• Title/Summary/Keyword: Semi-closed compartment

Search Result 4, Processing Time 0.021 seconds

Effects of Change in Heat Release Rate on Unsteady Fire Characteristics in a Semi-Closed Compartment (반밀폐된 구획에서 발열량 변화에 따른 비정상 화재특성)

  • Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.75-83
    • /
    • 2012
  • An experimental study was conducted to investigate the effects of change in heat release rate on unsteady fire characteristics of under-ventilated fire in a semi-closed compartment. A standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time using a spray nozzle located at the center of enclosure. Temperature, heat flux, species concentrations and heat release rate were continuously measured and then global equivalence ratio (GER) concept was adopted to represent the unsteady thermal and chemical characteristics inside the compartment. It was observed that there was a significant difference in unsteady behavior between global and local combustion efficiency, and the GERs predicted by ideal and measured heat release rate were also shown different results in time. The unsteady behaviors of temperature, heat flux and species concentrations were represented well using the GER concept. It was important to note that CO concentration was gradually decreased with the increase in GER after reaching its maximum value in the range of 2.0~3.0 of global equivalence ratio. In addition, the experimental data on unsteady thermal and chemical behaviors obtained in a semi-closed compartment will be usefully used to validate a realistic fire simulation.

Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room (반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 2012
  • The objective of this study is to evaluate the prediction accuracy of FDS(Fire Dynamic Simulator) for the thermal and chemical characteristics of under-ventilated fire with unsteady fire growth in a semi-closed compartment. To this end, a standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time (until maximum 2.0 MW based on ideal heat release rate) using a spray nozzle located at the center of enclosure. To verify the capability of FDS, the predicted results were compared with a previous experimental data under the identical fire conditions. It was observed that with an appropriate grid system, the numerically predicted temperature and heat flux inside the compartment showed reasonable agreement with the experimental data. On the other hand, there were considerable limitations to predict accurately the unsteady behaviors of CO and $CO_2$ concentration under the condition of continuous fire growth. These results leaded to a discrepancy between the present evaluation of FDS and the previous evaluation conducted for steady-state under-ventilated fires. It was important to note that the prediction of transient CO production characteristics using FDS was approached carefully for the under-ventilated fire in a semi-closed compartment.

An Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed Compartment (반밀폐된 구획에서 비정상 화재특성 예측을 위한 FDS의 평가)

  • Hwang, Cheol-Hong;Mun, Sun-Yeo;Park, Chung-Hwa;Kim, Jong-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.3-6
    • /
    • 2011
  • 비정상(unsteady) 화재성장이 발생되는 반밀폐된 구획에서 환기부족화재의 열 및 화학적 특성에 관한 FDS(Fire Dynamics Simulator)의 예측성능 평가가 수행되었다. 이를 위해 실규모 ISO 9705 표준 화재실의 출입구 폭이 0.1m로 축소되었으며, spray 노즐을 통해 Heptane 연료유량은 선형적으로 증가되었다. 수치계산에 대한 신뢰도 확보를 위하여 동일조건에서 수행된 실험결과와의 상세한 비교가 이루어졌다. 적절한 격자계를 이용한 FDS의 결과는 구획 내부의 온도 및 열유속(heat flux)은 비교적 잘 예측하지만, 비정상 CO 및 $CO_2$ 생성특성은 적절히 예측하지 못함을 확인하였다. 이러한 결과는 최근 수행된 유사조건의 정상상태 환기부족 구획화재에 대한 FDS 예측결과와 상반된 것으로서, 반밀폐된 구획화재 모델링에서 FDS를 이용한 비정상 CO 생성특성 예측에 상당한 주위가 요구됨을 확인하였다.

  • PDF

Measurement of $\textrm{CO}_2$ Concentration and Leaf Area Index for Crop Photosynthesis Model in Sweet Pepper (단고추의 작물 광합성 모델을 위한 $\textrm{CO}_2$ 농도와 엽면적지 수 측정)

  • Lee, Beom-Seon;Chung, Soon-Ju;Jang, Hong-Gi
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.192-201
    • /
    • 1999
  • This study was aimed to introduce the measurement of $CO_2$ concentration and leaf area index in the phytotron for predicting the effect of CO.E, light and leaf area index on the instantaneous photosynthetic rate of sweet pepper with the existing ASKAM model. Measurements were made in 2 semi-closed phytotron compartments in which three different $CO_2$ concentrations were applied at random. Plants were grown on containers with circulating nutrient solution at 21$^{\circ}C$ and 80-95% relative humidity. The model estimates crop net $CO_2$ uptake for short time intervals during the day based on short-term data of daily radiation, temperature and $CO_2$ concentration. During the photosynthesis measurements, $CO_2$ concentrations in both compartments and in the basement were measured every minute. This was also done for the flow of pure $CO_2$ into the compartment, global radiation, photosynthetic active radiation inside the compartment, temperature and relative humidity. Crop growth models summarize our knowledge on crop behavior and have as such a wide range of applications in analysis, crop management and thus as a farm management tool.