• Title/Summary/Keyword: SAFIR

Search Result 5, Processing Time 0.018 seconds

Numerical analysis of partially fire protected composite slabs

  • Zaharia, R.;Vulcu, C.;Vassart, O.;Gernay, T.;Franssen, J.M.
    • Steel and Composite Structures
    • /
    • v.14 no.1
    • /
    • pp.21-39
    • /
    • 2013
  • The paper presents a numerical investigation, done with the computer program SAFIR, in order to obtain simpler finite element models for representing the behaviour of the partially protected composite steel concrete slabs in fire situations, considering the membrane action. Appropriate understanding and modelling of the particular behaviour of composite slabs allows a safe approach, but also substantial savings on the thermal insulation that has to be applied on the underlying steel structure. The influence of some critical parameters on the behaviour and fire resistance of composite slabs such as the amount of reinforcing steel, the thickness of the slab and the edge conditions is also highlighted. The results of the numerical analyses are compared with the results of three full scale fire tests on composite slabs that have been performed in recent years.

Towards a consistant safety format of steel beam-columns: application of the new interaction formulae for ambient temperature to elevated temperatures

  • Vila Real, P.M.M.;Lopes, N.;Simoes da Silva, L.;Piloto, P.;Franssen, J.M.
    • Steel and Composite Structures
    • /
    • v.3 no.6
    • /
    • pp.383-401
    • /
    • 2003
  • Two new formulae for the design of beam-columns at room temperature have been proposed into Eurocode 3, prEN 1993-1-1 (2002), and are the result of great efforts made by two working groups that followed different approaches, a French-Belgian team and an Austrian-German one. Under fire conditions the prEN 1993-1-2 (structural fire design) presents formulae, for the design of beam-columns based on the prENV 1993-1-1 (1992). In order to study the possibility of having, in part 1-1 and part 1-2 of the Eurocode 3, the same approach, a numerical research was made using the finite element program SAFIR, developed at the University of Liege for the study of structures subjected to fire.

Fire design of concrete encased columns: Validation of an advanced calculation model

  • Zaharia, R.;Dubina, D.
    • Steel and Composite Structures
    • /
    • v.17 no.6
    • /
    • pp.835-850
    • /
    • 2014
  • The fire resistance of composite steel and concrete structures may be determined by using the simplified methods provided in EN 1994-1-2. For the particular situations not covered by the standard, an advanced calculation model might be applied, using special purpose programs for the analysis of structures in fire. The validation of these programs has always been an important issue for software developers, but also for designers and authorities. Clause 4.4.4 from EN 1994-1-2 refers to the validation of the advanced calculation models and states that these models must be validated through relevant test results. The paper presents the calculation of fire resistance of the composite columns in a high-rise building built in Romania, and focusses on the validation of the calculation model (computer program SAFIR), for this particular case. This validation, asked by the Romanian authorities, considers the available experimental results of a fire test, performed on a similar composite steel-concrete column.

Simple equations for the calculation of the temperature within the cross-section of slim floor beams under ISO Fire

  • Zaharia, R.;Franssen, J.M.
    • Steel and Composite Structures
    • /
    • v.13 no.2
    • /
    • pp.171-185
    • /
    • 2012
  • The calculation of fire resistance for a composite structural element comprises the calculation of the temperature within its cross-section and of the load bearing capacity, considering the evolution of the steel and concrete mechanical properties, function of the temperature. The paper proposes a method to calculate the bending capacity under ISO fire, for Slim Floor systems using asymmetric steel beams, with a wider lower flange or a narrow upper flange welded onto a half hot-rolled profile. The temperatures in the cross-section are evaluated by means of empirical formulas determined through a parametrical analysis, performed with the special purpose non-linear finite element program SAFIR. Considering these formulas, the bending capacity may be calculated, using an analytical approach to determine the plastic bending moment, for different fire resistance demands. The results obtained with this simplified method are validated through numerical analysis.

The Characteristics of Winter Lightning Observed in the Mid-western Part of Japan (일본 중서부지방에서 발생하는 동계 뇌 방전의 특징)

  • Lee, Jong-Ho;Kawasaki, Z.;Ryu, Chan-Su
    • Journal of the Korean earth science society
    • /
    • v.24 no.3
    • /
    • pp.181-189
    • /
    • 2003
  • This study analyzes the results of thunderstorm data observed in the mid-western part of Japan during the winter of 1996-1997. There were 35 instances of thunderstorms with 4,426 instances of lightning detected during the observation period. This study estimates the frequency of lightning occurrence through classification of detected lightning into two types, and analyzes the relationship between lightning types and synoptic pattern. According to the analyzed results, cloud-to-cloud discharge and positive polarity occupied 78% and 42.3% of total discharge, respectively. It is rare for lightning to occur in the winter season, usually occuring during the night (midnight to 5 a.m.). Lightning frequently occurs when there is a prevailing synoptic wind from the norhwest. According to the analyzed results of multiplicity and multi-point lightning, the mean values of multiplicity and multi-point lightning are 1.4 and 1.2, respectively.