• Title/Summary/Keyword: Rotational angle

Search Result 434, Processing Time 0.028 seconds

Study for Woehler Fatigue Line of Steel Beam-to-Column Structure (강재 기둥-보 구조물의 피로곡선 연구)

  • Kong Byung-Seung
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.700-705
    • /
    • 2005
  • This study presents a fatigue line with a plastic rotational angle to a great extent of plastic strain of Low-Cycle-fatigue period, such as earthquake, etc. This fatigue line with a plastic rotational angle is measured and analysed more simply in practice rather than Woehler's fatigue line which is developed in stress variation of the structure. It shows that the slope of fatigue line with a plastic rotational angle is equal to that with plastic strain through the experiments by proving the correlation that the plastic strain ratio is directly proportional to the plastic rotational angle in plastic hinge.

  • PDF

A Study on Mandibular Rotational Torque Movement in Subjects with Temporomandibular Joint Sounds (악관절음 환자의 하악 비틀림회전운동에 관한 연구)

  • So, Jong-Seob;Lee, Kyoung-Ho;Chung, Sung-Chang
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.4
    • /
    • pp.455-466
    • /
    • 1999
  • The purpose of this study was to investigate the magnitude of mandibular rotational torque movements in subjects with TMJ sounds, and to analyse correlation between quantitative characteristics of TMJ sounds and mandibular rotational torque movement. Twenty dental college students with TMJ clicking and twenty students without any TMD signs and symptoms were examined by mean of SonoPak and Rotate program of BioPAK system(Bioresearch Inc. MilWaukee, wisconsin, USA) in this study. Mandibular rotational torque movements were recorded and analysed during maximum mouth opening, protrusion, and lateral excursion in frontal and horizontal planes. The obtained results were as follows: 1. On maximum mouth opening, mandibular rotational angle and distance of clicking group were significantly greater than those of control group in frontal plane. (P<0.05). 2. During maximum mouth opening closing, maximum mandibular rotational angle and distance of clicking group were significantly greater than those of control group in frontal plane. (P<0.01). 3. On protrusion, mandibular rotational angle and distance of clickin group were significantly greater than those of control group in horizontal plane. (P<0.05). 4. On lateral excursion, there was no significant difference in mandibular rotational angle and distance between clicking group and control group in frontal and horizontal planes. 5. There were significant correlations between peak amplitude of TMJ sounds and maximum mandibular rotational distance during maximum mouth opening (r=-.481) and mandibular rotational distance on maximum mouth opening (r=-.455) in horizontal plane. 6. There were significant correlations between Above 300/(0-300)Hz ratio of TMJ sounds and mandibular rotational angle (r=-.499) and distance (r=-.457) on maximum mouth opening in frontal plane.

  • PDF

Effects of Head Posture on the Rotational Torque Movement of Mandible in Patients with Temporomandibular Disorders (두경부 위치에 따른 측두하악장애환자의 하악 torque 회전운동 분석)

  • Park, Hye-Sook;Choi, Jong-Hoon;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.2
    • /
    • pp.173-189
    • /
    • 2000
  • The purpose of this study was to evaluate the effect of specific head positions on the mandibular rotational torque movements in maximum mouth opening, protrusion and lateral excursion. Thirty dental students without any sign or symptom of temporomandibular disorders(TMDs) were included as a control group and 90 patients with TMDs were selected and examined by routine diagnostic procedure for TMDs including radiographs and were classified into 3 subgroups : disc displacement with reduction, disc displacement without reduction, and degenerative joint disease. Mandibular rotational torque movements were observed in four head postures: upright head posture(NHP), upward head posture(UHP), downward head posture(DHP), and forward head posture(FHP). For UHP, the head was inclined 30 degrees upward: for DHP, the head was inclined 30 degrees downward: for FHP, the head was positioned 4cm forward. These positions were adjusted with the use of cervical range-of-motion instrumentation(CROM, Performance Attainment Inc., St. Paul, U.S.A.). Mandibular rotational torque movements were monitored with the Rotate program of BioPAK system (Bioresearch Inc., WI, U.S.A.). The rotational torque movements in frontal and horizontal plane during mandibular border movement were recorded with two parameters: frontal rotational torque angle and horizontal rotational torque angle. The data obtained was analyzed by the SAS/Stat program. The obtained results were as follows : 1. The control group showed significantly larger mandibular rotational angles in UHP than those in DHP and FHP during maximum mouth opening in both frontal and horizontal planes. Disc displacement with reduction group showed significantly larger mandibular rotational angles in DHP and FHP than those in NHP during lateral excursion to the affected and non-affected sides in both frontal and horizontal planes(p<0.05). 2. Disc displacement without reduction group showed significantly larger mandibular rotational angles in FHP than those in any other head postures during maximum mouth opening as well as lateral excursion to the affected and non-affected sides in both frontal and horizontal planes. Degenerative joint disease group showed significantly larger mandibular rotational angles in FHP than those in any other head postures during maximum mouth opening, protrusion and lateral excursion in both frontal and horizontal planes(p<0.05). 3. In NHP, mandibular rotational angle of the control group was significantly larger than that of any other patient subgroups. Mandibular rotational angle of disc displacement with reduction group was significantly larger than that of disc displacement without reduction group during maximum mouth opening in the frontal plane. Mandibular rotational angle of disc displacement without reduction group was significantly larger than that of disc displacement with reduction group or degenerative joint disease group during maximum mouth opening in the horizontal plane(p<0.05). 4. In NHP, mandibular rotational angles of disc displacement without reduction group were significantly larger than those of the control group or disc displacement with reduction group during lateral excursion to the affected side in both frontal and horizontal planes. Mandibular rotational angle of disc displacement without reduction group was significantly smaller than that of the control group during lateral excursion to the non-affected side in frontal plane. Mandibular rotational angle of disc displacement without reduction group was significantly larger than that of disc displacement with reduction group during lateral excursion to the non-affected side in the horizontal plane(p<0.05). 5. In NHP, mandibular rotational angle of the control group was significantly smaller than that of disc displacement with reduction group or disc displacement without reduction group during protrusion in the frontal plane. Mandibular rotational angle of disc displacement without reduction group was significantly larger than that of the disc displacement with reduction group or degenerative joint disease group during protrusion in the horizontal plane. Mandibular rotational angle of the control group was significantly smaller than that of disc displacement without reduction group or degenerative joint disease group during protrusion in the horizontal plane(p<0.05). 6. In NHP, disc displacement without reduction group and degenerative joint disease group showed significantly larger mandibular rotational angles during lateral excursion to the affected side than during lateral excursion to the non-affected side in both frontal and horizontal planes(p<0.05). The findings indicate that changes in head posture can influence mandibular rotational torque movements. The more advanced state is a progressive stage of TMDs, the more influenced by FHP are mandibular rotational torque movements of the patients with TMDs.

  • PDF

Finding of Relation Between 4th Lumbar Rotational Malposition and Scoliosis (요추 4번의 회전변위와 척추측만증과의 상관성에 관한 연구)

  • Kim, Gyu-Sub;Kim, Jae-Young;Min, Young-Kwang;Seo, Young-Tae;Sung, Ik-Jae;Lee, Seung-Woo;Jee, Jae-Dong
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.7 no.1
    • /
    • pp.27-34
    • /
    • 2012
  • Objectives : The purpose of this study is to find out the relation between 4th lumbar rotational malposition and scoliosis. Methods : We investigated 22 cases of patients who were diagnosed as scoliosis. We used AP & Lateral view X-ray for patients. And we analysed the relation between 4th lumbar rotational malposition and scoliosis. Results : P-value was 0.436 between 4th lumbar rotational amount and lordotic angle, and was 0.758 between 4th lumbar rotational amount and wedge angle(p>0.05). And p-value was 0.022 between 4th lumbar rotational amount and scoliotic apex rotational amount(p<0.05), but was 0.286 between 4th lumbar rotational amount and Cobb's angle(p>0.05). Conclusions : The results suggest that 4th lumbar rotational malposition was statistically correlation with scoliotic apex rotational malposition, was not Cobb's angle, 4th lumbar lordotic & wedge angle.

  • PDF

A study on the Rotational Torque Movement of Mandible in TMJ Closed Lock (폐구성 악관절 과두걸림환자의 하악회전운동에 관한 연구)

  • Kim, Kyoung;Chung, Sung-Chang;Yeon, Tae-Ho
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.2
    • /
    • pp.207-217
    • /
    • 1997
  • This study was performed for Investigation of the magnitude of mandibular positional change in maximum mouth opening. protrusion, lateral excursion, gum and peanut chewing with BioPAK system(Bioresearch Inc. USA) which can analyze mandibular rotational torque movements. For this study 17 female patients with Temporomandibular joint(TMJ) closed lock and 18 female control without any Temporomandibular disorders(TMDs) signs and premature occlusal contact were included. The obtained results were as follows : 1. In maximum mouth opening, the mandibular rotational angle and distance of patients were significantly greater than those of control group in horizontal plane(P<0.05). 2. In protrusion, the mandibular rotational angle and distance of patients were significantly greater than those of control group in frontal and horizontal plane(P<0.01, P<0.05). 3. The mandibular rotational angle and 야stance in lateral excursion to affected side of patients were significantly greater than those in lateral excursion to non-affected side in frontal plane(P<0.05). 4. The mandibular rotational angle in gum chewing to affected side of patients was significantly greater than that in gum chewing to non-affected side in frontal plane. 5. The mandibular rotational angle and distance in peanut chewing to affected side of patients were significantly greater than those in peanut chewing to non-affected side in frontal and horizontal plane. 6. The mandibular rotational angle and distance in peanut chewing to affected side of patients were greater than those in gum chewing, and was the same result in control group in frontal and horizontal plane.

  • PDF

Inviscid Rotational Flows Near a Corner and Within a Triangle

  • Suh, Yong-Kweon
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.813-820
    • /
    • 2001
  • Solutions of inviscid rotational flows near the corners of an arbitrary angle and within a triangle of arbitrary shapes are presented. The corner-flow solutions has a rotational component as a particular solution. The addition of irrotatoinal components yields a general solution, which is indeterminate unless the far-field condition is imposed. When the corner angle is less than 90$^{\circ}$the flow asymptotically becomes rotational. For the corner angle larger than 90$^{\circ}$it tends to become irrotational. The general solution for the corner flow is then applied to rotational flows within a triangle (Method I). The error level depends on the geometry, and a parameter space is presented by which we can estimate the error level of solutions. On the other hand, Method II employing three separate coordinate systems is developed. The error level given by Method II is moderate but less dependent on the geometry.

  • PDF

Machining Tolerance of Various Implant Systems and their Components (치과용 임플란트 시스템의 기계적 가공오차에 관한 연구)

  • Kim, Hyeong-Seob;Kwon, Kung-Rock;Han, Jung-Suk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.57-65
    • /
    • 2008
  • Purpose: Misfit of implant components was very important in terms of prosthodontics. they has been linked to prosthetic complications such as screw loosening and fracture. Although there are many results about rotational freedom or machining tolerance between fixture and abutments, the data about domestic implant systems are lacking. The aim of this in vitro study was to evaluate the rotational freedom of domestic external and internal connection implant systems between their fixtures/anlaogs and abutments comparing imported systems. Materials and Methods: Rotational freedom between abutments and fixtures/analogs was investigated by using digitalized rotational angle measuring device. (1) 1 domestic external connection system(Neobiotec) and 2 imported external connection systems(Nobel Biocare, Anthorgyr), (2) 1 domestic internal connection system(Dentium) and 4 imported external connection systems(Nobel Biocare, Anthorgyr, Straumann, Frident Dentsply), and (3) 1 domestic zirconia external connection abutment(ZirAce) were evaluated. Each group has 3 samples. Mean values for each group were analyzed. Results: The differences relative to rotational freedom between domestic and imported implant systems were observed but domestic external connection implant system showed about 2.67 degrees(in case of fixture) and internal connection system showed about 4.3 degrees(in case of fixture). Domestic zirconia abutment showed less than 3 degrees of rotational freedom in a situation where the abutment was connected to an implant fixture egardless of domestic or imported systems. Conclusion: Newly developed digitalized rotational angle measuring device has high measuring resolution. The rotational freedom of domestic implant systems were similar to imported implant systems.

Factor Affecting Mandibular Rotational Troque Movements (하악의 비틀림회전운동에 영향을 미치는 요인)

  • 이유미;한경수;허문일
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.2
    • /
    • pp.143-155
    • /
    • 1998
  • This study was performed to investigate the factor that might affect mandibualr body rotation. For the study, 115 patients with temporomandibular disorders and 35 dental students without angy signs and symptoms of temporomandibular disorders were randomly selected as the patient group and the contreol group, respectively. Preferred chewing side, Angle' classification, lateral guidance pattern, and affected side were clinically recorded, and the amount of Mandibular body rotational torque movement was measured in wide opening and closure, in right and left excursion with vertical and lateral distance in frontal plane, right and left rotational angel in horizontal and in frontal plane. Masticatory muscle activity of anteriorocclusal contact pattern on maximal hard biting were also observed synchronously with BioEMG and T-Scan , respectively. The observed items were muscle activity of anterior temporalis and superficial masseter, and tooth contact status related to contact number, force, duration, and occlusal unbalance between right and left arch. The data collected were analyzed by SAS statistical program. The results of this study were as follows : 1. Mean value of vertical distance in frontal plane in wide opening and closure was more in control subjects than in patients, but there was no difference for rotational angle. In right excursion, rotational angles were greater in patient group than in control group. 2. Comparison among the subjects by preferred chewing side did not reveal any significant difference, but comparison among patients by affected side showed more rotational amount in bilaterally affected patients than in unilaterally affected patients. 3. Comparison among the subjects by Angle's classification or lateral guidance pattern revealed no difference. There was also no difference between preferred chewing side and contralateral side, and between affected side and contralateral side. 4. Positive correlation in madibular rotational torque movements were observed among vertical distance, total horizontal rotation angle, electromyographic activity of anterior temporalis, tooth contact number, and tooth contact force but total frontal rotation angle almost did not show any correlation with other variables except vertical distance.

  • PDF

The Effect of the Variation of the Number of Bolts on the Rotational Stiffnesses of Double Angle Connections (볼트수의 변화가 더블앵글 접합부의 회전강성에 미치는 영향)

  • Yang, Jae-Geun;Kim, Ho-Keun;Kim, Ki-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.1 s.11
    • /
    • pp.69-75
    • /
    • 2004
  • In the construction of row-rise steel buildings, double angle connection can be considered as one of most effective connection types. Its connection flexibility depends mainly on several parameters such as angle thickness, bolt gage distance, and number of bolts. To establish the effect of the variation of the number of bolts on the moment-rotation relationship, three experimental tests have been conducted in this research. Based on the results of each experimental test, the rotational stiffness of each angle specimen can be calculated by performing regression analysis. Considering the results of regression analysis, we concluded that the more the number of bolts used in double angle connection, the higher the rotational stiffness as one can expected.

  • PDF

Development of a Inchworm-Type Precise Rotational Motor (자벌레형 정밀 회전 모터의 개발)

  • 김상채;김수현;곽윤근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.458-461
    • /
    • 1995
  • A new type of rotational motor which is developed has a resolution smaller than 10 $^{-4}$ radian and can be accessed for full rotational angles. The operation principle of the motor is based on inchworm motion of two belt driving mechanism. Flexure hinge mechanism, which is pertinent to symmetry construction of the motor, is designed to minimze the effort to frame and is analyzed by using finite element method. Depending on input signal amplitude, rotational angle by one cycle is varied form 0.2*10 $^{-4}$ rad to 9.76* $^{-4}$ rad. This shows that it has the capability of getting very small rotational angle by considering radius of rotor and amplitude of input signal.

  • PDF