• 제목/요약/키워드: Safety-Related Controller

검색결과 46건 처리시간 0.023초

IEC 61508에 기반한 원자력 발전소용 안전 등급 제어기의 SIL 분석에 대한 사례연구 (A Case Study of SIL Analysis for Single Station Controller in Nuclear Power Plant Based on IEC 61508)

  • 김건명
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권3호
    • /
    • pp.231-237
    • /
    • 2016
  • Purpose: It is not easy to suggest a quantitative data related to safety analysis. The objective of this paper is to propose a method of Safety Integrity Level (SIL) analysis and to suggest a SIL analysis result for single station controller in nuclear power plant based on IEC 61508. Methods: The Failure Modes and Effects Diagnostic Analysis (FMEDA) and average probability of failure on demand (PFD) are used for SIL assessment. Results: A SIL of single station controller is evaluated 4 by a reliability analysis results and PFD. Conclusion: A SIL analysis method and result for single station controller based on IEC 61508 are proposed in this paper. It can applicable for a manufacturer data in safety-related system.

건설업 사고 발생원인 파악을 위한 사고 분석 모델 개발 (Development of Accident Cause Analysis Model for Construction Site)

  • 임원준;기정훈;성주현;박종일
    • 한국안전학회지
    • /
    • 제34권1호
    • /
    • pp.45-52
    • /
    • 2019
  • Accident analysis models were developed to improve the construction site safety and case studies was conducted. In 2016, 86% of fatality accidents occurred due to simple unsafe acts. Structure related accidents are less frequent than the non structure related causes, but the number of casualties per accident is two times higher than non structure one. In the view of risk perception, efforts should be given to reduce accidents caused by low frequency - high consequence structure related causes. In case of structure related accident, structural safety inspection and management (including quality), ground condition management / inspection technology, and provision of risk information delivery system in case of non structure related accident were proposed as a solution. In analysis of relationship between safety related stakeholder, the main problem were the lack of knowledge of controller and player, loss of control due to duplicated controls, lack of communication system of risk information, and relative position error of controller and player.

조직의 안전분위기가 항공교통관제사의 안전행동에 미치는 영향 (The Effect of organizational safety climate at Air Traffic controller's safety behavior)

  • 이효상;박진우
    • 한국항공운항학회지
    • /
    • 제27권1호
    • /
    • pp.10-19
    • /
    • 2019
  • As a domestic aviation industry has been growing continuously, the air traffic volume of en-route has increased rapidly to 2,300 a day. According to developing air navigation system including Performance Based Navigation(PBN), the manner of flights has diversified. Consequentially task of air traffic service has been increasing more and more and the organization of Air Traffic Service(ATC) established one Air traffic management Office(ATMO), extends to 3 Regional organization(Seoul, Busan, Jeju) and a number of air traffic controller exceeds 600. The purpose of this research is going to investigate the relationship between organization's safety climate and air traffic controller's safety behavior, In pursuing above, previous studies related to co-worker and supervisor's safety climate were examined for literature review. Based on this previous studies, research model was constructed. Hypothesis was verified by effect. Data from 209 samples was employed for final survey. The main results show that co-worker and supervisor's safety climate were meaningful factors to effect perceived Safety Behavior and safety knowledge, safety motivation were significantly and positive related to safety compliance.

Brake Controller 시험기를 이용한 GEC, VVVF 전동차 Brake Controller 점검방법 개선에 관한 연구 (Using Brake Controller Tester GEC, VVVF trains Study on the Improvement of Brake Controller Check)

  • 조태영;강범수;최재원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1358-1363
    • /
    • 2011
  • 본 연구에서는 GEC, VVVF 전동차 운전실에 취부 되어 있는 Brake Controller 점검방법 개선에 관한 연구를 수행하였다. Brake Controller내의 단동 스냅동작 스위치, 복동 스냅동작 스위치 및 단자대와 연결된 모든 부품을 개별적 점검이 아닌 현 전동차와 동일한 조건에서 전반적인 면밀한 검토 및 분석을 통하여 개선책을 강구하고, 고장을 사전에 발견해 처리함으로써 운행 장애 최소화 및 승객의 안전과 직결된 전동차 안전운행에 기여하고자 본 연구를 시작하였다.

  • PDF

안전등급 제어기 프로세서 모듈 가상화 (Virtualization of Safety-Related Controller Processor Module)

  • 이윤상;김종명;윤혁제;송승환;김정범
    • 한국전자통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.449-458
    • /
    • 2022
  • 발전소에는 사고에 대비하여 사고를 방지하거나, 사고 시 발전소의 안정적인 운영을 위하여 여러 단계의 검증을 거친 프로그램을 제어기에 설치하여 운영한다. 본 논문은 발전소 안전 제어 설비에 사용되는 제어기 프로세서에 대하여 검증 완료된 바이너리 형태의 운영체제 및 응용 프로그램이 동작할 수 있도록 가상화한 기술에 대해 기술하였다. 본 가상화 프로세서에 적용된 기술은 상용 Tool을 이용하여 명령어 해석기, 분석기 등 안전등급 제어기 프로세서 모듈 동작에 필수적인 구성 요소들을 구현하였으며, 가상화 플랫폼 개발은 Imperas Tool을 사용하여 Linux 기반의 운영체제에서 개발하였다. 또한, 구현된 가상 프로세서 모듈이 정상적으로 바이너리 형태의 명령을 해석하고 수행하는지 확인하였다.

철도시스템의 안전성 향상을 위한 주연산보드 구현 (Implementation of Main Computation Board for Safety Improvement of railway system)

  • 박주열;김효상;이준환;김봉택;정기석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1195-1201
    • /
    • 2011
  • Since the release of safety standard IEC 61508 which defines functional safety of electronic safety-related systems, SIL(Safety Integrity Level) certification for railway systems has gained lots of attention lately. In this paper, we propose a new design technique of the computer board for train control systems with high reliability and safety. The board is designed with TMR(Triple Modular Redundancy) using a certified SIL3 Texas Instrument(TI)'s TMS570 MCU(Micro-Controller Unit) to guarantee safety and reliability. TMR for the control device is implemented on FPGA(Field Programmable Gate Array) which integrates a comparator, a CAN(Controller Area Network) communication module, built-in self-error checking, error discriminant function to improve the reliability of the board. Even if a malfunction of a processing module occurs, the safety control function based on the proposed technique lets the system operate properly by detecting and masking the malfunction. An RTOS (Real Time Operation System) called FreeRTOS is ported on the board so that reliable and stable operation and convenient software development can be provided.

  • PDF

전자연동장치의 안전성 활동에 관한 연구(II) (A Study on Fault Tolerant Digital Controllers for Programmable Electronic Interlocking System(II))

  • 박재영;이종우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권12호
    • /
    • pp.667-673
    • /
    • 2006
  • Programmable electronic interlocking system plays key role in railway operation and is closely related to railway accidents, in which the programmable electronic controller of interlocking system may become sources. Redundant digital controllers are adopted as the interlocking controllers to prevent the accidents from the controllers being out of order. The redundant digital controllers being fault tolerant are realized through dual or triplex controllers. In this paper, we calculated safety and availability of the redundant digital controllers using Markov models, demonstrated key part to determine the availability ana the safety.

산업현장의 천장크레인 조작장치 사용 현황과 인간공학적 문제점 (Overhead Crane Controllers and Ergonomic Problems in Industrial Field)

  • 박재희;김승희
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.90-97
    • /
    • 2017
  • Overhead cranes are the most widely used and have been identified as one of the main causes of fatal accidents. Although structural, mechanical and electrical safety standards for overhead cranes have been established to some extent, ergonomic standards related to crane controllers are rarely established. As a result, many crane accidents are reported to be caused by operator's error. To investigate the actual use of crane controllers in the industrial field, we surveyed 82 overhead cranes in 15 workplace and interviewed workers operating them. This study has presented the ergonomic problems related to the crane controllers in the field. As a result of investigation, it was found that the direction control signs, the sign language, and the button layout on the pendant switches and remote controllers are not standardized, which can cause a human error. To reduce human errors in overhead crane operation, ergonomic standards for controllers should be reflected on the government legislation or standards.

다변량 공정관리 기술과 추세알고리즘의 연계에 관한 조사연구 (A Study on the Relation between Multivariate Process Control Techniques and Trend Algorithm)

  • 정해운
    • 대한안전경영과학회지
    • /
    • 제13권4호
    • /
    • pp.225-235
    • /
    • 2011
  • Autoregressed Controller, which have trend algorithm, seeks to minimize variability by transferring the output variable to the related process input variable, while multivariate process control techniques seek to reduce variability by detecting and eliminating assignable causes of variation. In the case of process control, a very reasonable objective is to try to minimize the variance of the output deviations from the target or set point. We also investigate algorithm with relevant Shewhart chart, Theoretical control charts, precontrol and process capability. To help the people who want to make the theoretical system, we compare the main techniques in "a study on the relation between multivariate process control techniques and trend algorithms".

정수기용 압축기의 안전성 평가 및 소손 패턴 분석에 관한 연구 (A Study on the Safety Assessment and Damage Pattern of Water Purifier Compressors)

  • 최충석
    • 한국안전학회지
    • /
    • 제28권2호
    • /
    • pp.21-25
    • /
    • 2013
  • The purpose of this study is to provide basic data for the safety assessment of a water purifier when water leaks due to inappropriate maintenance and the examination of the cause of accidents related to the leak. Due to its inspection and management by non-specialists, if a leak occurs in a water purifier with the water level controller being inclined, it may result in the failure of the compressor, power supply line, PCB, etc. The analysis of the thermal diffusion pattern of water purifier compressors using a thermal image camera shows that its maximum temperature was approximately $80^{\circ}C$. In addition, its operating current was a maximum of 13 A and the system's operating current was approximately 1.7 A after the compressor was charged. It was found that the housing type power cable cover of the compressor had the effect of preventing electric shock but has poor flame resistance. Furthermore, the performance of the overload protector, PTC relays, etc., was excellent but they have potential for problems as metallic terminals were exposed, resulting in the potential of a safety related accident. The terminals and their surface damaged by the tracking showed a trace of carbonization and the resistance between terminals was measured to be approximately $8{\Omega}$. In addition, while the tracking was proceeding, the fuse and circuit breaker installed for system protection did not operate.