sliding system was applied on the steel retractable systems. As a result, the controlled wind velocity tends to decrease as the retractable roof area increases. On the other hand, the controlled wind velocity tends to increase as the retraction time increases. In addition, in the space-grid roof structures, the spherical roof structures type showed the average controlled wind velocity of 10m/sec lower than that of 17.3m/sec for curved-roof structure type, and in the curved-roof structure type, the truss roof structure showed the average controlled wind velocity of 8.9m/sec which is lower than that of 17.3m/sec for the space for the space-grid roof structure.

Design Method Development of Smart TMD for Retractable-Roof Spatial Structure (개폐식 대공간 구조물을 위한 스마트 TMD 설계기법 개발)

  • Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.3
    • /
    • pp.107-115
    • /
    • 2017
  • In this paper, a structural design method of a smart tuned mass damper (TMD) for a retractable-roof spatial structure under earthquake excitation was proposed. For this purpose, a retractable-roof spatial structure was simplified to a single degree of freedom (SDOF) model. Dynamic characteristics of a retractable-roof spatial structure is changed based on opened or closed roof condition. This condition was considered in the numerical simulation. A magnetorheological (MR) damper was used to compose a smart TMD and a displacement based ground-hook control algorithm was used to control the smart TMD. The control effectiveness of a smart TMD under harmonic and earthquake excitation were evaluated in comparison with a conventional passive TMD. The vibration control robustness of a smart TMD and a passive TMD were compared along with the variation of natural period of a simplified structure. Dynamic responses of a smart TMD and passive TMD under resonant harmonic excitation and earthquake load were compared by varying mass ratio of TMD to total mass of the simplified structure. The design procedure proposed in this study is expected to be used for preliminary design of a smart TMD for a retractable-roof spatial structure.

A large Retractable Roof Structure in the World (세계의 대형 개폐식 지붕구조)

  • Par, Sun-Woo;Choi, Chui-Kyoung
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.227-231
    • /
    • 2008
  • There are many retractable roof structures in the world. Retractable roofs will be classified by various factors and user, for example span length, moving mechanism, opening system, roof material and utility in over 100 examples. Therefore I will present considerations in architectural planning and structural design.

  • PDF

Development of Video Transmission Device for Monitoring of a Cable-Based Retractable Roof (케이블-기반 개폐식 지붕의 모니터링을 위한 영상 전송 장치 개발)

  • Ahn, Soohong;Shon, Sudeok;Lee, Seungjae;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.4
    • /
    • pp.103-110
    • /
    • 2019
  • The cable-based retractable membrane roof makes it impossible to maintain its shape and stiffness during driving process, unlike the hard-type retractable roof. Consequently, monitoring using a relatively simple wireless video transmission device is required. However, since video data has a bigger transmission rating than other monitoring data in terms of the structure velocity or acceleration, there is a need to develop transmission device that is easy to install and entails low maintenance cost. This paper studies on a real-time video transmission system for monitoring the cable-based retractable membrane roof while driving. A video transfer software, using the mobile network, is designed and the embedded system is constructed. Ultimately, the data transmission server is tested. Connecting a trolley to the system allows testing of the validity and efficiency of the developed system through the video data transmitted in the driving process. Result of the test shows that the developed system enables multi-device data transfer with monitoring via the mobile network.

Comparison of Wind Pressure Coefficient and Wind Load Standard for Cladding in a Retractable Dome Roof by Wind Tunnel Test (풍동 실험을 통한 개폐식 돔 지붕의 외장재용 풍압 계수와 풍하중 기준 비교)

  • Cheon, Dong-jin;Kim, Yong-Chul;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.3
    • /
    • pp.125-132
    • /
    • 2018
  • The biggest impact on the cladding design of buildings is wind loads. Wind tunnel tests were conducted to examine the applicability of current wind load standards about membrane retractable roof spatial structure. A dome model with a circular shape that is retractable to the center of the dome was made (Opening ratio = 0, 10, 30, 50). In addition, height adjustable turntables were made and tested with five patterns with H/D = 0.1, 0.2, 0.3, 0.4 and 0.5. The maximum wind pressure coefficient and the minimum wind pressure coefficient for the cladding were analyzed and the experimental wind pressure coefficient were compared with the current wind load standards, KBC2016 and AIJ-RLB(2015). The experimental value and the reference value of the enclosed roof were very similar and showed possibility of application, but opened roof case was found that the reference value was underestimated.

Trolley Adaptability of Membrane Retractable Roof Under Vertical Load Considering Friction of Various Materials (다양한 재료의 마찰계수를 고려한 중소규모 연성 개폐식 트롤리의 수직하중에 대한 적용성 평가)

  • Kim, Yun-Jin;Lee, Seung-Jae;Lee, Yu-Han;Hwang, Kyung-Ju
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.83-89
    • /
    • 2016
  • Middle size of membrane retractable roof is under 25m span which consists of various moving systems. Trolley is the system that leads the membrane to parking place, transferring the load from the membrane to structural cable. When membrane closes roof completely, thus, structural behavior of trolley, which may contain various material with different friction coefficients, should be investigated by vertical load. Nummerical simulation of trolley prototypes, in this research, was performed by incrementation of vertical load. Consequently, this paper studied proper friction characteristics and provided the effective inner materials of trolley.