• Title/Summary/Keyword: Septic tank

Search Result 68, Processing Time 0.023 seconds

An Experimental Investigation for Efficient Operation of Septic Tank (정화조의 효율적인 운영을 위한 실험적 고찰)

  • Lee, Jang-Hown;Lee, Kyeong-Soo;Kho, Soo-Hoon;Song, Min-Hee;Lee, Soo-Hyun;Lee, Yong-Hoon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.123-129
    • /
    • 2012
  • A septic tank is a purification treatment system where night soil and other waste matter is converted into harmless material by the activities of bacteria. Effluent from the septic tank flows into the sewer pipe, and then this effluent affects the quality of water environment and makes foul smell. In this study, through the proper maintenance of septic tank it was tried to minimize the impact of sewer pipe on water quality and fouling smell. BOD removal rate from the septic tank's effluent which exceeded legal cleaning period was investigated for the proper maintenance. BOD Removal rate of the twelve septic tank's effluent is -62.5% to 43.9%. According to the result of BOD removal rate, septic tank cleaning should be done at least once a year. And the pathogenic coliform bacillus in the twelve septic tank's effluent is average 768,000 (MPN/$100m{\ell}$). The chlorine disinfection is needed to remove the pathogenic coliform bacillus in septic tank effluent.

Recycling of a discarded septic tank as a rainwater management system and it's economic feasibility analysis (폐정화조를 재활용한 다목적 빗물관리시스템 구상 및 경제성 분석)

  • Kim, Mikyeong;Kwak, Donggeun;Han, Mooyoung;Yang, Jichung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.647-654
    • /
    • 2009
  • Since the end of the 1990s, sewer pipe improvement works have been going on: most septic tanks have been thrown away and discarded. These discarded septic tanks amounts up to 370,000 based on the project plan 2005-2008: it is a serious squander of nation's resources, a contaminating means that buries toxins under soil, and a cause of a expensive waste. Research on recycling of discarded septic tank as a new resource is in urgent need. This research suggests plans to recycle discarded septic tank as a rainwater management facility, solutions to water cycle recovery in the limelight, and economic analysis of the plan. In the case of a recycling discarded septic tank as a rainwater management facility will socially benefit to support economical adequacy, discard cost saving of septic tank and water supply and sewage cost reduction will come out. Consequently a rainwater management facility converted from a discarded septic tank leads to decentralization of the rainwater management system, which anticipates a positive effect on recovery of urban water cycle.

Studies on the Contamination Degree of Effluent from the Sewage Purification System and Septic Tank (오수정화시설 및 정화조 방류수의 수질오염도에 관한 연구)

  • 어수미;이홍근
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.35-40
    • /
    • 1991
  • This study was performed to investigate the contamination degree of effluent from the sewage purification system and septic tank. The 711 samples, were collected from the large size tank located in Seoul from Mar. to June 1991. The results were as follows 1. The pH values of effluent were largely neutral of 6.96 in sewage and 7.43 in septic tank. 2. The average concentration of BOD was 48.18 mg/l in sewage and 127.0 rng/l in septic tank. 3. The average concentration of SS was 40.8mg/l in sewage and 90.5rng/l in septic tank. 4. In the analysis of nutrient salts, the average concentration of NH$_{3}$-N was 31.62mg/l in sewage and 88.79 mg/l in septic tank. 5. In the analysis of correlation among items, BOD, SS, NH$_{3}$-N and PO$_{4}$-P were higly correlated beween items. 6. As a results of above analysis, it is considered as desirable evaluation method of effluent not through the only item but through the integrated items.

  • PDF

An Analysis on the Effect of Improvement of Rural Three Septic Tank Privy - in point of helminthes - (三槽式農村便所 改良의 效果에 관한 分析 -기생충으라 중심으로-)

  • Han, Don Hee
    • Journal of Environmental Health Sciences
    • /
    • v.11 no.2
    • /
    • pp.29-39
    • /
    • 1985
  • This experimental study was carried out to evaluate the improvement of rural privys and to develop the system of the three septic tank privy. For this study, 42 samples of excreta, 42 samples of soil and 26 samples of vegetables were drawn out of the conventional privys while 26samples of excreta, 26samples of soil and 26samples of vegetables out of the three septic tank privys from five villages in Chun Song County. Kang Won Province for the period from 22th August to 13th October, 1984. The major findings are as follows : 1. Positive cases of helminthes are found 41 out of 42(97.6%) excreta of the conventional privys whereas those from the three septic tank privys are found 2 out of 26 (7.7%). Average numbers of helminthes from the excreta of the conventional privys are 4.4 whereas those from the three septic tank privys are 1.1. 2. Positive cases of helminthes are found 33 out of 42 (78.6%) soil of the conventional privys whereas those from the three septic tank privys are found 20 out of 26(76.9%). However, this difference does not reveal statistical significance (P>0.01). Average numbers of helminthes from the soil of the conventional privys are 2.3 whereas those from the three septic tank privys are 1.7 and the difference in total number of helminthes reveals statistical significance (P<0.05). 3. Positive cases of helminthes from vegetable samples drawn out of the conventional privys are found 13 out of 26(50.0%) whereas those froin the three septic tank ptivys are found 10 out of 26(38.5%). Average numbers of helminthes from vegetable samples drawn out of the conventional privys are 1.1 whereas those from the three septic tank privys are 0.7. However, these differences in both positive rates and total numbers of helminthes do not reveal statistical significance (P>0.05).

  • PDF

Development of Combined Septic Tank for Middle-Small Scale Sewage Treatment (중·소규모 생활오수 처리를 위한 합병정화조 개발)

  • Rim, Jay-Myoung;Han, Dong-Joon
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.73-77
    • /
    • 1997
  • This study aims to develop the combined septic tank for middle-small scale sewage treatment. The developed process were circular and separate type. The circular combined septic tank was controlled sludge discharge and could be modified the advanced treatment system. The separate combined septic tank was could be applicated wastewater that discharge flow was varied, and was could be maintained F/M ratio constantly. The optimum hydraulic retention time was about 16 hours.

  • PDF

Development of Optimal Septic Tank in the Countries of Water Shortages (물 부족국가에서 활용가능한 정화조의 최적모형 개발)

  • Lim, Bong-Su;Jing, Hai-Long
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.418-427
    • /
    • 2015
  • This study was carried out to evaluate the performance of a lab-scale novel septic tank system for improving the conventional septic tank in the developing countries of water shortages. The lab-scale novel septic tank system consists of sepetic tank, aeration tank with HBC-ring, and sand filter. Optimum HRT was reguired about 1.5days to get a total COD removal efficiency of 90%, COD, BOD and SS removal efficiency was about 70%, 60%, and 85% in sepetic tank only. The structure of sepetic tank with two stages results in the high removal efficiency of organic matter. When sepetic tank, aeration tank, and sand filter were more than HRT 1.5days, 18hrs, and 12hrs, respectively, final effluent was less than 20 mg/L of BOD, 14 mg/L of SS, so that there is a high potential of its use for reusing water in flush toilet. There is no significant effect of HRT change on nutrient removal. Total nitrogen removal efficiency was about 40%, final effluent was 30~40 mg/L of TN, total phosphorus removal efficiency was about 11~25%, final effluent was 9~12 mg/L of TP. Because there is very small amounts of organic nitrogen and phosphorus in effluent, it was possible to reuse water for agricultural use.

Evaluation of the Septic Tank Performance in the Sewage Treatment Area and Suggestion of an Optimum Model (하수처리구역내 단독정화조의 성능평가 및 최적 모형의 제안)

  • Lim, Bong-Su;Jung, Keum-Hee;Wang, Ze-Jie
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.403-409
    • /
    • 2007
  • This study was carried out to recommend the systematic improving practice for the effective operation of septic tank, and the evaluation of its BOD and nutrient removal efficiency depending on process, the survey of characteristics of FRP material, and the suggestion of optimum septic tank model within sewage treatment area. The average BOD concentration and BOD removal efficiency of septic tank which was carried out the cleaning periodically in 63.9 mg/L and 77.8%, shows good quality better than the septic tank which was not carried out the cleaning regularly. Maximum load of tensile, flexural and compressive strength increased in proportion to its thickness, and the contents standard 25% of glass fiber required upgrade over than 30%. Configuration and performance for the optimum of the septic tank suggests that over $0.75m^3$ of the effective total volume, adding to over $0.25m^3$ a man for more than 5 men of the treated person, retention time should be within one day. Improving plans about facility and materials quality of the septic tank have an obligation that protective wall ought to install on the concrete bottom and side faces to prevent crumble or transform from loading of the ground or upper part of the structure on the tank setting. And it is eliminated the uneffective resisting pressure and it keeps off circulate imperfect products by strengthening of the test methods such as stretching strength, pressing strength, glass fiber contents and thickness.

Improvement of Septic Tank for Piggery Wastewater Treatment of Small Pig Farm (소규모 농가용 가축 뇨.오수 정화조 개선에 관한 연구)

  • 전병수;곽정훈;김태일;유용희;양창범;김형호;한정대
    • Journal of Animal Environmental Science
    • /
    • v.5 no.3
    • /
    • pp.175-180
    • /
    • 1999
  • This study was carried out to improve septic tank for piggery wastewater treatment of small pig farm. Septic tank were consisted of screen tank, aeration tank with two steps, settling tank, and filtering tank. Aeration tanks were filled with ALC of ø4~5cm. All operation steps were performed by timer from influent to effluent. Septic tank decreased BOD by 94.7% from 4,298.3mg/$\ell$ to 226.3mg/$\ell$ and also decreased SS by 92.4%, from 2,231.3mg/$\ell$ to 161.0mg/$\ell$, respectively.

Parametric Analysis on Ultimate Behavior of Cylindrical GFRP Septic Tank (원통형 GFRP 개인하수 처리시설의 극한거동에 대한 매개변수해석)

  • Kim, Sung Bo;Cho, Kwang Je
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1337-1347
    • /
    • 2013
  • The parametric analysis on ultimate behavior of buried cylindrical GFRP(Glass Fiber Reinforced Polymer) septic tank was presented. Two kinds of F.E. analysis model(soil-spring model and 3D full model) was constructed. The ultimate behavior of septic tank was investigated according to the size of stiffened steel ring and properties of underground soil. Ramberg-Osgood model and Druker-Prager model were used for material nonlinear characteristics of GFRP septic tank and soil, respectively. The diameter and thickness of stiffened steel ring inside septic tank, elastic modulus and internal friction angle of soil were selected for parametric variables. The ultimate behavior of septic tank, load-displacement, axial and hoop strain, were calculated and investigated.

Small Sewage Treatment Using Septic Tank and Sand Trench (부패조와 모래트렌치를 이용한 소규모 오수 처리)

  • 박영식
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • This study was carried out to treat sewage using sand trench combined with septic tank process in rural areas. In order to find optimum parameters, design and operation mode was changed from Run 1 to Run 4. In order to facilitate nitrification and T-P removal, diffuser and iron plate was installed in the 3rd trench of Run 2 period. The septic tank played a role as pre-application process of sand trench system. The removal efficiencies of COD, NH$_4$-N, T-P at steady state were 94.6%, 87.9% and 54.5%, respectively. Addition of diffuser and iron plate in the 3rd trench has increased the removal efficiencies of the NIL-N and T-P. In this system, denitrification were not occurred because of the high DO.