• Title/Summary/Keyword: Sealing integrity

Search Result 20, Processing Time 0.034 seconds

Sealing Integrity of polymeric ZnO Surge Arresters (고분자 피뢰기의 기밀특성에 관한 연구)

  • Liang, He-Jin;Han, Se-Won;Cho, Han-Goo;Kim, In-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.258-261
    • /
    • 1997
  • The sealing integrity is related to the safe operation of arrester the prime failure reason of porcelain housed arresters is moisture ingress. To be a meaningful tests a polymer arrester sealing test must be a realistic acceleration of field service. We think the test should be an accelerating course of actual temperatures, the enduring property to mechanical load and temperatures should be considered together. A union test method consisting of the thermal mechanical test and thermal cycling test is proposed to test the sealing integrity of polymeric arresters, which uses dielectric loss, leakage current 1mA DC voltage and partial discharge as the diagnostic techniques, and the test results were presented. The comparison states that the TMTCUT method is suitable fur the test of sealing integrity of polymeric arresters. .

  • PDF

Effect of Thermal Mechanical Stresses on Electrical Characteristics of Polymer Housed Surge Arresters (열-기계적 스트레스가 폴리머 피뢰기의 전기적 특성에 미치는 영향)

  • Cho, Han-Goo;You, Dae-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.6
    • /
    • pp.555-560
    • /
    • 2007
  • This paper describes the results of a study on the sealing integrity of polymer housed surge arrester based on the thermal mechanical test. The polymer housed surge arrester employs silicone insulating materials for its housing, instead of the conventional porcelain housing. The polymer housed surge arresters exhibited the highest sealing integrity because it is not air volume between the FRP(fiber reinforced plastics) module and the silicone housing. In accordance, the sealing integrity of station class surge arresters is investigated with moisture ingress test. And, the influence of sealing integrity was evaluated through such as measurement of the deflection, reference voltage, leakage current. In electrical characteristics, reference voltage decreased in the range of $16.45{\sim}16.15\;kV$ with after thermal mechanical test. In contrary, despite the continued moisture ingress, the polymer housed surge arresters exhibited almost the same leakage current value and the resistive leakage current has risen slightly. As a results, It was thought that the polymer housed surge arresters shows good stability with sealing integrity.

Reliability Evaluation of Polymer Arrester with Sealing Integrity for Station and Substation (발.변전용 폴리머 피뢰기의 기밀특성에 따른 신뢰성 평가)

  • Yoo, Dae-Hoon;Lee, Un-Yong;Cho, Han-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.326-327
    • /
    • 2006
  • The paper describes the development of arrester for 154kV class power station and substation. The arrester employs silicone insulating materials for Its housing, instead of the conventional porcelain housing. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters for ultra high voltage is investigated with moisture ingress test. The diagnostic techniques are discusses, including watt loss, partial discharge, AC leakage current, 1mA DC voltage and residual voltage.

  • PDF

Temperature and Leakage Current Characteristics of Polymeric Surge Arrester with Housing (폴리머 피뢰기의 구조에 따른 온도와 누설전류 특성)

  • Cho, Han-Goo;You, Dae-Hoon;Lee, Un-Yong;Kim, Ha-Na
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.3
    • /
    • pp.273-280
    • /
    • 2007
  • In this paper, the ZnO surge arrester performance of power distribution class has been studied under different manufacturing conditions such as housing materials(polymeric, porcelain), interface sealants and one-body molding type. In the recent years, the polymeric ZnO surge arresters have been developed and put into operations based on their excellent characteristics. For polymeric surge arresters, the inner gas volume is extremely small, especially in solid insulation polymeric arresters there are not any gas volume inside arresters in the structure due to polymeric materials are filled into the internal gas volume. The sealing integrity is related to safe operation of surge arrester, the prime failure reason of porcelain housed arresters is moisture ingress. In this paper, the sealing integrity of polymeric surge arresters is investigated with moisture multi-aging test and ingress test. The evaluation techniques are used to inspect the sealing integrity of polymeric arresters, including leakage current, surface temperature, reference voltage and dissipation factor.

Performance of Sealing Integrity and Banding strain of HV Polymeric bushing with Thermal Mechanical Test (열-기계적 시험에 따른 초고압 폴리머 부싱의 굽힘변형 및 기밀성능에 관한 연구)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Kang, Hyung-Kyung;Lee, Chul-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1441_1441
    • /
    • 2009
  • This paper describes performance of sealing integrity and bending strain of HV polymeric bushing with thermal mechanical test. Generally the properties of FRP tube can be influenced by the winding angle, wall thickness and winding tension. As a results, multi winding bushing shows that it has max deflection in the range of 16.5~16.9 mm.

  • PDF

Evaluation of Long-term Performance of Metal Seal Through Accelerated Test (가속화 시험을 통한 금속 밀봉재 장기성능 평가)

  • Choi, Woo-seok;Lim, Jongmin;Yang, Yun-young;Cho, Sang Soon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.237-245
    • /
    • 2020
  • Metal seals are the main components that establish the containment boundary in bolted casks, which store spent nuclear fuel. These seals are degraded by heat and radiation. In addition, creep occurs when the seals are exposed to intense heat for an extended period. This creep results in the stress relaxation of the seals, which consequently impairs the seal integrity. The stress relaxation can reduce the sealing performance of the metal seal, which can further cause leakage in the storage cask. Moreover, the reduction of bolt tension leads to sealing performance degradation. In this study, the results of high-temperature-accelerated tests were obtained to evaluate the containment integrity of metal seals and the decrease in bolt tension. During the tests, the leakage rate, bolt strain, and ambient temperature of the metal seals were measured and analyzed. The metal seals were found to maintain containment integrity for 50 years of storage. The validity of the acceleration test was also investigated.

Current Status of SOFC Materials and Processing Core Technology (고체산화물 연료전지 소재공정 요소기술 개발 현황)

  • Lee, Jong-Ho;Son, Jiwon;Kim, Heryong;Kim, Byong-Kook;Lee, Hae-Weon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.123.1-123.1
    • /
    • 2010
  • The solid oxide fuel cell (SOFC) has attracted great deal of attention due to its high electrical efficiency, high waste-heat utilization, fuel flexibility, and application versatility. However, SOFC technology is still not matured enough to fulfill the practical requirements for commercialization. Therefore, all the research and development activities are mainly focused on a development of practically viable SOFCs with higher performance and better reliability. We were successful in fabricating high-performance anode-supported unit cells by employing hierarchically controlled multi-layered electrodes for both structural reliability and high performance. In addition, a novel composite sealing gasket made it possible to achieve excellent sealing integrity even with considerable surface irregularities in a multi-cell planar arrayed stack.

  • PDF

Structural Integrity Evaluation for the Reactor Coolant Pump Shaft Seal Assembly (원자로냉각재펌프 축밀봉장치에 대한 구조적 건전성 평가)

  • Kim, Minsu;Kim, Minchul;Kim, Oaksug;Chung, Sungho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.2
    • /
    • pp.44-50
    • /
    • 2017
  • The shaft seal of the reactor coolant pump is installed on the upper side of the rotating shaft of the pump to seal the reactor coolant from flowing out between the rotating shaft and the non-rotating parts. In this study, the loading conditions for the normal operation and faulted conditions are identified and structural integrity evaluation is performed using the finite element stress analysis for the sealing apparatus of the APR 1400 reactor coolant pump. It is confirmed that the stress analysis results satisfy the design criteria at all loading conditions.

Integrity Evaluation of Ice Plugged Pipes Applied on Short Jacket

  • Park, Yeong-Don;Son, Geum-Su
    • Nuclear Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.105-116
    • /
    • 2002
  • In special industrial fields such 3s nuclear power plants and chemical plants, it is often necessary to repair system components without plant shutdown or drainage of system having many piping structures which may have hazardous or expensive fluid. A temporary ice plugging method for blocking internal flow is considered as a useful method in that case. According to the pipe freezing guideline of the nuclear power plant, the length of a freezing jacket must be longer than twice of the pipe diameter. However, for applying the ice plugging to short pipes which do not have enough freezing length because of geometrical configuration, it is inevitable to use shorter jacket less than twice of the pipe diameter. In this study, the integrity evaluation for short pipes in the nuclear power plant Is conducted by an experiment and the finite element analysis. From the results, the ice plugging process in short pipes can be safely carried out without any plastic deformation and fracture.

SOFC 밀봉재로서 $SiO_2-B_2O_3-RO$계에서 RO 변화에 따른 밀봉특성

  • Gwon, Yong-Jin;Choe, Byeong-Hyeon;Ji, Mi-Jeong;An, Yong-Tae;Seol, Gwang-Hui;Nam, San
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.33.2-33.2
    • /
    • 2011
  • 고온형 SOFC의 개발에 있어 스택의 신뢰성을 확보하는데 가장 중요한 핵심기술은 스택 구성요소 사이를 접합하는데 필요한 고온형 밀봉재의 개발이다. SOFC 스택에서의 밀봉재는 고체전해질과 접속자 사이에서 음극에 공급되는 연료가스와 양극에 공급되는 공기가 서로 혼합되는 것을 방지하는 역할은 물론 기계적으로 취약한 단전지의 보호 및 스택전체 구조물의 구조적 일체성(Structural integrity)을 부여하는데 주목적이 있다. 현재 기체 기밀성을 유지하기 위한 밀봉재는 크게 유리 및 결정화 유리계, mica및 mica/유리복합재료, 유리/충전재 복합재료 등이 사용되고 있으나 다수의 단위전지로 구성되는 스택 구성에서 스택의 열기계적 안정성 및 장기수명을 보장하기 위해서는 본 연구에서 개발하고자 하는 복합밀봉재가 가장 적합할 것으로 예상되고 있다. 본 연구에서는 $SiO_2-B_2O_3-RO$계에 BaO, SrO를 일정비율로 첨가하여 제작된 유리 frit을 열처리하여 물리화학적 물성변화를 검토하였으며, $700^{\circ}C$ 이하의 연화점을 갖는 유리를 기지상으로 하고 세라믹 보강재를 첨가한 고온형 복합밀봉재를 개발하고 그 물리화학적 안정성, 열기계적 안정성 및 밀봉 특성을 평가하였다.

  • PDF