• Title/Summary/Keyword: Semi anechoic chamber

Search Result 39, Processing Time 0.026 seconds

A Study on the Evaluation of Semi-Anechoic Chamber Characteristics (전파반무향실의 특성평가에 관한 연구)

  • 김민석;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.21 no.4
    • /
    • pp.29-38
    • /
    • 1997
  • Because of the result of a large use of electronic equipments, the occupation density of microwave frequency band is highly increased, and electromagnetic environment is getting more seriously bad. It is sometimes reported that electronic machines are not normally operated on account of the influence of undesired electromagnetic wave, which often gives fatal blow to even human life and thus becomes serious social problems. OATS(Open Area Test Site) is principally used to measure EMI or examine elelctromagnetic emission. Because of various restrictions we often build semi-anechoic chamber which has the function of OATS to measure EMI or EMS other than OATS. If the difference of the site attenuation between semi-anechoic chamber and OATS is within ${\pm}3dB$, the semi-anechoic chamber is recognized as adequate facility to measure EMI or EMS. Accordingly authors evaluate and analyze site attenuation due to absorbent materials, polarization, mutual coupling effects, etc. The calculated and the measured site attenuation in semi-anechoic chamber are compared. As a result good agreement is obtained.

  • PDF

Quiet Zone Implementation for VHF Antenna Measurement in Semi-Anechoic Chamber (반무반사실내 VHF 대역 안테나 측정환경 구현)

  • Moon, Jung-Ick
    • Journal of IKEEE
    • /
    • v.16 no.4
    • /
    • pp.290-296
    • /
    • 2012
  • In this study, an effective echo-suppression and cancellation technique using reflectors in semi-anechoic chamber and time-domain measurement is proposed. By using the proposed technique, the uniformity of electric field in QZ(Quiet Zone) could be improved and the antenna test environments similar to the fully anechoic chamber could be accomplished. The performances of the proposed test environments is verified with the simulated and measured data. And it is demonstrated that this test environment is possible to use the measuring the radiational characteristics of a small antenna in VHF band.

Evaluation of the Characteristics of Semi-Anechoic Chamber for the Vertical Polarization (전파발무향심의 수직편파에 대한 특성평가)

  • 김동일;정세모;김민석
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.3
    • /
    • pp.107-115
    • /
    • 1996
  • With the rapid advance of electronic equipments and the frequent, use of them, the electromagnetic environments including EMC or EMI problems are very complicated. The radiation of electromagnetic waves from electronic equipments has strictly been controlled by the authorities concerned from many years ago. Though it is the most proper to test EMI or EMC in the open area test site, we have used the anechoic chamber in place of the test site because of its various restrictions. To achieve the purpose, in this paper, the performances of a few anechoic chambers according to absorbing materials are analyzed for horizontal and vertical polarizations respectively. Furthermore, the calculated and the measured site attenuations in semi-anechoic chamber made with ferrite grid are compared. The obtained results are to be valuable for designing an anechoic chamber.

  • PDF

Passby Noise Prediction in Semi-anechoic Chamber (반무향실내에서의 가속 주행 소음 예측 방법)

  • 박순홍;김양한;고병식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.162-172
    • /
    • 1997
  • We investigated passby noise measurement method in a small-sized semi-anechoic chamber satisfying the American based SAE J1470 Recommended Practice to facilitate the measurements. We have tired two passby noise prediction methods. One is line array microphone method in which the free space sound field is decomposed into its eigenfunctions in the spherical coordinates and rearranged according to the order of the spherical Hankel function. However, due to the characteristics of the spherical Hankel function, it is impossible to distinguish the function's characteristics according to the order in farfield. Consequently it can be applied in the transient region of the nearfield and the farfield. The other method is nearfield acoustic holography(NAH). Although measuring hologram for the several operational engine speeds by conventional scanning method is time-consuming work, we can greatly reduce the measuring time by selecting the appropriate engine speed through preexperimental knowledge. To verify this method we experimented with the outdoor passby noise measurements and the passby noise prediction in the small-sized semi-anechoic chamber for the identical passenger vehicle and obtained reasonable and acceptable results.

  • PDF

Site attenuation of the KRISS semi-anechoic chamber for vertical polarization (KRISS 전자파 반무향실의 수직편파 시험장감쇠량)

  • 강태원;정연춘;정낙삼
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.3 no.1
    • /
    • pp.28-32
    • /
    • 1992
  • The site attenuation for vertical polarization was theoretically calculated using EMF(electro- Motive force) method and measured for 3-m method in the KRISS semi-anechoic chamber. Agreement within .+-. 4 dB has been obtained between measured and calculated values in the frequency range of 30 MHz to 1000 MHz except 250 MHz and around 100 MHz.

  • PDF

Comparison of Correlation Algorithms between GTEM Cell and Semi-Anechoic Chamber (GTEM 셀과 전자파 반-무반사실 사이의 상관관계 알고리즘 비교.분석)

  • 권종화;이애경;최형도
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.2
    • /
    • pp.188-195
    • /
    • 2002
  • This paper statistically verifies two correlation algorithms by comparing the data of GTEM cell to those of semi-anechoic chamber (SAC). Correlation algorithms considered in this paper are 3 and 15 position methods, which simulate the EMI test for an equipment under test (EUT) over the ground plane by using the radiated power from EUT located within GTEM cell. Also, the results obtained by two algorithms are compared with the theoretical values calculated from an ideal dipole model. From the results, it was found that the data obtained by two correlation algorithms and SAC have a strong correlation. In addition, the EMI data by 3 position method showed higher than those by 15 position method and SAC measurements.

Electromagnetic Immunity Test Environments of Advanced Vehicles with Radar Sensor Systems (첨단자동차의 전자파 내성 실험 환경에 관한 연구: 레이더 센서를 중심으로)

  • Kim, Sungbum;Ryu, Jiil;Woo, Hyungu;Yong, Boojoong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.4
    • /
    • pp.50-56
    • /
    • 2019
  • Recently, automobile industries have developed ADAS, smart cars, connected cars, automated driving systems, which use a variety of sensor systems - ultrasonics, cameras, lidars and radars - and communication systems. It is necessary to examine the electromagnetic immunity of vehicles equipped with those systems. The electromagnetic immunity tests are carried out in an electromagnetic semi anechoic chamber, which is cut off from the outside. It is difficult to create test environments in which the radar sensor systems of vehicles work properly in the test chamber. In this study, test jigs were designed and tested and as a result they are shown to be effective to create test environments for electromagnetic immunity tests of vehicles equipped with radar sensors. We also proposed additional safety standards for immunity tests of vehicles with radar systems that currently do not exist.

Electromagnetic Immunity Test Environments of Advanced Vehicles with Camera Sensor Systems (첨단자동차의 전자파 내성 실험 환경에 관한 연구: 카메라 센서를 중심으로)

  • Woo, Hyungu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.4
    • /
    • pp.7-12
    • /
    • 2020
  • Recently, automobile industries have developed ADAS, smart cars, connected cars, automated driving systems, which use a variety of sensor systems - ultrasonics, cameras, lidars and radars - and communication systems. It is necessary to examine the electromagnetic immunity of vehicles equipped with the sensor systems due to the fact that the normal operation of those systems is very important to the safety of the vehicles. The electromagnetic immunity tests are carried out in an electromagnetic semi anechoic chamber, which is cut off from the outside. It is difficult to create test environments in which the camera sensor systems of vehicles work properly in the test chamber. In this study, test jigs were designed and tested and as a result they are shown to be effective to create test environments for electromagnetic immunity tests of vehicles equipped with camera sensors. We also proposed additional safety standards for immunity tests of vehicles with camera systems that currently do not exist.

Electromagnetic Immunity Test Environments of Advanced Vehicles with Communication Systems (첨단자동차의 전자파 내성 실험 환경에 관한 연구: 외부통신 장치를 중심으로)

  • Woo, Hyungu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.1
    • /
    • pp.14-19
    • /
    • 2022
  • Recently, automobile industries have developed ADAS, smart cars, connected cars, automated driving systems, which communicate with outsides of a vehicle not only in uni-directional way but also in bi-directional way. It is necessary to examine the electromagnetic immunity of vehicles equipped with those communication systems. The electromagnetic immunity tests are carried out in an electromagnetic semi anechoic chamber, which is cut off from the outside electromagnetically. In this study, additional test environments were designed and tested and as a result they are shown to be effective to create test environments in an experimental chamber for electromagnetic immunity tests of vehicles equipped with communication systems.

A Study on the Evaluation of Semi-Anechoic Chamber Characteristics -mainly on horizontal polarization- (전파반무향실의 특성평가에 관한 연구 - 수평편파를 중심으로 -)

  • 김동일;김민석
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.1
    • /
    • pp.9-16
    • /
    • 1995
  • We are confronted with the serious EMI(electromagnetic interference) problems in company with the development of electronic equipments. Accordingly it is also required to construct some anechoic chambers for EMI measurement. Furthermore it is very important to evaluate the chamber characteristics in advance of its construction. For that purpose we have analyzed the characteristics by computer simulation in base on the image method, and compared the results with the measured ones. In case of 3-meter method as a result, the curved line of height pattern of open site varies similarly as that of height pattern of anechoic chamber. When we measure the electromagnetic strength and can get the height pattern curves by frequencies, we utilized it effectively because we can protect instrumental errors in measurement. On the other hand, there is a little difference in site attenuation above 700MHz. When the ferrite grid was used however, the calculated values agree well with the measured values up to 1000MHz with the exception of 30-40 MHz range. The reason is that we don't consider the antenna coupling in the low frequencies of 30-100MHz range.

  • PDF