• Title/Summary/Keyword: SM490TMC

Search Result 13, Processing Time 0.028 seconds

Formulation of Cyclic Plasticity Model and FE Analysis for SM490 TMC (SM490 TMC 강재의 반복소성모델의 정식화 및 유한요소해석)

  • 장갑철;장경호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.84-89
    • /
    • 2004
  • In this paper, cyclic plasticity model of SM490 TMC was formulated by basing on monotonic loading test and cyclic loading test. For exact description of cyclic performance and plastic deformation capacity of steel member using SM490 TMC, formulated cyclic plasticity model and finite deformation theory were applied to 3-dimensional elastic-plastic FE analysis. Cyclic plastic behavior of pipe-section steel column using SM490 TMC was clarified by carrying out numerical analysis. Also, in order to clarifying seismic performance of pipe-section steel column using SM490 TMC, analysis results were compared with analysis results of pipe-section steel column using SM490. A comparison of analysis results shows that SM490 TMC pipe-section steel column has a better cyclic performance for strength and energy dissipation than SM490 pipe-section steel column under cyclic loading

  • PDF

Hysteretic Behavior Characteristics of SM490-TMC Steel Column (SM490-TMC 강재를 적용한 기둥부재 이력거동의 특성)

  • Chang, Kyong Ho;Jang, Gab Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5A
    • /
    • pp.833-840
    • /
    • 2006
  • In design of steel column member using TMCP steels, hysteretic behavior characteristics of steel column must be clarified. To predict hysteretic behavior of steel column using TMCP steels, a cyclic plasticity model is necessary which can consider the mechanical characteristics and stress-strain relationship of TMCP steels. In this paper, a cyclic plasticity model of SM490-TMC was formulated based on monotonic and cyclic loading tests. The formulated cyclic plasticity model was applied to 3-dimensional finite element analysis. Hysteretic behavior characteristics of steel circular column and H-section column using SM490-TMC was presented by carrying out numerical analysis. Also, influence of SM490-TMC on hysteretic behavior of steel column was presented by comparing analysis results both SM490 and SM490-TMC steel column.

A Study of Material Characteristics of 120mm-Thick SM490TMC Plate (SM490TMC 극후판재 120mm의 소재특성에 관한 연구)

  • Kim, Sang Seup;Lee, Cheol Ho;Lee, Eun Taik;Han, Tae Ho;Choi, Young Han;Kim, Jong Rak
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.5
    • /
    • pp.313-323
    • /
    • 2016
  • Seven types of tests were conducted to experimentally evaluate the material properties of ultral-thick (or 120mm-thick) SM490TMC plate. The investigation of through-thickness properties was among the most significant considerations. All chemical and mechanical test results showed the through-thickness homogeneity as required and conformed to the KS(Korean industrial Standards), although the thickness was 1.5 times thicker than the thickness limit (80mm) imposed by Steel Structure Design Code. No reduction in the yield strength of 120mm-thick SM490TMC plate is recommended for design.

A Study of Weldability and Welded Joint Performance on the Gas Shield Arc Welding (FCAW) of SM490TMC Steel Plate (120mm) (SM490TMC 극후판(120mm) 강재의 가스실드아크용접(FCAW)을 이용한 용접성 및 이음성능에 관한 연구)

  • Kim, Sung Bae;Hong, Hyung Ju;Choi, Young Han;Kim, Sang Seup
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.455-465
    • /
    • 2017
  • To figure out the weldability and welded joint performance on the FCAW of SM490TMC 120mm, several specimens were manufactured and 10 kinds of experiments were implemented. The result of the weld zone chemical composition test, weld metal tensile test, weld zone tensile test, and weld zone impact test has satisfied the KS. Especially, the weld zone tensile test result shows the base metal fracture, which means the weld zone performs enough required performance. In addition, the results of the weld zone bending test, hardness test, macroscopic test, microscopic test, and the maximum hardness in HAZ were showing that the FCAW weld zone has fine quality.

A Study on Mechanical Properties of SM490-TMC Back Plate(40 mm) Steel by SAW Welding (SM490-TMC 후판(40 mm) 강재의 SAW 용접을 통한 기계적 특성 연구)

  • Lee, Soung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.88-93
    • /
    • 2021
  • SAW (Submerged Arc Welding) is often used for ship construction or welding pressure vessels and involves spraying a flux in a powder form to a welding site to a certain thickness and continuously supplying electrode wires therein. This welding method enables high current welding up to 1,500 to 3,000 A. Arc efficiency is higher than 95% and the technique allows clean work as it creates less welding fume, which is composed of fine metal oxide particles, and the arc beam is not exposed. In this study, SM490C-TMC thick plates were heterogeneously welded by SAW. Mechanical properties of welds were measured, and welds were assessed macroscopically and for adhering magnetic particles. The following conclusions were drawn. Bending tests showed no spots exploded on sample surfaces or any other defect, and plastic deformation testing confirmed sufficient weld toughness. These results showed the 1F welding method has no shortcomings in terms of bending performance.

A Study on Elasto-Plastic Behavior of Column-to-Beam Welded Connection with 600MPa Class High Performance Steel (600MPa급(SM 570 TMC) 고성능강 기둥-보 용접접합부의 탄소성 거동에 관한 연구)

  • Kim, Jong Rak;Oh, Young Suk;Baek, Ki Youl;Chang, Sung Yun
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.783-792
    • /
    • 2008
  • While the recent high demand for mega-tall buildings has led to the development of high-performance and high-strength steels, the requirements for architectural-structure-performance steel have been raised as engineers recognize the potential damage that an earthquake can wreak on a tall building. A 600MPa-class steel has emerged to meet such need, and many studies are currently exploring its practical applications on civil engineering works and mega-tall buildings. The available data on the horizontal-force behaviors of structures built with such new steel, however, are still insufficient. There is an urgent need to look into its design data, especially its toughness, and to compare the plastic strain ratios of column-to-beam connections using high-strength steel and regular steel. One of the first studies on the behavior of a column-to-beam connection using 600MPa-class steel (SM570 TMC), this thesis analyzes such steel's structural performance by conducting a structural test on seismic resistance on a full-scale column-to-beam welded connection with non-scallop and recommended-scallop details. Compared with the previous studies on SM490, this thesis evaluates the weldability of SM570 TMC and presents the latter's seismic design data for use in testing its practical application.

Flexural Strength of HSB Plate Girder with Compact or Noncompact Web Due to Inelastic Lateral-Torsional Buckling (조밀 또는 비조밀 복부판을 갖는 HSB 플레이트거더의 비탄성 횡비틀림좌굴에 의한 휨강도)

  • Shin, Dong Ku;Cho, Eun Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6A
    • /
    • pp.399-409
    • /
    • 2012
  • The flexural behavior of HSB plate girder with a non-slender web, due to inelastic lateral-torsional buckling, under uniform bending was investigated by the nonlinear finite element analysis. Both homogeneous sections fabricated from SM570-TMC, HSB600 or HSB800 steel and hybrid sections with HSB800 flanges and SM570-TMC web were considered. The flanges and web of selected noncomposite I-girders were modeled as thin shell elements and the geometrical and material nonlinear finite element analysis was performed by the ABAQUS program. The steel was assumed as an elasto-plastic strain hardening material. Initial imperfections and residual stresses were taken into account and their effects on the inelastic lateral-torsional buckling behavior were analyzed. The flexural strengths of selected sections obtained by the finite element analysis were compared with the nominal flexural strengths from KHBDC LSD, AASHTO LRFD, and Eurocode and the applicability of these codes in predicting the inelastic lateral torsional buckling strength of HSB plate girders with a non-slender web was assessed.

A Study on Structural Characteristics of SM490A TMC Thick Steel Plates (SM490A TMC 후판강재의 소재 및 용접부 특성에 관한 연구)

  • Kim, Jong Rak;Park, Yang Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.331-339
    • /
    • 2003
  • The study discussed in this paper investigated the material characteristics for the Thermo-Mechanical Control Process(TMCP) plates, which are controlled by several factors such as rolling, cold-stripping, cooling rate, and fixed carbon quantity. The suitability of thick TMCP steel plates as structural steel was also estimated through several experiments and with the us of a statistical method to analyze mill certificate sheets provided by the manufacturer. The results of this study are as follows: the TMCP steel plates showed stable values of the composition parameter ($P_cm$) and the carbon equivalents ($C_eq$ ) with satisfied yield strength, ultimate strength, and low-yield ratio.

Performance Examination and Comparison of Steel Beam-Column Connection in SM570TMC for Mixed-Use (고강도강 혼용 사용을 위한 SM570TMC강 보-기둥 접합부의 성능평가 및 해석 비교)

  • Kim, Moonjeong;Cho, Sukhee;Ha, Tae-Uk;Kang, Chang-Hoon;Choi, Woo-Hyuk;Kim, Jung-Hak
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.3
    • /
    • pp.22-29
    • /
    • 2013
  • In recent years, the construction of high-rise buildings are promoted. According to these, there are many needs about new technologies to strengthen the building performance and high-strength steel is regarded as one of these for promoting building performance. In Korea, high-strength steels which stress are over 600MPa are on market and in aborad, super high-strength steels over 1000MPa are developing and they expected to promote the building performance. But there are still doubts about applying high-strength steel members because of size effect and worry of brittle fracture. In this reports, we propose results of performance and analysis tests for use with general steel. We propose the characteristic of high-strength steels first and next the results of performance test to show they satisfy the performance that designers expect. And last, we compare the results of test and analysis for acquire the alanysis reliability in non-linear analysis with high-strength steels.

Flexural Strength of HSB I-Girder Considering Inelastic Flange Local Buckling (압축플랜지 비탄성 국부좌굴을 고려한 HSB 플레이트거더의 휨강도)

  • Cho, Eun Young;Shin, Dong Ku
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.81-92
    • /
    • 2013
  • The ultimate flexural strength of HSB I-girders, considering the effect of local bucking, was investigated through a series of nonlinear finite element analysis. The girders were selected such that the inelastic local flange buckling or the plastic yielding of compression flanges governs the flexural strength. Both homogeneous sections fabricated from HSB600 or HSB800 steel and hybrid sections with HSB800 flanges and SM570-TMC web were considered. In the FE analysis, the flanges and web were modeled using thin shell elements and initial imperfections and residual stresses were imposed on the FE model. An elasto-plastic strain hardening material was used for steels. After establishing the validity of present FE analysis by comparing FE results with test results published in the literature, the effects of initial imperfection and residual stress on the inelastic flange local buckling behavior were assessed. The ultimate flexural strengths of 60 I-girders with various compression flange slenderness were obtained by FE analysis and compared with those calculated from the KHBDC, AASHTO LRFD and Eurocode 3 provisions. Based on the comparison, the applicability of design equations in these specifications for the flexural strength of I-girder considering flange local buckling was evaluated.