• 제목/요약/키워드: Root canal sealer

검색결과 122건 처리시간 0.027초

생체외 실험을 이용한 근관충전용 Sealer의 세포독성에 관한 연구 (A STUDY OF THE CYTOTOXICITY OF ROOT CANAL SEALER IN VITRO)

  • 이상탁;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.62-84
    • /
    • 1991
  • The purpose of this study was to evaluate the cytotoxicity of four root canal sealers(Tubliseal, AH26, Apatite Root Canal Sealer I, Apatite Root Canal Sealer II) in Vitro. The root canal sealers were mixed and filled in molds which were $14{\times}1.25mm$ in diameter, in height to use for cell counting and agar overlary method, and $7{\times}1.25mm$ for millipore filter method and set for 7 days to use for experiment. Silicone and copper plate were used for negative and positive control respectively. Using the culture of L929 fibroblast, total cell number and vital cell number were counted and the ratio of vital cell number to total cell number was calculated on 2 nd, 4 th, 6 th experimental day, and the change of cell membrane permeability was tested by agar overlay method, and the succinate dehydrogenase activity was tested by millipore filter method. The obtained results were as follows. 1. In ail experimental groups, the mitotic activity of fibroblast was reduced when compared with that of negative control group, so ail experimental groups showed cytotoxicity. Apatite Root Canal Sealer I group exhibited mild cytotoxicity, and Tubliseal, AH26, Apatite Root Cenal Sealer II groups exhibited severe cytotoxicity. 2. In the test of the change of cell membrane permeability by agar overlay method, all experimental groups showed cytotoxicity. AH26 group exhibited mild cytotoxicity, and Apatite Root Canal Sealer I group exhibited moderate cytotoxicity, and Tubliseal and Apatite Root Canal Sealer II group exhibited severe cytotoxicity. 3. In the test of SDH activity by millipore filter method, there was no cytotoxicity in Apatite Root Canal Sealer I and Apatite Root Canal Sealer II group, but Tubliseal and AH26 group showed mild cytotoxicity.

  • PDF

Micro-computed tomographic evaluation of a new system for root canal filling using calcium silicate-based root canal sealers

  • Tanomaru-Filho, Mario;Torres, Fernanda Ferrari Esteves;Pinto, Jader Camilo;Santos-Junior, Airton Oliveira;Tavares, Karina Ines Medina Carita;Guerreiro-Tanomaru, Juliane Maria
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.34.1-34.7
    • /
    • 2020
  • Objectives: This study evaluated by using micro-computed tomography (micro-CT) the filling ability and sealer apical extrusion promoted by a new Sealer Injection System (SIS; Angelus) with side openings needle, in comparison with the conventional injection system, associated with a new ready-to-use calcium silicate-based sealer (Bio-C Sealer). Materials and Methods: Acrylic resin models containing a main curved artificial canal and 3 simulated lateral canals in apical, middle and cervical thirds were used. The main root canals were prepared using a rotary system up to size 35.05. The canals were filled with Bio-C sealer by using a single cone technique and the conventional delivery system or SIS. Samples were scanned in micro-CT. The percentage of voids throughout the entire extension of the main root canal and in each third of the lateral canals, besides the apical extrusion of the sealer was calculated. Data were submitted to t-test (p < 0.05). Results: There was no difference between both systems in the main root canals filling. Although the volume percentage of voids was similar in the apical and middle thirds of lateral canals, SIS had the greatest filling ability of the cervical third lateral canal. Moreover, the conventional system showed the highest apical extrusion of the sealer. Conclusions: The conventional and SIS obturation systems had an appropriate filling ability of the main root canal. SIS had the best filling of the cervical third of the lateral canals, besides lower sealer apical extrusion, suggesting its clinical indication.

초음파 근관기구를 이용한 근관충전법의 근관폐쇄능에 관한 주사 전자현미경적 연구 (A SCANNING ELECTRON MICROSCOPIC EVALUATION OF THE ROOT CANAL FILLING WITH ULTRASONIC ENDODONTIC INSTRUMENT)

  • 최라영;이인숙
    • Restorative Dentistry and Endodontics
    • /
    • 제15권2호
    • /
    • pp.104-114
    • /
    • 1990
  • The purpose of this study was to evaluate the adaptation of root canal filling material to the dentinal wall of root canal and to compare the sealing ability of the root canal filling materials using ultrasonic endodontic instrument with injection-molded thermoplasticized gutta-percha filling method and lateral condensation method. Fifty fresh human single root exlracted for orthodontic treatment, were randomly selected, and instrumented by step-back technique. And then, the teeth were divided into 5 groups according to each root canal filling methods. In the experimental group 1 and group 2, the root canals were filled with gutta perdia cases using ultrasonic instrument with and without sealer. In the experimental group 3 and 4, using jection-moldeed thermoplasticized gutta-percha method by obtul$^{(R)}$ canals were filled with and without sealer. In the control group, the canals were filled with sealer by lateral candensation. And then, 5 teeth of each group were immersed in black Indian ink, decalcified and cleared. The depth of dye penetration into the root canal were evaluated with stereoscope (Reichert Ltd., USA). Among the 5 teeth remaining in each group, the single longituding grooves were made on the labial and lingual root surfaces and then immersed in the liquid nitrogen to fracture the teeth spontaneously without any distortions of gutta-percha. Each specimens were examined with X-650 Scanning Electron Microscope(Hitachi ltd, Japan) to show the adaptation to the canal wall, void, homogenicity of filling material and location of gutta-percha or sealer in the dentinal tubules of the root canal. The observations were as follows : 1. The experimental group 1 showed smaller mean dye penetration than control group, and showed the penetraton of sealer in the dentinal tubules of apical third of the root canal. 2. The experimental group 2 and group 4 showed the penetration of gutta-percha in the dentinal tubules of root canals. 3. The experimental group 1 and group 3 showed less mean dye penetration than the experimental group 2 and group 4. 4. The experimental group 1 and group 2 showed better adaptation of filling materials than control group.

  • PDF

A comparative evaluation of cytotoxicity of root canal sealers: an in vitro study

  • Badole, Gautam Pyarelal;Warhadpande, Manjusha Madhukar;Meshram, Ganesh Kothiramji;Bahadure, Rakesh Namdeoraoji;Tawani, Shubha Gopal;Tawani, Gopal;Badole, Shital Gautam
    • Restorative Dentistry and Endodontics
    • /
    • 제38권4호
    • /
    • pp.204-209
    • /
    • 2013
  • Objectives: The objective of this in vitro study was to evaluate and compare the cytotoxicity of four different root canal sealers i.e. Apexit Plus (Ivoclar Vivadent), Endomethasone N (Septodont), AH-26 (Dentsply) and Pulpdent Root Canal Sealer (Pulpdent), on a mouse fibroblast cell line (L929). Materials and Methods: Thirty two discs for each sealer (5 mm in diameter and 2 mm in height) were fabricated in Teflon mould. The sealer extraction was made in cell culture medium (Dulbecco's Modified Eagle's Medium, DMEM) using the ratio 1.25 $cm^2/mL$ between the surface of the sealer samples and the volume of medium in a shaker incubator. Extraction of each sealer was obtained at 24 hr, 7th day, 14th day, and one month of interval. These extracts were incubated with L929 cell line and 3-(4,5-dimethylthiazol-2yl)-2,5-diphenyltetrazolium bromide (MTT) assay was done. Two-way ANOVA for interaction effects between sealer and time and Post-hoc multiple comparison using Tukey's test across all the 16 different groups were used for statistical analysis. Results: Apexit Plus root canal sealer was significantly less toxic than other sealers (p < 0.05) and showed higher cellular growth than control. Endomethasone N showed mild cytotoxicity. AH-26 showed severe toxicity which became mild after one month while Pulpdent Root Canal Sealer showed severe to moderate toxicity. Conclusions: Apexit Plus was relatively biocompatible sealer as compared to other three sealers which were cytotoxic at their initial stages, however, they became biocompatible with time.

Biocompatibility and Bioactivity of Four Different Root Canal Sealers in Osteoblastic Cell Line MC3T3-El

  • Jun, Nu-Ri;Lee, Sun-Kyung;Lee, Sang-Im
    • 치위생과학회지
    • /
    • 제21권4호
    • /
    • pp.243-250
    • /
    • 2021
  • Background: Endodontic sealers or their toxic components may become inflamed and lead to delayed wound healing when in direct contact with periapical tissues over an extended period. Moreover, an overfilled sealer can directly interact with adjacent tissues and may cause immediate necrosis or further resorption. Therefore, the treatment outcome conceivably depends on the endodontic sealer's biocompatibility and osteogenic potential. This study aimed to evaluate the cell viability and osteogenic effects of four different sealers in osteoblastic cells. Methods: AH Plus (resin-based sealer), Pulp Canal Sealer EWT (zinc oxide-eugenol sealer), BioRoot RCS (calcium silicate-based sealer), and Well-Root ST (MTA-based calcium silicate sealer) were mixed strictly according to the manufacturer's instructions, and dilutions of sealer extracts (1/2, 1/5 and 1/10) were determined. Cell viability was measured using the water-soluble tetrazolium-8 (WST-8) assay. Differentiation was assessed by alkaline phosphatase (ALP) activity and mineralized nodule formation by Alizarin Red S staining. Results: The cell viability of the extracts derived from the sealers excluding Well-Root ST was concentration dependent, with sealer extracts having the least viability at a 1/2 dilution. At sealer extract dilution of 1/10, the test groups showed the same survival rate as that control group, with the exception of BioRoot RCS. Among all experimental groups, BioRoot RCS showed the highest cell viability after 48 hours. The ALP activity was significantly higher in a concentration-dependent manner. Furthemore, all four materials promoted ALP activity and mineralized nodule formation compared to the control at 1/10 dilutions. Conclusion: This is the first study to highlight the differences in biological activity of these four materials. These results suggest that the composition of root canal sealers appears to alter the form of biocompatibility and osteoblastic differentiation.

근관충전용 실러의 물리적 성질에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES OF ROOT CANAL SEALERS)

  • 장영인;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.142-151
    • /
    • 1995
  • The purpose of this study was to compare and estimate the physical properties of five root canal sealers classified Calciobiotic root canals sealer as calcium hydroxide based sealer, Apatite root sealer type II as calcium phosphate based sealer, AH-26 as resin based sealer, Canals and Pulpdent root canals sealer as zinc oxide eugenol based sealer. The author investigated dimensional change and flow rate of canal sealers, diametral tensile strength and shear bond strength of sealers to dentin to evaluate the physical properties on affect of complete obturation of root canal and performed the total 100 specimens of each 25 sealers under the condition of root temperature according to manufacturer's instructions. All specimens were stored at $37{\pm}1^{\circ}C$ in 100 % relative humidity. A microscope for measurement of micro distance is used for the dimensional change test and evacuation methods using vaccum were used for the flow rate test. The result differed by the storage time measured on the tests of diametral tensile strength and shear bond strength to dentin. The following results were obtained ; 1 On the test of dimensional change, Canals and Pulpdent expanded slightly, AH-26 and Apatite showed the severe shrinkage after 48 hours. 2. AH-26 and Apatite were the excellent with each 24.59mm, 31.19mm after 3 minutes in the aspect of flow property. 3. On the diametral tensile strength, Calciobiotic root canals sealer showed the highest strength with 27.13kg/$cm^2$ after 48 hours, Apatite root sealer type II showed highest strength with 84.57kg/$cm^2$ after 120 hours. 4. On the shear bond strength to dentin, AH-26 was most excellent with 55.73kgf/$cm^2$ after 24 hours and with 134.71kgf/$cm^2$ after 120 hours.

  • PDF

근관충전용(根管充塡用) sealer의 세포독성(細胞毒性)에 관한 연구(硏究) (A STUDY ON THE CYTOTOXICITY OF THE ROOT CANAL SEALERS)

  • 이승종;김영해
    • Restorative Dentistry and Endodontics
    • /
    • 제16권1호
    • /
    • pp.25-40
    • /
    • 1991
  • Four root canal sealers, Apatite Root Sealer I and II composed mainly of hydroxyapatite/tricalciumphosphate, Sealapex containing calcium hydroxide, and Roth Sealer composed of zinc oxide - eugenol were compared on the culture of L929 fibroblasts. MIT (Methyl Thiazole Tetrazolium Bromide) colorimetric technique was used to measure the mitochondrial dehydrogenase activity. Results were as follows: 1. Hydroxyapatite/tricalcium phosphate mixed sealers were significantly less toxic compared with calcium hydroxide and zinc oxide - eugenol type sealers. High pH of the calcium hydroxide sealer and release of eugenol component from the zinc oxide - eugenol type sealer were presumed to be the cause of the toxicity of these two sealers. In no cases, there were more cytoblastic effects in hydroxyapatite/tricalcium phosphate mixed sealers compared to the control groups. 2. In all experimental groups, toxicity was decreased as dilutions were increased. However in zinc oxide-eugenol type sealer the cell activity was weakened for all dilution groups. 3. Regarding the effect of setting time, Apatite I and Sealapex were less toxic as the setting progressed. Apatite II kept constant regardless of the different time ellapsed after setting but Roth sealer revealed significantly higher toxicity for all experimental groups. 4. Comparing two different culture periods of 24 hours and 72 hours, Apatite I showed higher cell activities in longer period(72 hours) while Apatite II did not. Sealapex and Roth sealer, however, showed significantly lower cell activities in longer period.

  • PDF

In vivo study on the biocompatibility of newly developed calcium phosphate-based root canal sealers

  • Kim, Jin-Su;Bae, Kwang-Shik
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.592-593
    • /
    • 2003
  • I. Objectives The purpose of this study was to compare in vivo the biocompatibility of new calcium phosphate-based root canal sealers(CAPSEAL I, CAPSEAL II) with another type of commercially available calcium phosphate sealer (Apatite Root Sealer type I, Apatite Root Sealer type II) and zinc oxide-eugenol-based sealer (Pulp Canal Sealer EWT) after implantaion in rat subcutaneous tissue. II. Materials and Methods 64 Sprague-Dawley rats were used. There were five groups of three animals each for experimental period of 1, 2, 4, and 12 weeks. The teflon tubes, 5mm in length with an inner diameter of 1.5mm, were washed with ethanol and distilled weter and autoclaved.(omitted)

  • PDF

레진 계열 근관봉함재 Adseal의 세포독성에 관한 연구 (CYTOTOXICITY OF RESIN-BASED ROOT CANAL SEALER, ADSEAL)

  • 김희정;백승호;이우철;박한수;배광식
    • Restorative Dentistry and Endodontics
    • /
    • 제29권6호
    • /
    • pp.498-503
    • /
    • 2004
  • The properties of ideal root canal sealers include the ability of sealing the total root canal system and no toxic effects to periradicular tissues. Cytotoxicity test using cell culture is a common screening method for evaluation of the biocompatibility of root canal sealers. The purpose of this study was to investigate the cytotoxic effect of newly developed resin-based sealer (Adseal 1, 2, and 3) comparing with those commercial resin-based sealers (AH26 and AH Plus), ZOE-based sealers (Tubliseal EWT, Pulp Canal Sealer EWT) and calcium hydroxide based sealer (Sealapex), An indirect contact test of cytotoxicity by agar diffusion was performed according to the international standard ISO 10993-5. L929 fibroblast cells were incubated at $37^{\circ}C$ in humidified 5% $CO_2-containing$ air atmosphere. The freshly mixed test materials were inserted into glass rings of internal diameter 5 mm and height 5 mm placed on the agar. After the 24 hrs incubation period, the decolorization zones around the test materials were assessed using an inverted microscope with a calibrated screen. A Decolorization Index was determined for each specimen. Adseal 1. 2, and 3 did not exert any cytotoxic effects, whereas AH26, AH Plus, Tubliseal EWT, Pulp Canal Sealer EWT, and Sealapex produced mild cytotoxicity.

Kerr sealer를 근관충전재(根管充塡材)로 사용시(使用時) 근관폐쇄성(根管閉鏁性)에 관(關)한 실험적(實驗的) 연구(硏究) (EXPERIMENTAL STUDY on SEALING QUALITY OF KERR SEALER AS ROOT CANAL SEALERS)

  • 윤수한
    • Restorative Dentistry and Endodontics
    • /
    • 제6권1호
    • /
    • pp.77-81
    • /
    • 1980
  • The author has studied comparatively the sealing quality of conventional Z.O.E. cement, Kerr sealer and Nogenol sealer by means of penetration of 2% methylene blue solution through the root apex of human teeth in 72 cases as time elapsed. The results were as follows; 1. All the specimens, whose dye immersion time is two days, showed dye penetration of low degree unrelated to the kinds of root canal sealer. 2. Kerr sealer group, like conventional Z.O.E. group, showed dye penetration of high degree related to increased time of immersion in the dye. 3. In Nogenol group, there was slight increase in penetration related to increased time of immersion in the dye. 4. Kerr sealer group showed comparatively lower grade of dye penetration than conventional Z.O.E. and higher than Nogenel sealer.

  • PDF