• Title/Summary/Keyword: SIMPLE

Search Result 34,881, Processing Time 0.054 seconds

Quantum group $X_q(2)$

  • Oh, Sei-Qwon;Shin, Yong-Yeon
    • Communications of the Korean Mathematical Society
    • /
    • v.10 no.3
    • /
    • pp.575-581
    • /
    • 1995
  • The simple modules and the simple comodules of the quantum group $X)q(2)$ defined by M. L. Ge, N. H. Jing and Y. S. Wu, are classified.

  • PDF

The Effect of Dose Distribution under Treatment Techniques on Cerebrospinal Irradiation (뇌 및 척수조사시 치료기법의 변화가 선량분포에 미치는 영향)

  • Lee, Seungchul;Kim, Youngjae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • This study tries to evaluate the usefulness CSI treatment. Compare the standard technique and simple technique, using the volume region of a high dose of Field joints (hot spot) or low dose regions (cold Spot). In patients who agreed to this study, obtain CT image using CT simulator skull to pelvis region. Standard Technique were performed on the movement of the joint radiation field range and simple technique has set a treatment plan to secure the radiation field range and analyzed treatment planning. Under analysis standard technique occurred the area of the high dose(Hot Spot) for the area overlapping the field and simple technique showing a uniform doses. CI indices of standard technique and simple technique was 1.6~3, 1.6~1.87, CN indices was 0.32~0.53, 0.46~0.51 and HI indices was 0.11~0.33, 0.2~0.26. Therefore, adjacent to part of the dose distribution junction more equally than simple technique compared to the Standard Technique. Compare the dose distribution patterns using CI, CN, HI indices, showed a uniform dose distribution in the simple technique. so, simple technique was determined appropriate treatment the CSI.

A Simple Distillation Process Produce Fuel from Plastic Waste using Incorporate Heat Source

  • Thawichsri, Kosart;nilnont, Wanich
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.127-136
    • /
    • 2015
  • This paper is a study of a simple distillation process. Its objective is to compare fuel production from plastic waste, its data collecting is from the factory and simple data calculated a suitable evaluation on the simple distillation plant built before calculation. The experiment with a simple distillation process is separated into three sections. The first section is a simple distillation process of distillation producing diesel using heat source by biomass. The second section is distillation process which produces fuel using heat source by burner. The third section uses heat source by burner incorporate with biomass. The experiment reveals that the result of the second section is the most efficient. In comparison with the experiments and the simple calculation, the result on the efficiency of work has error less than 5% and it is sufficient for the next experimental process. Thus, the study and design on a simple distillation process produces fuel from plastic waste has to concern mainly on design heat exchangers, flow rate and optimized temperature. Further study on this plant can be developed throughout the county due to its low cost and efficiency.

Study on Pedestrian Protection device in collision using Pneumatic cylinder and simple link mechanism (공압 실린더 및 단순 링크기구를 이용한 충돌 보행자 보호 장치에 관한 연구)

  • Noh, S.H.;Lee, D.R.
    • Journal of Power System Engineering
    • /
    • v.12 no.4
    • /
    • pp.64-71
    • /
    • 2008
  • This study is on pedestrian protection device using pneumatic cylinder and simple link mechanism when vehicle collide with pedestrian. This study ensured the safety space between engine and hood after it applies to simple link mechanism and pneumatic cylinder. It can absorb the damage which measure the specific device if vehicle collide with pedestrian. Combination of simple link mechanism and pneumatic cylinder was more superior than the present pedestrian protection device. Simple link mechanism could confirm superior height and survival probability than when only cylinder operated. It also ensured enough space between engine and hood. And if a cylinder is not working because of old cylinder, poor repair or damage of accident vertical cylinder would be difficult to execute because there exists the irregular space between engine and hood. If simple link mechanism operates with only one cylinder it could ensure the regular space because simple link mechanism set up at the middle of hood. So this device could confirm high safety for pedestrian.

  • PDF

A Study on the Improvement Directions of Mobile Simple Payment System: Usage Status Point of View (모바일 간편결제 시스템 개선 방향 연구: 이용 실태 관점)

  • Choi, Heesik;Cho, Yanghyun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.4
    • /
    • pp.51-62
    • /
    • 2019
  • Recently, as the number of Smart Phone users increase, the simple payment system has been able to make payments using only card information such as a registered password without extra authorized certificate authentication or input of card information. In this paper, it will examine and analyze simple payment system provided by IT companies and financial institutions and the simple payment system that operates global online payment system by case view of operational direction. Then with this examination, it will study ways to improve the problems with terms of convenience and stability in terms of users. In this paper, it will analyze the inconvenient problem in using the QR code system that recently introduced and will propose solutions. Also, it will propose suggestions to solve inconvenience that caused by system that supports NFC simple payment terminal in Korea is not universalize by analyze case study on the overseas simple payment system. It will also propose opinions on the matters that customer having responsible for event of a small financial accident related to loss or theft when using the simple payment system. Then it will suggest expected requirements to prepare new security technical countermeasures and solve the conditions of meeting expectation satisfaction of users.

Treatment of Class I crowding using simple tubes bonded with customized resin coverings: A case report

  • Jeong, Seo-Rin;Kim, Hye-In;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.116-123
    • /
    • 2019
  • As an alternative to the conventional fixed appliance that uses orthodontic brackets, a simple round tube without a bonding base can be bonded to the tooth surface by covering the tube with flowable resin. In this technique, bent wires cannot be inserted into the simple tubes; therefore, repositioning of the simple tubes is often required for adjustments. To reduce repositioning of simple tubes, a dome-shaped resin covering of the simple tube can be designed with a customized in-and-out compensation, using three-dimensional computer-aided design software based on digital simulation of orthodontic tooth movement. In the present case, the use of simple tubes bonded with customized resin coverings in a Class I nonextraction case is described in a 17-year-old male, in whom moderate crowding of the anterior teeth was treated over an 8-month period. This case shows that simple tubes can be used as an alternative to brackets in some Class I nonextraction cases, with the potential benefit of reducing decalcification.

Correlation among Functional Leg Length Discrepancy, Muscle Activity, Muscle Contraction Onset Time and Vertical Ground Reaction Force during Simple Lifting Task

  • Jin, Ha Young;Han, Jin Tae
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.4
    • /
    • pp.175-180
    • /
    • 2022
  • Purpose: Leg length discrepancy causes the posture deformation, gait asymmetry, and lower back pain. The purpose of this study is to investigate the correlation among functional leg length discrepancy (FLLD), muscle activity, muscle contraction onset time and vertical ground reaction force (vGRF) during simple lifting task. Methods: Thirty-nine subjects participated in this study. FLLD was measured from the umbilicus to medial malleolus of left and right leg using a tape. The subjects performed to lift a 10 kg box from the floor to chest. The muscle activity and muscle contraction onset time of rectus abdominis, erector spinae and rectus femoris was measured using EMG system and vGRF was measured by two force plate. Pearson correlation was used to fine out the correlation among FDDL, muscle activity, muscle contraction onset time and vGRF during simple lifting task. Results: Correlation between FLLD and difference of muscle activity of short-long side was very high (r>0.9) during simple lifting task. Correlation between FLLD and difference of muscle contraction onset time of short-long side was very high (r>0.9) during simple lifting task. And correlation between FLLD and difference of vGRF of short-long side was high (r>0.7) during simple lifting task. Conclusion: This study suggests that there is high correlation between FLLD and muscle activity, muscle contraction onset time, and ground reaction force during simple lifting task. Therefore, FLLD could negatively affect the postural balance.

IOTA Simple Rules in Differentiating between Benign and Malignant Adnexal Masses by Non-expert Examiners

  • Tinnangwattana, Dangcheewan;Vichak-ururote, Linlada;Tontivuthikul, Paponrad;Charoenratana, Cholaros;Lerthiranwong, Thitikarn;Tongsong, Theera
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.9
    • /
    • pp.3835-3838
    • /
    • 2015
  • Objective: To evaluate the diagnostic performance of IOTA simple rules in predicting malignant adnexal tumors by non-expert examiners. Materials and Methods: Five obstetric/gynecologic residents, who had never performed gynecologic ultrasound examination by themselves before, were trained for IOTA simple rules by an experienced examiner. One trained resident performed ultrasound examinations including IOTA simple rules on 100 women, who were scheduled for surgery due to ovarian masses, within 24 hours of surgery. The gold standard diagnosis was based on pathological or operative findings. The five-trained residents performed IOTA simple rules on 30 patients for evaluation of inter-observer variability. Results: A total of 100 patients underwent ultrasound examination for the IOTA simple rules. Of them, IOTA simple rules could be applied in 94 (94%) masses including 71 (71.0%) benign masses and 29 (29.0%) malignant masses. The diagnostic performance of IOTA simple rules showed sensitivity of 89.3% (95%CI, 77.8%; 100.7%), specificity 83.3% (95%CI, 74.3%; 92.3%). Inter-observer variability was analyzed using Cohen's kappa coefficient. Kappa indices of the four pairs of raters are 0.713-0.884 (0.722, 0.827, 0.713, and 0.884). Conclusions: IOTA simple rules have high diagnostic performance in discriminating adnexal masses even when are applied by non-expert sonographers, though a training course may be required. Nevertheless, they should be further tested by a greater number of general practitioners before widely use.

An efficient quality improvement scheme for magnified image by using simple convex surface and simple concave surface characteristics in image (영상의 단순 볼록 곡면과 단순 오목 곡면 특성을 이용한 확대 영상의 효율적인 화질 개선 기법)

  • Jung, Soo-Mok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.11
    • /
    • pp.59-68
    • /
    • 2013
  • In this paper, an effective scheme was proposed to estimate simple convex surface and simple concave surface which exist in image. This scheme is applied to input image to estimate simple convex surface or simple concave surface. When simple convex surface or simple concave surface exists, another proposed efficient interpolation scheme is used for the interpolated pixel to have the characteristics of simple convex surface or simple concave surface. The magnified image using the proposed schemes is more similar to the real image than the magnified image using the previous schemes. The PSNR values of the magnified images using the proposed schemes are greater than those of the magnified images using the previous interpolation schemes.

"Pool-the-Maximum-Violators" Algorithm

  • Kikuo Yanagi;Akio Kudo;Park, Yong-Beom
    • Journal of the Korean Statistical Society
    • /
    • v.21 no.2
    • /
    • pp.201-207
    • /
    • 1992
  • The algorithm for obtaining the isotonic regression in simple tree order, the most basic and simplest model next to the simple order, is considered. We propose to call it "Pool-the-Maximum-Violators" algorithm (PMVA) in conjunction with the "Pool-Adjacent-Violators" algorithm (PAVA) in the simple order. The dual problem of obtaining the isotonic regression in simple tree order is our main concern. An intuitively appealing relation between the primal and the dual problems is demonstrated. The interesting difference is that in simple order the required number of pooling is at least the number of initial violating pairs and any path leads to the solution, whereas in the simple tree order it is at most the number of initial violators and there is only one advisable path although there may be some others leading to the same solution.o the same solution.

  • PDF