Equivalent Circuit Analysis of Single Phase Induction Motor Considering Magnetic Saturation Characteristics (자기포화 특성을 고려한 단상유도전동기의 등가회로 해석)

  • Kim, Young Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.270-277
    • /
    • 2013
  • Single phase induction motor(SPIM) is used widely because it is driven by single phase source. However, the efficiency of the motor is not good due to saturation of magnetic material. To analyze the motor accurately, the magnetic saturation characteristics should be considered in analysis of equivalent circuit. In this paper, lumped parameter of circuit are derived from multi phase induction motor using method of symmetrical coordinates. Also, we presents a method for the equivalent circuit analysis of SPIM using magnetic saturation rate. The magnetic nonlinearity is considered deriving magnetizing reactance from voltage-current saturation curve. As a results, current characteristic, torque, output and efficiency are shown through analysis of equivalent circuit. A simulation results of SPIM will be used to improve the characteristics and efficiency of motor.

Saturation Prediction for Crowdsensing Based Smart Parking System

  • Kim, Mihui;Yun, Junhyeok
    • Journal of Information Processing Systems
    • /
    • v.15 no.6
    • /
    • pp.1335-1349
    • /
    • 2019
  • Crowdsensing technologies can improve the efficiency of smart parking system in comparison with present sensor based smart parking system because of low install price and no restriction caused by sensor installation. A lot of sensing data is necessary to predict parking lot saturation in real-time. However in real world, it is hard to reach the required number of sensing data. In this paper, we model a saturation predication combining a time-based prediction model and a sensing data-based prediction model. The time-based model predicts saturation in aspects of parking lot location and time. The sensing data-based model predicts the degree of saturation of the parking lot with high accuracy based on the degree of saturation predicted from the first model, the saturation information in the sensing data, and the number of parking spaces in the sensing data. We perform prediction model learning with real sensing data gathered from a specific parking lot. We also evaluate the performance of the predictive model and show its efficiency and feasibility.

Loss Minimization Control of Interior Permanent Magnet Synchronous Motors Considering Self-Saturation and Cross-Saturation

  • Pairo, Hamidreza;Khanzade, Mohammad;Shoulaie, Abbas
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1099-1110
    • /
    • 2018
  • In this paper, a loss minimization control method for interior permanent magnet synchronous motors is presented with considering self-saturation and cross saturation. According to variation of the d-axis and q-axis inductances by different values of the d-axis and q-axis components of currents, it is necessary to consider self-saturation and cross saturation in the loss minimization control method. In addition, the iron loss resistance variation due to frequency variation is considered in the condition of loss minimization. Furthermore, the loss minimization control method is compared with maximum torque per ampere (MTPA), unity power factor (UPF) and $i_d=0$ control methods. Experimental results verify the performance and proper dynamic response of the loss minimization control method with considering self-saturation and cross saturation.

불포화 자연토의 포화도에 따른 동전기 정화특성에 관한 실험적 연구

  • 김병일;김익현;김기년;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.302-305
    • /
    • 2003
  • The electrokinetic remediation tests for natural soil contaminated by lead are performed on unsaturated conditions, in which the degree of saturation is controlled through the changes in water content and the constant unit weight. At the degree of saturation of 70% the small acid range and electrical potential is developed. The changes in the water content are little above the saturation of 90%. But it is increased by 1.7 times at the degree of saturation of 70%. Finally, the efficiency of extraction is improved at 70% than 100%.

  • PDF

Standstill Identification of Magnetic Flux Saturation Model Including Cross-Saturation for Synchronous Motors (상호 포화를 포함한 자기저항 동기 전동기의 자속 포화 모델에 대한 정지 상태 추정 기법)

  • Woo, Tae-gyeom;Park, Sang-woo;Choi, Seung-Cheol;Yoon, Young-Doo;Lee, Hak-Jun;Hong, Chanook;Lee, Jeongjoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.364-371
    • /
    • 2021
  • A magnetic flux saturation model of Synchronous Reluctance Motors (SynRMs) and a parameter estimation method are proposed at standstill. The proposed magnetic flux model includes the nonlinear relationship between the current and the magnetic flux for self-saturation and cross-saturation. Voltage is injected at standstill to estimate the magnetic flux saturation model. Voltages are injected into the d-axis and q-axis to obtain data on self-saturation. Subsequently, voltages are simultaneously injected into the d-q axis to obtain data on cross-saturation. On the basis of the measured current and the calculated magnetic flux, the parameters of the proposed model are estimated using the least square method (LSM). Simulation and experiment were performed on a 1.5-kW SynRM to verify the proposed method. The proposed model can be used to create a high-efficiency operation table, a sensorless algorithm, and a current controller to improve the control performance of a motor.

Effect for Eefficiency of Variable Speed Control of Magnetic Saturation in Induction Machine (유도전동기의 자기적 포화가 가변속 제어의 효율에 미치는 영향)

  • Jeong, Jong-Ho;Yun, Seo-Jin;Lee, Eun-Woong;Moon, Jae-Yun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.52-54
    • /
    • 1998
  • In this paper, analytically presented the magnetic saturation impact on the efficiency of induction motor. Especially, in this study concerned with various cases such as included magnetic saturation, constant flux.

  • PDF

Saturation Characteristics of a Boron-lined ionization Chamber

  • Chae, Sung-Ki
    • Nuclear Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.94-102
    • /
    • 1973
  • Saturation characteristics of a current-type ionization chamber are investigated theoretically and experimentally in the columnar recombination region. The experiments were performed using a boron-lined cylindrical ionization chamber filled with nitrogen or helium at pressures of 760 mmHg and 380 mmHg. The collection efficiency deduced from the analytical method is in good agreement with the experimental results. This theory makes it possible to predict saturation characteristics for all ionization intensities with only the design data.

  • PDF

A Study on Design of Linear Motor for Maglev for High Efficiency (자기부상열차 추진용 리니어모터 효율향상 설계연구)

  • Kim, Youn-Hyun;Kim, Ki-Chan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.561-566
    • /
    • 2016
  • In this paper, effective design method of linear induction motor(LIM) for Maglev is proposed in order to maximize system efficiency of Maglev. For the high system efficiency of Maglev, it is important to minimize weight of traction motor. Light weight design by changing materials of core and winding is conducted without changing volume of LIM. For the silicon steel core of primary part for magnetic flux path, iron-cobalt alloy steel with high magnetic saturation characteristic compared to silicon steel is suggested. Moreover, aluminium winding with light weight instead of copper winding is wounded in the widen slot area due to the high magnetic saturation level. For the verification of performance of proposed model, the characteristics are analyzed by using finite element method(FEM).

Experimental Study on the Characteristics of CO2 Capture with Spray Towers Using Ammonia Solution (암모니아수 흡수제를 사용하는 분무탑의 이산화탄소 포집 기본특성에 관한 실험적 연구)

  • Lim, Youngbok;Choi, Munkyoung;Lee, Jinwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.2
    • /
    • pp.165-172
    • /
    • 2014
  • Experiments were conducted to identify basic characteristics of $CO_2$ capture using a spray tower with a single nozzle. Results were evaluated in terms of $CO_2$ saturation which is the main determining factor of regeneration energy, and capture efficiency under various operating conditions. Changes in the capture efficiency under various conditions are well expressed as a monotone increasing function of the relative solvent $(NH_3):CO_2$ flow rate. Although changes in $CO_2$ saturation are also well described as a function of the $NH_3/CO_2$ flow rate ratio, these are expressed as a monotone decreasing function, in contrast with the increasing function of $CO_2$ efficiency. In recent research on the relationship between $CO_2$ saturation and capture efficiency, $CO_2$ saturation was found to decrease when capture efficiency increased. In conclusion, the results show that the amount of solvent used for achieving high capture efficiencies is excessive, as is the amount of regeneration energy needed.

A Study on the Stability of Supervisory Control for Nonlinear System with Saturating Input (포화입력을 가진 비선형 시스템에 대한 슈퍼바이저 제어의 안정성 연구)

  • 차경래
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.112-122
    • /
    • 1999
  • In realistic control systems the nonlinear saturation attributes of the control actuator due to physical limitations should be taken into account This nonlinear saturation of actuators may cause not only deterioration of the control performance but also a large overshoot during start-up and shut-down. As the overshoot increases the system may become oscillatory unstable. in this paper the supervisor implementation which guarantees good performance for saturation operation and prevents reset wind up is presented, Moreover the sufficient conditions of the stability for saturated system using supervisory control with a dynamic controller are provided in the continuous-time and in the discrete-time domain Numerical example is illustrated to depict the efficiency of supervisory control for a typical satuaurated production-distribution system controlled by a discrete-time dynamic controller and to validate basic results by simulation.

  • PDF