• Title/Summary/Keyword: Self Capacitive

Search Result 32, Processing Time 0.033 seconds

Multi-touch Recognition and Tracking for Self Capacitive TSP (자기정전용량 방식의 TSP에서 멀티터치 인식 및 추적)

  • Jung, Sung Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.2
    • /
    • pp.136-140
    • /
    • 2014
  • This paper introduces a multi-touch recognition and tracking method for self capacitive TSP(Touch Screen Pannel). Self capacitive TSP recognizes finger touches by sensing capacitive change of ITO transparent conducting film arranged by rows and columns on the TSP pannel. They have some advantages such as high SNR, fast sensing, and simple touch processing, but have very difficulties for multi-touch processing. This disadvantage makes that the mutual capacitive TSPs, which have no such disadvantage, have been more widely used especially for multi-touch applications. However, since the other applications for remote control pad or recently developed wearable devises have only restrictive requirements for multi-touch, the disadvantage of self capacitive TSP is not a critical problem. In this paper, we first describe multi-touch recognition problems in self capacitive TSP and then propose how to overcome those problems and a tracking method of two touches when they are moving. Experimental results of our method showed that our algorithm works well in two touches.

Frequency Response Compensation Technique for Capacitive Microresonator (용량형 마이크로 공진기의 주파수 응답 보상 기법)

  • Seo, Jin-Deok;Lim, Kyo-Muk;Ko, Hyoung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.235-239
    • /
    • 2012
  • This paper presents frequency response compensation technique, and a self-oscillation circuit for capacitive microresonator with the compensation technique using programmable capacitor array, to compensate for the frequency response distorted by parasitic capacitances, and to obtain stable oscillation condition. The parasitic capacitances between the actuation input port and capacitive output port distort the frequency response of the microresonator. The distorted non-ideal frequency response can be compensated using two programmable capacitor arrays, which are connected between anti-phased actuation input port and capacitive output port. The simulation model includes the whole microresonator system, which consists of mechanical structure, transimpedance amplifier with automatic gain control, actuation driver and compensation circuit. The compensation operation and oscillation output of the system is verified with the simulation results.

1.5 V Sub-mW CMOS Interface Circuit for Capacitive Sensor Applications in Ubiquitous Sensor Networks

  • Lee, Sung-Sik;Lee, Ah-Ra;Je, Chang-Han;Lee, Myung-Lae;Hwang, Gunn;Choi, Chang-Auck
    • ETRI Journal
    • /
    • v.30 no.5
    • /
    • pp.644-652
    • /
    • 2008
  • In this paper, a low-power CMOS interface circuit is designed and demonstrated for capacitive sensor applications, which is implemented using a standard 0.35-${\mu}m$ CMOS logic technology. To achieve low-power performance, the low-voltage capacitance-to-pulse-width converter based on a self-reset operation at a supply voltage of 1.5 V is designed and incorporated into a new interface circuit. Moreover, the external pulse signal for the reset operation is made unnecessary by the employment of the self-reset operation. At a low supply voltage of 1.5 V, the new circuit requires a total power consumption of 0.47 mW with ultra-low power dissipation of 157 ${\mu}W$ of the interface-circuit core. These results demonstrate that the new interface circuit with self-reset operation successfully reduces power consumption. In addition, a prototype wireless sensor-module with the proposed circuit is successfully implemented for practical applications. Consequently, the new CMOS interface circuit can be used for the sensor applications in ubiquitous sensor networks, where low-power performance is essential.

  • PDF

A Small Monopole Antenna with Novel Impedance Matching Structure (새로운 임피던스 매칭 구조를 가지는 소형 모노폴 안테나)

  • Kim, Dong-Jin;Min, Kyeong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.7
    • /
    • pp.828-833
    • /
    • 2007
  • A small monopole antenna with a novel impedance matching structure is proposed in this paper. The proposed antenna is designed for W-LAN(IEEE 802.11b). The antenna design concept is based on a ${\lambda}/8$ folded monopole antenna with a self-impedance matching structure. The size of the proposed antenna is smaller than the resonant length, thus the impedance at the terminal of the antenna becomes very capacitive. To compensate fur this impedance mismatching, the proposed antenna employs a novel self-impedance matching structure. The self-impedance matching structure is located on the top of the antenna; it improves the impedance matching and ultimately the efficiency of the antenna. The measured results of the proposed antenna show reasonable agreement with prediction.

Capacitive Humidity Sensor Using Reactive Methacrylate Copolymers (반응성이 있는 메타크릴레이트 공중합체를 이용한 정전용량형 습도센서)

  • 공명선;이임렬
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.4
    • /
    • pp.21-27
    • /
    • 2003
  • The copolymers with various composition of methyl methacrylate (MMA), ethyl methacrylate (EMA), methacrylic acid (MA) and hydroxyethyl methacrylate (HEMA) were synthesized for capacitive humidity sensitive materials. The capacitive humidity sensor consisted of a polymethacrylate film coated on both sides with gold electrode. Capacitance versus relative humidity increased with HEMA content in the copolymer. In the case of self-crosslinkable MMA/MA/HEHA= 40/10/10, the average capacitance at 30%RH, 60%RH and 90%RH are 102, 134 and 166 pF, respectively. And also, the hysteresis, temperature cycle and long-term stability were evaluated as a capacitance humidity sensor.

  • PDF

A High Resolution Capacitive Single-Silicon Microaccelerometer using High Amplitude Sense Voltage for Application to Personal Information System (고 감지 전압을 이용한 개인 정보기기용 고정도 정전용량형 단결성 실리콘 가속도계)

  • Han, Ki-Ho;Cho, Young-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.53-58
    • /
    • 2001
  • This paper presents a high resolution capacitive microaccelerometer for applications to personal information systems. We reduce the mechanical noise level of the microaccelerometer by increasing the proof-mass based on deep RIE process. We reduce the electrical noise level by increasing the amplitude of an AC sense voltage. The high sense voltage is obtained by DC-to-DC voltage multiplier. In order to solve the nonlinearity problem caused by the high sense voltage, we modify the conventional comb electrode of straight finger type into that of branched finger type, resulting in self force-balancing effects for enhanced detection linearity. The proposed branched finger capacitive microaccelerometer was fabricated by the deep RIE process of an SOI wafer. The fabricated microaccelerometer reduces the electrical noise at the level of $2.4{\mu}g/\sqrt{Hz}$ for the sense voltage of l6.5V, which is 10.1 times smaller than the electrical noise level of $24.3{\mu}g/\sqrt{Hz}$ at 0.9V. For the sense voltage higher than 2V, the electrical noise level of the microaccelerometer became smaller than the constant mechanical noise level of $11{\mu}g/\sqrt{Hz}$. Total noise level, including the electrical noise and the mechanical noise, has been measured as $9{\mu}g/\sqrt{Hz}$ for the sense voltage of 16.5V, which is 3.2 times smaller than the total noise of $28.6{\mu}g/\sqrt{Hz}$ for the sense voltage of 0.9V. The self force-balancing effect results in the increased stiffness of 1.98 N/m at the sense voltage of 17.8V, compared to the stiffness of 1.35 N/m at 0V, thereby generating the additional stiffness at the rate of $0.002N/m/V^{2}$.

  • PDF

Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System (패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극)

  • Lee, Jeong Su;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

Low Actuation Voltage Capacitive Shunt RF-MEMS Switch Using a Corrugated Bridge with HRS MEMS Package

  • Song Yo-Tak;Lee Hai-Young;Esashi Masayoshi
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.2
    • /
    • pp.135-145
    • /
    • 2006
  • This paper presents the theory, design, fabrication and characterization of the novel low actuation voltage capacitive shunt RF-MEMS switch using a corrugated membrane with HRS MEMS packaging. Analytical analyses and experimental results have been carried out to derive algebraic expressions for the mechanical actuation mechanics of corrugated membrane for a low residual stress. It is shown that the residual stress of both types of corrugated and flat membranes can be modeled with the help of a mechanics theory. The residual stress in corrugated membranes is calculated using a geometrical model and is confirmed by finite element method(FEM) analysis and experimental results. The corrugated electrostatic actuated bridge is suspended over a concave structure of CPW, with sputtered nickel(Ni) as the structural material for the bridge and gold for CPW line, fabricated on high-resistivity silicon(HRS) substrate. The corrugated switch on concave structure requires lower actuation voltage than the flat switch on planar structure in various thickness bridges. The residual stress is very low by corrugating both ends of the bridge on concave structure. The residual stress of the bridge material and structure is critical to lower the actuation voltage. The Self-alignment HRS MEMS package of the RF-MEMS switch with a $15{\Omega}{\cdot}cm$ lightly-doped Si chip carrier also shows no parasitic leakage resonances and is verified as an effective packaging solution for the low cost and high performance coplanar MMICs.

High-resolution Capacitive Microaccelerometers using Branched finger Electrodes with High-Amplitude Sense Voltage (고감지전압 및 가지전극을 이용한 고정도 정전용량형 미소가속도계)

  • 한기호;조영호
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • This paper presents a navigation garde capacitive microaccelerometer, whose low-noise high-resolution detection capability is achieved by a new electrode design based on a high-amplitude anti-phase sense voltage. We reduce the mechanical noise of the microaccelerometer to the level of 5.5$\mu\textrm{g}$/(equation omitted) by increasing the proof-mass based on deep RIE process of an SOI wafer. We reduce the electrical noise as low as 0.6$\mu\textrm{g}$/(equation omitted) by using an anti-phase high-amplitude square-wave sense voltage of 19V. The nonlinearity problem caused by the high-amplitude sense voltage is solved by a new electrode design of branched finger type. Combined use of the branched finger electrode and high-amplitude sense voltage generates self force-balancing effects, resulting in an 140% increase of the bandwidth from 726㎐ to 1,734㎐. For a fixed sense voltage of 10V, the total noise is measured as 2.6$\mu\textrm{g}$/(equation omitted) at the air pressure of 3.9torr, which is the 51% of the total noise of 5.1$\mu\textrm{g}$/(equation omitted) at the atmospheric pressure. From the excitation test using 1g, 10㎐ sinusoidal acceleration, the signal-to-noise ratio of the fabricated microaccelerometer is measured as 105㏈, which is equivalent to the noise level of 5.7$\mu\textrm{g}$/(equation omitted). The sensitivity and linearity of the branched finger capacitive microaccelerometer are measured as 0.638V/g and 0.044%, respectively.

Development of New Algorithm for the Analysis of Self-Excitation in Primary Restorative Transmission Systems (시송전 계통에서 자기여자 현상의 새로운 해석 알고리즘 개발)

  • Park S.M.;Lee K.S.;Bai J.C.;Hwang B.H.;Song I.J.;Lee N.H.;Lee H.J.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.3
    • /
    • pp.117-121
    • /
    • 2005
  • Power system restoration following a massive blackout starts with re-energizing primary transmission lines at first. Some factors such as Ferranti effect, and line charging reactive power should be considered in this stage. Severe overvoltage may be induced by the Ferranti effect at the lines since it would be usually no load condition. And lack of capacitive reactive power will cause the self-excitation. This paper presents a new precise algorithm to analyze the primary restorative transmission system focused on the two major static overvoltage problems during the early restoration process.