• Title/Summary/Keyword: Sampling rate

Search Result 1,646, Processing Time 0.034 seconds

The Effect of Sampling Rate on Statistical Properties of Extreme Wave (파랑자료의 sampling rate가 극한파의 통계에 미치는 영향)

  • Kim, Do Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.1
    • /
    • pp.36-41
    • /
    • 2013
  • In this paper time series wave data are simulated using wave spectrum with random phases of the wave signal. The simulated wave signals are used to study the effect of the sampling rate on the ocean wave characteristics. Effect of sampling rate on wave data which include extreme wave such as freak waves are examined and various wave characteristics including abnormality index (AI), kurtosis of wave profile and maximum wave height are examined. Various wave heights are decreased as the sampling rate decreases. The zero-th moment of the wave spectrum does not affect much on the sampling rate but the second moment are greately affected on the sampling rate. The error due to the sampling rate is decreases as the wave period increases. The error in significant wave height based on the wave spectrum $H_s$ is smaller than that on the time domain method $H_{1/3}$. AI index and kurtosis of wave profile do not deviate much from the exact date as long as the sampling rate is greater than 1 Hz. Ocean wave measurement with the sampling frequency higher than 1 Hz will result the error less than 5% in estimating the height of extreme waves.

Construction of variable sampling rate model and its evaluation

  • Imoto, Fumio;Nakamura, Masatoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.106-111
    • /
    • 1994
  • We proposed a new variable sampling rate model which expresses the phenomena with both rapid and slow components. A method for determining the variable sampling rate and the older of the time series model was explained. The proposed variable sampling rate model was evaluated based oil an information criterion(AIC). Tile variable sampling rate model brought smaller an information criterion than one of a constant sampling rate model of conventional type, and was proved to be effective as a prediction model of the system with both rapid and slow components.

  • PDF

Choice of Efficient Sampling Rate for GNSS Signal Generation Simulators

  • Jinseon Son;Young-Jin Song;Subin Lee;Jong-Hoon Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.3
    • /
    • pp.237-244
    • /
    • 2023
  • A signal generation simulator is an economical and useful solution in Global Navigation Satellite System (GNSS) receiver design and testing. A software-defined radio approach is widely used both in receivers and simulators, and its flexible structure to adopt to new signals is ideally suited to the testing of a receiver and signal processing algorithm in the signal design phase of a new satellite-based navigation system before the deployment of satellites in space. The generation of highly accurate delayed sampled codes is essential for generating signals in the simulator, where its sampling rate should be chosen to satisfy constraints such as Nyquist criteria and integer and non-commensurate properties in order not to cause any distortion of original signals. A high sampling rate increases the accuracy of code delay, but decreases the computational efficiency as well, and vice versa. Therefore, the selected sampling rate should be as low as possible while maintaining a certain level of code delay accuracy. This paper presents the lower limits of the sampling rate for GNSS signal generation simulators. In the simulation, two distinct code generation methods depending on the sampling position are evaluated in terms of accuracy versus computational efficiency to show the lower limit of the sampling rate for several GNSS signals.

A Sampling Inspection Plan with Human Error: Considering the Relationship between Visual Inspection Time and Human Error Rate

  • Lee, Yong-Hwa;Hong, Seung-Kweon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.645-650
    • /
    • 2011
  • Objective: The aim of this study is to design a sampling inspection plan with human error which is changing according to inspection time. Background: Typical sampling inspection plans have been established typically based on an assumption of the perfect inspection without human error. However, most of all inspection tasks include human errors in the process of inspection. Therefore, a sampling inspection plan should be designed with consideration of imperfect inspection. Method: A model for single sampling inspection plans were proposed for the cases that visual inspection error rate is changing according to inspection time. Additionally, a sampling inspection plan for an optimal inspection time was proposed. In order to show an applied example of the proposed model, an experiment for visual inspection task was performed and the inspection error rates were measured according to the inspection time. Results: Inspection error rates changed according to inspection time. The inspection error rate could be reflected on the single sampling inspection plans for attribute. In particular, inspection error rate in an optimal inspection time may be used for a reasonable single sampling plan in a practical view. Conclusion: Human error rate in inspection tasks should be reflected on typical single sampling inspection plans. A sampling inspection plan with consideration of human error requires more sampling number than a typical sampling plan with perfect inspection. Application: The result of this research may help to determine more practical sampling inspection plan rather than typical one.

Development of an Evaluation Method for Flow Rate Performance of Particulate Sampling Pump using Three-pieces Cassette Holder Containing Filters (여과지가 장착된 3단 카세트를 이용한 입자상물질 채취용 펌프의 유량성능 평가방법)

  • Song, Ho-June;Kim, Nam-Hee;Kim, Ki-Youn;Ma, Hye-Lan;Lee, Kwang-Young;Jeong, Jee-Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.348-355
    • /
    • 2013
  • Objectives: In working environment measurement, sampling is an important stage for obtaining reliable result as analysis. A personal air sampling pump is one of the most fundamental and important element in the work environment measurement, but it remains at the level of calibrating the flow rate of the pump before and after sampling. There is no checking whether the flow rate set at the initial stage would be hold during sampling. The purpose of this study was to develop a method to evaluate the flow rate performance of particulate sampling pump with three-pieces cassette holder containing filters commonly used to sample particulate. Materials and methods: We tested back pressure of particulate sampling pumps commonly used in Korea with three-pieces cassette holder containing various filters, and tried to find out the combination conditions of filters in accordance with back pressure required by ISO standard 13137. Results: We found out the matrix of sampling media such as three-pieces cassette holder containing filters applicable to the pressure drop required by the ISO standard for evaluating the flow rate stability under increasing pressure drop and long term(8 hour) performance. Conclusions: This evaluation method using sampling media matrix for checking flow rate stability proposed by this study could be very useful tool to find out good performance pumps before sampling.

Design of Audio Sampling Rate Conversion Block (Audio Sampling Rate Conversion Block의 설계)

  • 정혜진;심윤정;이승준
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.827-830
    • /
    • 2003
  • This paper proposes an area-efficient FIR filter architecture for sampling rate conversion of hi-fi audio data. Sampling rate conversion(SRC) block converts audio data sampled at 96KHz down to 48KHz sampled data and vice versa. 63-tap FIR filter coefficients have been synthesized that gives 100dB stop band attenuation and 5.2KHz transition bandwidth. Time-shared filter architecture requires only one multiplier and accumulator for 63-tap filter operation. This results in huge hardware saving of up to 10~19 times smaller compared with traditional FIR structure.

  • PDF

An Effect of Sampling Rate to the Time and Frequency Domain Analysis of Pulse Rate Variability (샘플링율이 맥박변이도 시간 및 주파수 영역 분석에 미치는 영향)

  • Yang, Yoon La;Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1247-1251
    • /
    • 2016
  • This study aims to investigate the effect of sampling frequency to the time domain and frequency domain analysis of pulse rate variability (PRV). Typical time domain variables - AVNN, SDNN, SDSD, RMSSD, NN50 count and pNN50 - and frequency domain variables - VLF, LF, HF, LF/HF, Total Power, nLF and nHF - were derived from 7 down-sampled (250 Hz, 100 Hz, 50 Hz, 25 Hz, 20 Hz, 15 Hz, 10 Hz) PRVs and compared with the result of heart rate variability of 10 kHz-sampled electrocardiogram. Result showed that every variable of time domain analysis of PRV was significant at 25 Hz or higher sampling frequency. Also, in frequency domain analysis, every variable of PRV was significant at 15 Hz or higher sampling frequency.

Adaptive Sampling for ECG Detection Based on Compression Dictionary

  • Yuan, Zhongyun;Kim, Jong Hak;Cho, Jun Dong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.608-616
    • /
    • 2013
  • This paper presents an adaptive sampling method for electrocardiogram (ECG) signal detection. First, by employing the strings matching process with compression dictionary, we recognize each segment of ECG with different characteristics. Then, based on the non-uniform sampling strategy, the sampling rate is determined adaptively. As the results of simulation indicated, our approach reconstructed the ECG signal at an optimized sampling rate with the guarantee of ECG integrity. Compared with the existing adaptive sampling technique, our approach acquires an ECG signal at a 30% lower sampling rate. Finally, the experiment exhibits its superiority in terms of energy efficiency and memory capacity performance.

Standardization of Sample Handling Methods to Reduce the Rate of Inadequate Sampling

  • Yo-Han Seo
    • Quality Improvement in Health Care
    • /
    • v.29 no.2
    • /
    • pp.85-93
    • /
    • 2023
  • Purpose: The predominant approach for mitigating inadequate sampling rates has primarily involved bolstering the volume of education. This study aimed to curtail inadequate sampling rates through the implementation of continuous quality improvement (CQI) activities, tailoring effective methods to the unique needs of each institution. Methods: We developed a sample handling guidebook and implemented QI activities to address this issue. Results: These measures resulted in a 4.7% decrease in inadequate sampling rates, concurrently improving knowledge of sample handling and overall nurse satisfaction. We addressed the root causes of inadequate sampling before laboratory pre-processing by: 1) focusing on systematic rather than erratic errors through CQI activities, 2) revising the sample handling guide, and 3) delivering face-to-face education based on the specific needs of the nursing department. These changes resulted in an additional 0.6% decrease in the inadequate sampling rate. Conclusion: This study demonstrates that the implementation of CQI activities based on evidence derived from a multifaceted causal analysis significantly reduced the inadequate sampling rate compared to previous studies.