• 제목/요약/키워드: SPME fiber type

검색결과 6건 처리시간 0.024초

Evaluation of Volatile Compounds Isolated from Pork Loin (Longissimus dorsi) as Affected by Fiber Type of Solid-phase Microextraction (SPME), Preheating and Storage Time

  • Park, Sung-Yong;Yoon, Young-Mo;Schilling, M. Wes;Chin, Koo-Bok
    • 한국축산식품학회지
    • /
    • 제29권5호
    • /
    • pp.579-589
    • /
    • 2009
  • This study was conducted to investigate the effects of heating, fiber type used in solid-phase microextraction (SPME, two phase vs three phase) and storage time on the volatile compounds of porcine M. longissimus dorsi (LD). Volatile compounds were measured using a gas chromatography and mass spectrometry (GC/MS) with a quadrupole mass analyzer. Among the volatile compounds identified, aldehydes (49.33%), alcohols (24.63%) and ketones (9.85%) were higher in pre-heated loins ($100^{\circ}C$/30 min), whereas, alcohols (34.33%), hydrocarbons (22.84%) and ketones (16.88%) were higher in non-heated loins. Heating of loins induced the formation of various volatile compounds such as aldehydes (hexanal) and alcohols. The total contents of hydrocarbons, alcohols, and carboxylic acids were higher in two phase fibers, whereas those of esters tended to be higher in three-phase fibers (p<0.05). Most volatile compounds increased (p<0.05) with increased storage time. Thus, the analysis of volatile compounds were affected by the fiber type, while heating and refrigerated storage of pork M. longissimus dorsi increased the volatile compounds derived from lipid oxidation and amino acid catabolism, respectively.

Analysis of Agrochemical Residues in Tobacco Using Solid Phase Microextraction-Gas Chromatography with Different Mass Spectrometric Techniques

  • Lee, Jeong-Min;Jang, Gi-Chul;Kim, Hyo-Keun;Hwang, Geon-Joong
    • 한국연초학회지
    • /
    • 제30권2호
    • /
    • pp.117-124
    • /
    • 2008
  • A solid phase microextraction (SPME) method in combination with gas chromatography/mass spectrometric techniques was used for the extraction and quantification of 12 selected agrochemical residues in tobacco. The parameters such as the type of SPME fiber, adsorption/desorption time and the extraction temperature affecting the precision and accuracy of the SPME method were investigated and optimized. Among three types of fibers investigated, polyacrylate (PA), polydimethylsiloxane (PDMS) and polydimethylsiloxane-divinylbenzene (PDMS-DVB), PDMS fiber was selected for the extractions of the agrochemicals. The SPME device was automated and on-line coupled to a gas chromatograph with a mass spectrometer. Mass spectrometry (MS) was used and two different instruments, a quadrupole MS and triple quadrupole MS-MS mode, were compared. The performances of the two GC-MS instruments were comparable in terms of linearity (in the range of 0.01$\sim$0.5 $\mu$g/mL) and sensitivity (limits of detection were in the low ng/mL range). The triple quadrupole MS-MS instrument gave better precision than that of quadrupole MS system, but generally the relative standard deviations for replicates were acceptable for both instruments (< 15%). The LODs was fully satisfied the requirements of the CORESTA GRL. Recoveries of 12 selected agrochemicals in tobacco yielded more than 80% and reproducibility was found to be better than 10% RSD so that SPME procedure could be applied to the quantitative analysis of agrochemical residues in tobacco.

Optimization of Headspace Sampling Using Solid Phase Microextraction For Volatile Organic Acids in Different Tobacco Types

  • Lee, Jang-Mi;Lee, Jeong-Min;Son, Seong-Ae;Kwon, Young-Ju;Jang, Gi-Chui;Kim, Young-Ho
    • 한국연초학회지
    • /
    • 제35권1호
    • /
    • pp.7-12
    • /
    • 2013
  • A Solid-phase micro extraction(SPME) was evaluated as a tool for headspace sampling of tobacco samples. Several experimental parameters (sampling temperature, pH, and type of SPME fibers) were optimized to improve sampling efficiency in two aspects ; maximum adsorption and selective adsorption of volatile organic acids onto SPME fibers. Among four types of SPME fibers such as PDMS(Polydimethylsiloxane), PA(Polyacrylate), Car/PDMS (Carboxen/Polydimethylsiioxane) and PDMS/DVB(Polydimethylsiioxane/Divinylbenzene) which were investigated to determine the selectivity and adsorption efficiency. A variety of tobacco samples such as flue cured, burley and oriental were used in this study. The effect of these parameters was often dominated by the physical and chemical nature (volatility, polarity) of target compounds. This method allowed us to make important improvements in selectivity and sensitivity. The Car/PDMS fiber was shown to be the most efficient at extracting the 10 selected volatile organic acids. The parameters were optimized: $80^{\circ}C$ adsorption temperature, 30 min of adsorption time, $240^{\circ}C$ desorption temperature, 1 min of adsorption time.

HS SPME-GC/MS를 이용한 혈액 중 유기염소계 농약의 분석법 개발 (Development of an analytical method of organochlorine pesticides in human bloods using head space-solid phase microextraction coupled with gas chromatography/mass spectrometry)

  • 강태우;표희수;홍종기
    • 분석과학
    • /
    • 제21권4호
    • /
    • pp.259-271
    • /
    • 2008
  • 혈액 내에 축적되어 있는 유기염소계 농약을 분석하기 위한 방법으로 기존에는 액체-액체 추출법과 고체상 추출법을 많이 사용하였으나 정제 및 많은 양의 시료 처리에 한계가 있다. 이를 극복하기 위한 방법으로 시료양이 적으며 간편한 고체상미량추출법을 사용하여 혈액 중 18종의 유기염소계 농약의 최적 추출법을 연구하였다. 흡착조건(fiber type, 흡착시간, 흡착온도, 염석효과)과 탈착조건(탈착시간, 탈착온도) 등 최적의 추출을 위해 여러 가지의 실험조건 등을 검토한 결과, fiber는 polyacrylate $85{\mu}m$, 흡착시간은 50분, 흡착온도는 $80^{\circ}C$, 염석효과는 NaCl 0.1 g, 탈착시간은 5분, 탈착온도는 $280^{\circ}C$에서 최적임을 확인하였다. 정확도, 정밀도 및 검출한계에 대한 타당성을 최적 실험조건에서 조사한 결과, 검출한계는 0.05~0.20 ng/mL, 정밀도는 5.59~13.39%, 정확도는 -0.5%~24.5%의 범위인 것으로 확인되었다.

추출방법에 따른 잎담배 종류별 휘발성 향기성분 특성비교 (Comparison of the volatile flavor compounds in different tobacco types by different extraction methods)

  • 이장미;이정민;이창국;복진영;황건중
    • 한국연초학회지
    • /
    • 제32권2호
    • /
    • pp.77-87
    • /
    • 2010
  • Traditional simultaneous distillation extraction(SDE) and solid-phase micro extraction(SPME) methods using GC/MS were compared for their effectiveness in the extraction of volatile flavor compounds from different tobacco leaves types(flue-cured, burley, oriental). The major volatile flavor compounds of flue-cured and burley tobacco were similar such as neophytadiene, solanone, megastigmatrienone isomers, ${\beta}$-damascenone and ${\beta}$-ionone. On the other hand, volatile flavor compounds such as norambreinolide, sclareolide were specifically identified in oriental tobacco. Each method was used to evaluate the responses of some analytes from real samples and standards in order to provide sensitivity comparisons between two techniques. Among three types of SPME fibers such as PDMS(Polydimethylsiloxane), PA(Polyacrylate) and PDMS/DVB (Polydimethylsiloxane/Divinylbenzene) which were investigated to determine the selectivity and adsorption efficiency, PDMS/DVB fiber was selected for the extractions of the volatile flavor compounds due to its effectiveness. The qualitative analysis showed that the total amount of volatile flavor compounds in SDE method(130 species) was much more than that in SPME method(85 species). SPME method was more efficient for all the highly volatile compounds than SDE method, but on the other hand, low-volatile compounds such as fatty acids or high-molecular hydrocabons were detected in SDE method. SPME method based on a short-time sampling can be adjusted to favor a selected group compounds in tobacco. Furthermore this results could be used to estimate the aroma characteristics of cigarette blending by using a different type of tobacco with more effectiveness and convenience.

Analysis of Breath from Diabetic Patients Based on a One-chip-type Sensor Array

  • Yu, Joon-Boo;Jang, Byoung Kuk;Byun, Hyung-Gi
    • 센서학회지
    • /
    • 제28권4호
    • /
    • pp.221-224
    • /
    • 2019
  • Based on the results of studies on acetone excretion in diabetic patients, a one - chip sensors array was fabricated by combining acetone-selective sensor materials and volatile-organic-compound sensitive sensor materials. An electonic-nose was implemented using a sensor array and confirmed selectivity for five gases. In this system, the excretion of diabetic patients and controls was sampled with solid phase microextraction fiber and transferred to the sensor array. Although the control and diabetic patients were distinct, several samples failed. In the control group, the results of blood tests were normal, but patients were highly obese. In addition, the gas chromatography mass spectrometry results for the subjects revealed chemicals that are external factors.